Drive indicator codes
View all Dell PowerEdge R750xa manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 184 highlights
Table 58. DC PSU status indicator codes (continued) Power indicator codes Condition same power rating. This results in a PSU mismatch condition, or failure to power on the system. CAUTION: If two PSUs are used, they must be of the same type and have the same maximum output power. CAUTION: When correcting a PSU mismatch, replace the PSU with the blinking indicator. Swapping the PSU to make a matched pair can result in an error condition and an unexpected system shutdown. To change from a High Output configuration to a Low Output configuration or conversely, you must power off the system. CAUTION: Combining AC and DC PSUs is not supported. Drive indicator codes The LEDs on the drive carrier indicate the state of each drive. Each drive carrier has two LEDs: an activity LED (green) and a status LED (bicolor, green/amber). The activity LED blinks whenever the drive is accessed. Figure 186. Drive indicators on the drive and the mid drive tray backplane 1. Drive activity LED indicator 2. Drive status LED indicator 3. Drive capacity label NOTE: If the drive is in the Advanced Host Controller Interface (AHCI) mode, the status LED indicator does not power on. NOTE: Drive status indicator behavior is managed by Storage Spaces Direct. Not all drive status indicators may be used. Table 59. Drive indicator codes Drive status indicator code Blinks green twice per second Off Condition Indicates that the drive is being identified or preparing for removal. Indicates that the drive is ready for removal. 184 System diagnostics and indicator codes