HP 6125XLG R2306-HP 6125XLG Blade Switch Network Management and Monitoring Com - Page 107

snmp-agent trap enable, Usage guidelines, Examples, Related commands, Syntax, Default, Views

Page 107 highlights

Usage guidelines SNMPv1 and SNMPv2c settings are supported only in non-FIPS mode. You can specify multiple SNMP notification target hosts. Make sure the SNMP agent uses the same UDP port for SNMP notifications as the target host. Typically, NMSs, for example, IMC and MIB Browser, use port 162 for SNMP notifications as defined in the SNMP protocols. If none of the keywords v1, v2c, or v3 is specified, SNMPv1 is used. Make sure the SNMP agent uses the same SNMP version as the target host so the host can receive the notification. If neither authentication nor privacy is specified, the security model is no authentication, no privacy. Examples # Configure the SNMP agent to send SNMPv1 traps to 10.1.1.1 in the community public. system-view [Sysname] snmp-agent trap enable standard [Sysname] snmp-agent target-host trap address udp-domain 10.1.1.1 params securityname public v1 Related commands • snmp-agent source • snmp-agent trap enable • snmp-agent trap life snmp-agent trap enable Use snmp-agent trap enable to enable SNMP notifications globally. Use undo snmp-agent trap enable to disable SNMP notifications globally. Syntax snmp-agent trap enable [ bgp | configuration | ospf [ authentication-failure | bad-packet | config-error | grhelper-status-change | grrestarter-status-change | if-state-change | lsa-maxage | lsa-originate | lsdb-approaching-overflow | lsdb-overflow | neighbor-state-change | nssatranslator-status-change | retransmit | virt-authentication-failure | virt-bad-packet | virt-config-error | virt-retransmit | virtgrhelper-status-change | virtif-state-change | virtneighbor-state-change ] * | standard [ authentication | coldstart | linkdown | linkup | warmstart ] * | system ] undo snmp-agent trap enable [ bgp | configuration | ospf [ authentication-failure | bad-packet | config-error | grhelper-status-change | grrestarter-status-change | if-state-change | lsa-maxage | lsa-originate | lsdb-approaching-overflow | lsdb-overflow | neighbor-state-change | nssatranslator-status-change | retransmit | virt-authentication-failure | virt-bad-packet | virt-config-error | virt-retransmit | virtgrhelper-status-change | virtif-state-change | virtneighbor-state-change ] * | standard [ authentication | coldstart | linkdown | linkup | warmstart ] * | system ] Default SNMP notifications are enabled for every module. Views System view 105

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207

105
Usage guidelines
SNMPv1 and SNMPv2c settings are supported only in non-FIPS mode.
You can specify multiple SNMP notification target hosts.
Make sure the SNMP agent uses the same UDP port for SNMP notifications as the target host. Typically,
NMSs, for example, IMC and MIB Browser, use port 162 for SNMP notifications as defined in the SNMP
protocols.
If none of the keywords
v1
,
v2c
, or
v3
is specified, SNMPv1 is used. Make sure the SNMP agent uses the
same SNMP version as the target host so the host can receive the notification.
If neither
authentication
nor
privacy
is specified, the security model is no authentication, no privacy.
Examples
# Configure the SNMP agent to send SNMPv1 traps to 10.1.1.1 in the community
public
.
<Sysname> system-view
[Sysname] snmp-agent trap enable standard
[Sysname] snmp-agent target-host trap address udp-domain 10.1.1.1 params securityname
public v1
Related commands
snmp-agent
source
snmp-agent
trap
enable
snmp-agent
trap
life
snmp-agent trap enable
Use
snmp-agent trap enable
to enable SNMP notifications globally.
Use
undo snmp-agent trap enable
to disable SNMP notifications globally.
Syntax
snmp-agent
trap
enable
[
bgp
|
configuration
|
ospf
[
authentication-failure
|
bad-packet
|
config-error
|
grhelper-status-change
|
grrestarter-status-change
|
if-state-change
|
lsa-maxage
|
lsa-originate
|
lsdb-approaching-overflow
|
lsdb-overflow
|
neighbor-state-change
|
nssatranslator-status-change
|
retransmit
|
virt-authentication-failure
|
virt-bad-packet
|
virt-config-error
|
virt-retransmit
|
virtgrhelper-status-change
|
virtif-state-change
|
virtneighbor-state-change
] * |
standard
[
authentication
|
coldstart
|
linkdown
|
linkup
|
warmstart
]
* |
system
]
undo
snmp-agent
trap
enable
[
bgp
|
configuration
|
ospf
[
authentication-failure
|
bad-packet
|
config-error
|
grhelper-status-change
|
grrestarter-status-change
|
if-state-change
|
lsa-maxage
|
lsa-originate
|
lsdb-approaching-overflow
|
lsdb-overflow
|
neighbor-state-change
|
nssatranslator-status-change
|
retransmit
|
virt-authentication-failure
|
virt-bad-packet
|
virt-config-error
|
virt-retransmit
|
virtgrhelper-status-change
|
virtif-state-change
|
virtneighbor-state-change
] * |
standard
[
authentication
|
coldstart
|
linkdown
|
linkup
|
warmstart
]
* |
system
]
Default
SNMP notifications are enabled for every module.
Views
System view