HP 6125XLG R2306-HP 6125XLG Blade Switch Network Management and Monitoring Com - Page 23
Table 8, Command output, The clock source is valid, which means the clock source
View all HP 6125XLG manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 23 highlights
Reference clock ID: 127.127.1.0 VPN instance: Not specified Local mode: client, local poll interval: 6 Peer mode: server, peer poll interval: 6 Offset: 0.2862ms, roundtrip delay: 3.2653ms, dispersion: 4.5166ms Root roundtrip delay: 0.0000ms, root dispersion: 10.910ms Reachabilities:31, sync distance: 0.0194 Precision: 2^18, version: 3, source interface: Not specified Reftime: d17cbba5.1473de1e Tue, May 17 2011 9:17:25.079 Orgtime: 00000000.00000000 Thu, Feb 7 2036 6:28:16.000 Rcvtime: d17cbbc0.b1959a30 Tue, May 17 2011 9:17:52.693 Xmttime: d17cbbc0.b1959a30 Tue, May 17 2011 9:17:52.693 Roundtrip delay samples: 0.007 0.010 0.006 0.011 0.010 0.005 0.007 0.003 Offset samples: 5629.55 3913.76 5247.27 6526.92 31.99 148.72 38.27 0.29 Filter order: 7 5 2 6 0 4 1 3 Total sessions: 1 Table 8 Command output Field Clock source Clock stratum Clock status Description IP address of the NTP server. Stratum level of the NTP server, which determines the clock accuracy. The value is in the range of 1 to 16. A lower stratum level represents greater clock accuracy. A stratum 16 clock is not synchronized and cannot be used as a reference clock. Status of the clock source corresponding to this association: • configured-The association was created by a configuration command. • dynamic-The association is established dynamically. • master-The clock source is the primary reference source of the current system. • selected-The clock source has survived the clock selection algorithm. • candidate-The clock source is the candidate reference source. • sane-The clock source has passed the sane authentication. • insane-The clock source has failed the sane authentication. • valid-The clock source is valid, which means the clock source meets the following requirements: it has passed authentication and is being synchronized. Its stratum level is valid, and its root delay and root dispersion values are within their ranges. • invalid-The clock source is invalid. • unsynced-The clock source has not been synchronized or the value of the stratum level is invalid. 21