Displaying iSCSI Optimization Information,
View all Dell PowerEdge XL 5133-4 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 167 highlights
Displaying iSCSI Optimization Information Use the show commands in Table 11-2 to display information on iSCSI optimization. Table 11-2. Displaying iSCSI Optimization Information Command show iscsi (Figure 11-2) show iscsi sessions (Figure 11-3) show iscsi sessions detailed [session isid] (Figure 11-4) show run iscsi Output Displays the currently configured iSCSI settings. Displays information on active iSCSI sessions on the switch. Displays detailed information on active iSCSI sessions on the switch. To display detailed information on specified iSCSi session, enter the session's iSCSi ID. Displays all globally-configured non-default iSCSI settings in the current FTOS session. Figure 11-2. show iscsi Command Example FTOS# show isci iSCSI is enabled iSCSI COS : dot1p is 4 no-remark Session aging time: 10 Maximum number of connections is 256 iSCSI Targets and TCP Ports TCP Port Target IP Address 3260 860 Figure 11-3. show iscsi sessions Command Example FTOS# show isci sessions Session 0 Target: iqn.2001-05.com.equallogic:0-8a0906-0e70c2002-10a0018426a48c94-iom010 Initiator: iqn.1991-05.com.microsoft:win-x9l8v27yajg ISID: 400001370000 Session 1 Target: iqn.2001-05.com.equallogic:0-8a0906-0f60c2002-0360018428d48c94-iom011 Initiator: iqn.1991-05.com.microsoft:win-x9l8v27yajg ISID: 400001370000. iSCSI Optimization | 153