Dell PowerEdge XL 5133-4 MXL 10/40GbE Switch IO Module FTOS Command Reference - Page 230
show redundancy Command Example, Indicates master unit, Failover type with redundancy
View all Dell PowerEdge XL 5133-4 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 230 highlights
www.dell.com | support.dell.com Figure 17-26. show redundancy Command Example FTOS#show redundancy -- Stack-unit Status -- Mgmt ID: 0 Stack-unit ID: 0 Stack-unit Redundancy Role: Primary Stack-unit State: Active Stack-unit SW Version: E8-3-17-46 Link to Peer: Up Indicates master unit -- PEER Stack-unit Status -- Stack-unit State: Standby Peer stack-unit ID: 1 Stack-unit SW Version: E8-3-17-46 Indicates standby unit -- Stack-unit Redundancy Configuration -- Primary Stack-unit: mgmt-id 0 Auto Data Sync: Full Failover Type: Hot Failover Auto reboot Stack-unit: Enabled Auto failover limit: 3 times in 60 minutes Failover type with redundancy -- Stack-unit Failover Record -- Failover Count: 0 Last failover timestamp: None Last failover Reason: None Last failover type: None -- Last Data Block Sync Record: -- Stack Unit Config: succeeded Sep 03 1993 09:36:52 Start-up Config: succeeded Sep 03 1993 09:36:52 Runtime Event Log: succeeded Sep 03 1993 09:36:52 Running Config: succeeded Sep 03 1993 09:36:52 ACL Mgr: succeeded Sep 03 1993 09:36:52 LACP: no block sync done STP: no block sync done SPAN: no block sync done Last synch of startup configuration 216 | Stacking