Dell PowerEdge XL 5133-4 MXL 10/40GbE Switch IO Module FTOS Command Reference - Page 222

Stacking Prerequisites, Cabling Stacked Switches, Cabling Restrictions, Cabling Redundancy

Page 222 highlights

www.dell.com | support.dell.com Stacking Prerequisites Before you cable and configure a stack of Aggregators, review the following prerequisites: • All Aggregators in the stack must be powered up with the initial or startup configuration before you attach the cables. • All stacked Aggregators must run the same FTOS version. The minimum FTOS version required is 8.3.17.0. To check the FTOS version that a switch is running, use the show version command. To download an FTOS version, go to http://support.dell.com. • Stacking is supported only with other Aggregators. A maximum of two Aggregators is supported in a single stack. You cannot stack the Aggregator with MXL 10/40GbE Switches or another type of switch. • A maximum of two stack groups (40GbE ports) is supported on a stacked Aggregator. • Interconnect the stack units by following the instructions in Cabling Stacked Switches. Cabling Stacked Switches Before you configure Aggregators in a stack, connect the 40G direct attach or QSFP cables and transceivers to connect 40GbE ports on two Aggregators in the same chassis. Cabling Restrictions The following restrictions apply when setting up a stack of Aggregators: • Only daisy-chain or ring topologies are supported; star and full mesh topologies are not supported. • Stacking is supported only on 40GbE links by connecting 40GbE ports on the base module. Stacking is not supported on 10GbE ports or 4x10GbE ports. • Use only QSFP transceivers and QSFP or direct attach cables (purchased separately) to connect stacking ports. Cabling Redundancy Connect the units in a stack with two or more stacking cables to avoid a stacking port or cable failure. Removing one of the stacked cables between two stacked units does not trigger a reset. 208 | Stacking

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290

208
|
Stacking
www.dell.com | support.dell.com
Stacking Prerequisites
Before you cable and configure a stack of Aggregators, review the following prerequisites:
All Aggregators in the stack must be powered up with the initial or startup configuration before you
attach the cables.
All stacked Aggregators must run the same FTOS version. The minimum FTOS version required is
8.3.17.0. To check the FTOS version that a switch is running, use the
show version
command. To
download an FTOS version, go to
.
Stacking is supported only with other Aggregators. A maximum of two Aggregators is supported in a
single stack. You cannot stack the Aggregator with MXL 10/40GbE Switches or another type of
switch.
A maximum of two stack groups (40GbE ports) is supported on a stacked Aggregator.
Interconnect the stack units by following the instructions in
Cabling Stacked Switches
.
Cabling Stacked Switches
Before you configure Aggregators in a stack, connect the 40G direct attach or QSFP cables and
transceivers to connect 40GbE ports on two Aggregators in the same chassis.
Cabling Restrictions
The following restrictions apply when setting up a stack of Aggregators:
Only daisy-chain or ring topologies are supported; star and full mesh topologies are not supported.
Stacking is supported only on 40GbE links by connecting 40GbE ports on the base module. Stacking is
not supported on 10GbE ports or 4x10GbE ports.
Use only QSFP transceivers and QSFP or direct attach cables (purchased separately) to connect
stacking ports.
Cabling Redundancy
Connect the units in a stack with two or more stacking cables to avoid a stacking port or cable failure.
Removing one of the stacked cables between two stacked units does not trigger a reset.