HP 6125G HP 6125G & 6125G/XG Blade Switches High Availability Command - Page 10

Parameters, Description, Examples, Display global Ethernet OAM configuration.

Page 10 highlights

Parameters |: Filters command output by specifying a regular expression. For more information about regular expressions, see Fundamentals Configuration Guide. begin: Displays the first line that matches the specified regular expression and all lines that follow. exclude: Displays all lines that do not match the specified regular expression. include: Displays all lines that match the specified regular expression. regular-expression: Specifies a regular expression, a case-sensitive string of 1 to 256 characters. Description Use display oam configuration to display global Ethernet OAM configuration, including the periods and thresholds for Ethernet OAM link error event detection. Related commands: oam errored-symbol period, oam errored-symbol threshold, oam errored-frame period, oam errored-frame threshold, oam errored-frame-period period, oam errored-frame-period threshold, oam errored-frame-seconds period, and oam errored-frame-seconds threshold. Examples # Display global Ethernet OAM configuration. display oam configuration Configuration of the link event window/threshold : Errored-symbol Event period(in seconds) : 1 Errored-symbol Event threshold : 1 Errored-frame Event period(in seconds) : 1 Errored-frame Event threshold : 1 Errored-frame-period Event period(in ms) : 1000 Errored-frame-period Event threshold : 1 Errored-frame-seconds Event period(in seconds) : 60 Errored-frame-seconds Event threshold : 1 Table 3 Command output Field Description Configuration of the link event window/threshold Detection intervals and triggering thresholds configured for link events. Errored-symbol Event period (in seconds) Errored symbol event detection interval, which defaults to one second. Errored-symbol Event threshold Errored symbol event triggering threshold, which defaults to 1. Errored-frame Event period (in seconds) Errored frame event detection interval, which defaults to one second. Errored-frame Event threshold Errored frame event triggering threshold, which defaults to 1. Errored-frame-period Event period Errored frame period event detection interval, which defaults to 1000 (in ms) milliseconds. Errored-frame-period Event threshold Errored frame period event triggering threshold, which defaults to 1. 5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159

5
Parameters
|
: Filters command output by specifying a regular expression. For more information about regular
expressions, see
Fundamentals Configuration Guide
.
begin
: Displays the first line that matches the specified regular expression and all lines that follow.
exclude
: Displays all lines that do not match the specified regular expression.
include
: Displays all lines that match the specified regular expression.
regular-expression
: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.
Description
Use
display oam configuration
to display global Ethernet OAM configuration, including the periods and
thresholds for Ethernet OAM link error event detection.
Related commands:
oam
errored-symbol period
,
oam
errored-symbol threshold
,
oam
errored-frame
period
,
oam
errored-frame threshold
,
oam
errored-frame-period period
,
oam
errored-frame-period
threshold
,
oam
errored-frame-seconds period
, and
oam
errored-frame-seconds threshold
.
Examples
# Display global Ethernet OAM configuration.
<Sysname> display oam configuration
Configuration of the link event window/threshold :
--------------------------------------------------------------------------
Errored-symbol Event period(in seconds)
:
1
Errored-symbol Event threshold
:
1
Errored-frame Event period(in seconds)
:
1
Errored-frame Event threshold
:
1
Errored-frame-period Event period(in ms)
:
1000
Errored-frame-period Event threshold
:
1
Errored-frame-seconds Event period(in seconds)
:
60
Errored-frame-seconds Event threshold
:
1
Table 3
Command output
Field
Description
Configuration of the link event
window/threshold
Detection intervals and triggering thresholds configured for link events.
Errored-symbol Event period (in
seconds)
Errored symbol event detection interval, which defaults to one second.
Errored-symbol Event threshold
Errored symbol event triggering threshold, which defaults to 1.
Errored-frame Event period (in
seconds)
Errored frame event detection interval, which defaults to one second.
Errored-frame Event threshold
Errored frame event triggering threshold, which defaults to 1.
Errored-frame-period Event period
(in ms)
Errored frame period event detection interval, which defaults to 1000
milliseconds.
Errored-frame-period Event
threshold