HP 6125G HP 6125G & 6125G/XG Blade Switches High Availability Command - Page 48

Description, Examples, Table 15, Command output

Page 48 highlights

exclude: Displays all lines that do not match the specified regular expression. include: Displays all lines that match the specified regular expression. regular-expression: Specifies a regular expression, a case-sensitive string of 1 to 256 characters. Description Use display cfd mp to display MP information. If no port is specified, this command displays the MP information on all ports. The output is arranged by port name, then in the ascending VLAN ID order on the same port, and in the order of outward-facing MEPs (from low to high level), MIPs, and inward-facing MEPs (from high to low level) within the same VLAN. Examples # Display the MP information on all ports. display cfd mp Interface GigabitEthernet1/0/1 VLAN 100 MEP ID: 100 Level: 0 Service instance: 100 Maintenance domain: mdtest0 Maintenance association: mainmd0 Direction: Outbound MEP ID: 105 Level: 5 Service instance: 105 Maintenance domain: mdtest5 Maintenance association: mainmd5 Direction: Outbound MIP Level: 6 Service instance: 106 Maintenance domain: mdtest6 Maintenance association: mainmd6 MEP ID: 104 Level: 4 Service instance: 104 Maintenance domain: mdtest4 Maintenance association: mainmd4 Direction: Inbound MEP ID: 102 Level: 2 Service instance: 102 Maintenance domain: mdtest2 Maintenance association: mainmd2 Direction: Inbound Interface GigabitEthernet1/0/4 VLAN 1 MEP ID: 9 Level: 6 Service instance: 6 Maintenance domain: mdtest6 Maintenance association: matest6 Table 15 Command output Direction: Outbound Field Interface GigabitEthernet1/0/1 VLAN 100 MEP ID MIP Description MP configuration of the specified VLAN on the specified port ID of the MEP A MIP in the MP 43

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159

43
exclude
: Displays all lines that do not match the specified regular expression.
include
: Displays all lines that match the specified regular expression.
regular-expression
: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.
Description
Use
display cfd mp
to display MP information.
If no port is specified, this command displays the MP information on all ports.
The output is arranged by port name, then in the ascending VLAN ID order on the same port, and in the
order of outward-facing MEPs (from low to high level), MIPs, and inward-facing MEPs (from high to low
level) within the same VLAN.
Examples
# Display the MP information on all ports.
<Sysname> display cfd mp
Interface GigabitEthernet1/0/1
VLAN 100
MEP ID: 100
Level: 0
Service instance: 100
Direction: Outbound
Maintenance domain: mdtest0
Maintenance association: mainmd0
MEP ID: 105
Level: 5
Service instance: 105
Direction: Outbound
Maintenance domain: mdtest5
Maintenance association: mainmd5
MIP
Level: 6
Service instance: 106
Maintenance domain: mdtest6
Maintenance association: mainmd6
MEP ID: 104
Level: 4
Service instance: 104
Direction: Inbound
Maintenance domain: mdtest4
Maintenance association: mainmd4
MEP ID: 102
Level: 2
Service instance: 102
Direction: Inbound
Maintenance domain: mdtest2
Maintenance association: mainmd2
Interface GigabitEthernet1/0/4
VLAN 1
MEP ID: 9
Level: 6
Service instance: 6
Direction: Outbound
Maintenance domain: mdtest6
Maintenance association: matest6
Table 15
Command output
Field
Description
Interface GigabitEthernet1/0/1
VLAN 100
MP configuration of the specified VLAN on the specified
port
MEP ID
ID of the MEP
MIP
A MIP in the MP