HP t310 PCoIP Management Console User Manual - Page 57
Apply Profile
View all HP t310 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 57 highlights
PCoIP Management Console User Manual 4.3.1.5 The following is a description of each status category: • Successful: The profile was successfully written to the device. • Scheduled: The MC has scheduled the profile to be written to the device. • Failed: The MC attempted but failed to write the profile to the device. This problem typically occurs when devices are offline. • Unapplied: The profile was modified since it was last written to the device. This lets you know when you need to reapply a profile to one or more devices in a group. Apply a Profile to a Group Click the Apply Profile link to write the device profile settings to every device in a group. Profiles can contain properties that require a device reboot when the profile is applied. The Apply Profile confirmation dialog displays radio buttons to select automatic or manual device rebooting. Figure 4-15 shows the reboot behavior choices. The default behavior is to automatically reboot the device. Profiles can be scheduled to be applied in the future. Click in the Apply Profile at Date/Time field to display a graphical date/time picker. Figure 4-16 shows the date/time picker. To determine when the profile was written to devices in the group, watch the Group Management webpage until the number of Scheduled updates is 0. At this point, the MC has completed all attempts to write the profile to the devices in the group. If a device was offline when the MC tried to write the profile the status is marked as Failed. To see the View Profile Application status with the filter set to this group, click View Details. Figure 4-15: Apply Profile Reboot Behavior Options TER0812002 Issue 9 58