IBM 436854u Service Guide - Page 166
Power problems, See Power-supply LEDs
UPC - 883436026772
View all IBM 436854u manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 166 highlights
Power problems v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, "Parts listing, System x3200 M2 Types 4367 and 4368," on page 33 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service technician. Symptom Action The power-control button does 1. Make sure that the front-panel assembly power-control button is working not work (the server does not correctly: start). Note: The power-control button a. Disconnect the server power cords. will not function until 20 b. Reconnect the power cords. seconds after the server has c. Press the power-control button. been connected to ac power. 2. Make sure that: v The power cords are correctly connected to the server and to a working electrical outlet. v The server contains the correct type of DIMMs. v The DIMMs are correctly seated. v The LEDs on the power supply do not indicate a problem. v The microprocessor is correctly installed. 3. Reseat the following components: a. DIMMs b. Power supply cables to all internal components c. Power supplies (hot-swap models) 4. Replace the following components one at a time, in the order shown, restarting the server each time: a. DIMMs b. Power supplies (hot-swap models) c. (Trained service technician only) Power supply (non-hot swap models) 5. If you just installed an optional device, remove it, and restart the server. If the server now starts, you might have installed more devices than the power supply supports. 6. See "Power-supply LEDs" on page 153. 7. See "Solving undetermined problems" on page 229. The server does not turn off. 1. Determine whether you are using an Advanced Configuration and Power Interface (ACPI) or a non-ACPI operating system. If you are using a non-ACPI operating system, complete the following steps: a. Press Ctrl+Alt+Delete. b. Turn off the server by holding the power-control button for 5 seconds. c. Restart the server. d. If the server fails POST and the power-control button does not work, disconnect the ac power cord for 20 seconds; then, reconnect the ac power cord and restart the server. 2. (Trained service technician only) If the problem remains or if you are using an ACPI-aware operating system, suspect the system board. The server unexpectedly shuts See "Solving undetermined problems" on page 229. down, and the LEDs on the front-panel assembly are not lit. 148 System x3200 M2 Types 4367 and 4368: Problem Determination and Service Guide