IBM 436854u Service Guide - Page 243
Trained service technician only Reseat the microprocessor.
UPC - 883436026772
View all IBM 436854u manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 243 highlights
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, "Parts listing, System x3200 M2 Types 4367 and 4368," on page 33 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained service technician. System-error log message Action System shutoff due to board over temperature 1. Make sure that all fans have good airflow and are not obstructed. 2. (Trained service technician only) Replace the system board. System shutoff due to continuous +5V over voltage 1. Reseat the following components: a. Hot-swap power supplies, if any are installed b. Power supply cables on the system board 2. (Trained service technician only) Replace the system board. System shutoff due to continuous +5V under voltage 1. Reseat the following components: a. Hot-swap power supplies, if any are installed b. Power supply cables on the system board 2. (Trained service technician only) Replace the system board. System shutoff due to CPU over temperature 1. Make sure that the fan sink has good airflow and is not obstructed. 2. Reseat the following components: a. Fan sink cable b. (Trained service technician only) Fan sink System shutoff due to VRM over voltage 1. (Trained service technician only) Reseat the microprocessor. 2. Replace the following components one at a time, in the order shown, restarting the server each time: a. (Trained service technician only) Microprocessor b. (Trained service technician only) System board System shutoff due to VRM under voltage 1. (Trained service technician only) Reseat the microprocessor. 2. Replace the following components one at a time, in the order shown, restarting the server each time: a. (Trained service technician only) Microprocessor b. (Trained service technician only) System board System under recommended voltage for +12V 1. Reseat the following components: a. Hot-swap power supplies, if any are installed b. Power supply cables on the system board 2. (Trained service technician only) Replace the system board. System under recommended voltage on +2.5V 1. Reseat the following components: a. Hot-swap power supplies, if any are installed b. Power supply cables on the system board 2. (Trained service technician only) Replace the system board. System under recommended voltage on continuous +5V 1. Reseat the following components: a. Hot-swap power supplies, if any are installed b. Power supply cables on the system board 2. (Trained service technician only) Replace the system board. Chapter 5. Diagnostics 225