Sony PMW200 User Manual (PMW-100 Memory Camcorder Operation Manual for Firmwar - Page 98

Tally, Hours Meter, IR Remote, Battery Alarm, Battery INFO, Genlock, Direct Menu, Trigger Mode

Page 98 highlights

OTHERS Menu items Subitems and setting values Contents Steady Shot: For turning the Steady Shot function on/off. Tally Setting the tally lamps Front High / Low / Off Set the brightness of the tally lamp. High: To brighten the lamp Low: To dim the lamp Off: To not light the lamp Hours Meter Displaying the hours meter Hours (Sys) Hours (Reset) Reset Execute/Cancel The non-resettable accumulated time of use is displayed. The resettable accumulated time of use is displayed. Select "Execute" to reset the Hours (Reset) value to 0. IR Remote Activating/ deactivating the Remote Commander On / Off Set to "On" to activate remote control operations from the supplied IR Remote Commander. Note The setting automatically returns to "Off" when the camcorder is turned off. Battery Alarm Low BATT Setting the low 5% / 10% / 15% / ... / 45% / power alarm 50% Set the battery level at which the Low BATT warning is generated (in steps of 5%). BATT Empty 3% to 7% (3%) Set the battery level at which the BATT Empty warning is generated. DC Low Volt1 11.5 V to 17.0 V (11.5 V) Set the DC IN voltage at which the DC Low Volt1 warning is generated. DC Low Volt2 11.0 V to 14.0 V (11.0 V) Set the DC IN voltage at which the DC Low Volt2 warning is generated. Battery INFO Showing information regarding the battery pack (display only) Type MFG Date Charge Count Capacity Voltage The type (product name) is displayed. The date of manufacture is displayed. The accumulated number of times of charge/discharge is displayed. The estimated total capacity of full charge is displayed. The current output voltage is displayed. Remaining The current remaining level is displayed. Genlock Setting Genlock operation H Phase (HD) -999 to +999 (±0) H Phase (SD) -99 to +99 (±0) Set the H phase (phase of the horizontal sync signal) of HD signal for Genlock operation. Set the H phase (phase of the horizontal sync signal) of SD signal for Genlock operation. Direct Menu Setting the Direct menu function All / Part / Off All: All Direct menu operations are permitted. Part: A part of Direct menu operations is permitted. The operation is limited depending on the GAIN, SHUTTER, or WHITE BAL switch setting. Off: No Direct menu operation is permitted. Trigger Mode Setting for operating an external recording device connected via the i.LINK connector (FAT only) [M] Internal / Both / External Internal: To activate recording start/stop operations only for an SxS memory card in a built-in slot. Both: To activate recording start/stop operations both for an SxS memory card in a built-in slot and the external recording device connected via the i.LINK connector. External: To activate recording start/stop operations only for the external recording device connected via the i.LINK connector. Menu Configuration and Detailed Settings 98 Setup Menu List

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142

Setup Menu List
98
Menu Configuration and Detailed Settings
Steady Shot: For turning the Steady Shot function on/off.
Tally
Setting the tally
lamps
Front
High
/ Low / Off
Set the brightness of the tally lamp.
High: To brighten the lamp
Low: To dim the lamp
Off: To not light the lamp
Hours Meter
Displaying the
hours meter
Hours (Sys)
The non-resettable accumulated time of use is displayed.
Hours (Reset)
The resettable accumulated time of use is displayed.
Reset
Execute/Cancel
Select “Execute” to reset the Hours (Reset) value to 0.
IR Remote
Activating/
deactivating the
Remote
Commander
On /
Off
Set to “On” to activate remote control operations from the
supplied IR Remote Commander.
Note
The setting automatically returns to “Off” when the
camcorder is turned off.
Battery Alarm
Setting the low
power alarm
Low BATT
5% /
10%
/ 15% / ... / 45% /
50%
Set the battery level at which the Low BATT warning is
generated (in steps of 5%).
BATT Empty
3% to 7% (
3%
)
Set the battery level at which the BATT Empty warning is
generated.
DC Low Volt1
11.5 V to 17.0 V (
11.5 V
)
Set the DC IN voltage at which the DC Low Volt1 warning is
generated.
DC Low Volt2
11.0 V to 14.0 V (
11.0 V
)
Set the DC IN voltage at which the DC Low Volt2 warning is
generated.
Battery INFO
Showing
information
regarding the
battery pack
(display only)
Type
The type (product name) is displayed.
MFG Date
The date of manufacture is displayed.
Charge Count
The accumulated number of times of charge/discharge is
displayed.
Capacity
The estimated total capacity of full charge is displayed.
Voltage
The current output voltage is displayed.
Remaining
The current remaining level is displayed.
Genlock
Setting Genlock
operation
H Phase (HD)
–999 to +999 (±
0
)
Set the H phase (phase of the horizontal sync signal) of HD
signal for Genlock operation.
H Phase (SD)
–99 to +99 (±
0
)
Set the H phase (phase of the horizontal sync signal) of SD
signal for Genlock operation.
Direct Menu
Setting the Direct
menu function
All /
Part
/ Off
All: All Direct menu operations are permitted.
Part: A part of Direct menu operations is permitted.
The
operation is limited depending on the GAIN, SHUTTER,
or WHITE BAL switch setting.
Off: No Direct menu operation is permitted.
Trigger Mode
Setting for
operating an
external recording
device connected
via the i.LINK
connector (FAT
only)
[M]
Internal /
Both
/ External
Internal: To activate recording start/stop operations only for
an SxS memory card in a built-in slot.
Both: To activate recording start/stop operations both for an
SxS memory card in a built-in slot and the external
recording device connected via the i.LINK connector.
External: To activate recording start/stop operations only for
the external recording device connected via the i.LINK
connector.
OTHERS
Menu items
Subitems and setting values
Contents