D-Link DNS-1250-04 User Manual for DNS-1250-04 - Page 50
Locating a Logical Drive, Logical Drive, Check Table, Storage
View all D-Link DNS-1250-04 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 50 highlights
2. Click the Logical Drive button. 3. Mouse-over the logical drive you want and click the Check Table button. 4. Choose an option. All - All errors. The default choice. Read Check - Read errors for this logical drive. Write Check - Write errors for this logical drive. Inconsistent Block - Inconsistent blocks for this logical drive. Mirror data for RAID Levels 1, 1E and 10. Parity data for RAID Levels 5, 6, and 50. Errors and inconsistent blocks are identified by Redundancy Check. Each Check Table lists: Entry Number - A number assigned to each block of entry. Table Type - Read Check, Write Check or Inconsistent Block. Starting Logical Block Address - LBA of the first block for this entry. Count - Number of errors or continuous blocks starting from this LBA. Locating a Logical Drive To locate a logical drive: 1. Click the Storage tab. 2. Click the Logical Drive button. 42