Dell PowerEdge R830 Owners Manual - Page 109

Installing the integrated storage controller card

Page 109 highlights

Figure 43. Installing the integrated storage controller card 1. integrated storage controller card 3. riser 3 2. expansion card latch 4. SAS cable 5. Connect the SAS data cables to the SAS data cable connectors on the integrated storage controller card. NOTE: Ensure that you connect the cable according to the connector labels on the cable. The cable does not function properly if reversed. 6. Connect the SAS data cable to the system board. Next steps 1. Install the expansion card riser 1. 2. If applicable, install the cooling shroud. 3. Follow the procedure listed in the After working inside your system section. Related references Safety instructions on page 63 Related tasks Before working inside your system on page 64 Removing the cooling shroud on page 76 Installing the cooling shroud on page 77 Installing an expansion card into expansion card riser 1 on page 120 After working inside your system on page 64 Installing and removing system components 109

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189

Figure 43. Installing the integrated storage controller card
1.
integrated storage controller card
2.
expansion card latch
3.
riser 3
4.
SAS cable
5.
Connect the SAS data cables to the SAS data cable connectors on the integrated storage controller card.
NOTE:
Ensure that you connect the cable according to the connector labels on the cable. The cable does not function
properly if reversed.
6.
Connect the SAS data cable to the system board.
Next steps
1.
Install the expansion card riser 1.
2.
If applicable, install the cooling shroud.
3.
Follow the procedure listed in the After working inside your system section.
Related references
Safety instructions
on page 63
Related tasks
Before working inside your system
on page 64
Removing the cooling shroud
on page 76
Installing the cooling shroud
on page 77
Installing an expansion card into expansion card riser 1
on page 120
After working inside your system
on page 64
Installing and removing system components
109