Epson 9600 Service Manual - Page 142
CR servo parameter error 0001001D, 2.4.19, PF servo parameter error 0001001E
UPC - 010343841888
View all Epson 9600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 142 highlights
EPSON Stylus Pro 7600/9600 Revision A 3.2.4.18 CR servo parameter error (0001001D) Explanation: There may be a case where a voltage exceeding the specified value is about to be applied to the CR Motor. In such a case, this message is displayed and the printer stops operating. Cause of trouble: • A small PWM output is kept on for a certain period of time (load is kept applied). • Carriage related mechanism out of step or carriage bumped. Points to be checked: 1. The CR Encoder and the T Fence must be free from dust and dirt or any other foreign matters. 2. The CR Timing Belt must be free from any defects and the belt must be in proper tension. 3. The carriage must slide smoothly, free from undue load. 4. Measure the resistance value of the CR Motor.(5.8Ω) If the CR Motor is found in short mode, replace the C472MAIN Board at the same time. 5. Execute encoder checking by "5.2.2.4 Encoder "(p225) in the selfdiagnostics menu. 6. All the harness must be connected properly and free from short circuit or broken wire. Remedy: • Replace the MAIN Board (C472 MAIN) (p.207). • Replace the CR Encoder Sensor ASSY (p.178). (Refer to "CR Encoder Sensor Mounting Position Adjustment" (p.268)) • Replace the CR Motor ASSY (p.180). (Refer to "CR Timing Belt Tension Adjustment" (p.263)) • Make the mechanism adjustment for the carriage-related mechanism. • Remove the foreign matters. 3.2.4.19 PF servo parameter error (0001001E) Explanation: There may be a case where a voltage exceeding the specified value is about to be applied to the PF Motor. In such a case, this message is displayed and the printer stops operating. Cause of trouble: • A small PWM output is kept on for a certain period of time (load is kept applied). • Paper feed related mechanism out of step. Points to be checked: 1. The PF Encoder and the PF Loop Scale must be free from dust and dirt or any other foreign matters. 2. The PF Timing Belt must be free from any defects and the belt must be in proper tension. 3. The grid roller must rotate smoothly, free from undue load. 4. Measure the resistance value of the CR Motor.(5.8Ω) If the CR Motor is found in short mode, replace the C472MAIN Board at the same time. 5. Execute encoder checking by "5.2.2.4 Encoder "(p225) in the selfdiagnostics menu. 6. All the harness must be connected properly and free from short circuit or broken wire. Remedy: • Replace the MAIN Board (C472 MAIN) (p.207). • Replace the PF Encoder Sensor ASSY (p.186). (Refer to PF Encoder Sensor Installation Position Adjustment (p.272)) • Replace the PF Motor (p.185). (Refer to PF Timing Belt Tension Adjustment (p.264)) • Clear the cause of paper feed related mechanism out-of-step. Troubleshooting Error Display 142