Epson 9600 Service Manual - Page 179
P_EGDE Sensor ASSY
UPC - 010343841888
View all Epson 9600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 179 highlights
EPSON Stylus Pro 7600/9600 4.3.6 P_EGDE Sensor ASSY 1. Remove the R Side Cover. (p.160) 2. Remove the L Side Cover. (p.163) 3. Remove the I/H Cover. (p.164) 4. Remove the H Top Cover. (p.165) 5. Remove one screw (CPP M3×6), two screws (CP(W): M3×6) and one screw (M3×16) securing the CR Board Guide, and also the ground line and the toothed washer (M3), and remove the CR Board Guide. (See Figure 4-30) 6. Disconnect the connector (4-pin, black) for the P_EDGE Sensor from the CR Board. C A U T IO N If you can not disconnect easily the connector for the P_EDGE Sensor, do not disconnect it by undue force. Disconnect the two FFCs for the print head first and then the connector for the P_EDGE Sensor. 7. Remove the two screws securing the CR Board Unit in the Carriage Unit, and take out the CR Board Unit toward the front. (See Figure 4-39) 8. Remove the one screw (M3×6) securing the EDGE Sensor Base ASSY and remove the EDGE Sensor Base ASSY. (See Figure 4-40) After installing the P_EDGE Sensor ASSY on the Cutter Holder ASSY, fasten the harness to the harness holding path of the Cutter Holder ASSY. (See Figure 4-40) A D JU S TM E N T R E Q U IR E D After replacing the P_EDGE Sensor, the following adjustment operation should be performed. "P_EDGE Sensor ASSY Adjustment (p.215)" Revision A Screws ×2 Connector CR Board Unit Figure 4-39. Removing the P_EDGE Sensor ASSY 1/2 Lead the lead wires in this groove. P_EDGE Sensor Base Disassembly & Assembly Figure 4-40. Removing the P_EDGE Sensor ASSY 2/2 Disassembly and Assembly of Carriage (CR) Mechanism 179