Epson 9600 Service Manual - Page 180
CR Motor ASSY
UPC - 010343841888
View all Epson 9600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 180 highlights
EPSON Stylus Pro 7600/9600 4.3.7 CR Motor ASSY This section describes the replacement procedure for the following parts of the CR Motor ASSY. CR Timing Belt Driven Pulley (Stylus Pro 7600: white / Stylus Pro 9600: black) Before installing the covers, adjust the indicator position (the right end of the projection on the CR tension spring support) of the CR tension bracket to the center by turning the CR Tension Mounting Shaft. However, if the indicator was at a off-center position before assembly, adjust the indicator to the same off-center position. (See Figure 4-42) 1. Remove the R Side Cover. (p.160) 2. Remove the L Side Cover. (p.163) 3. Remove the I/H Cover. (p.164) 4. Remove the H Top Cover. (p.165) 5. Release the carriage lock and move the carriage from the capping position. (See Figure 4-24) 6. On the R Side Frame side, remove the CR Tension Mounting Shaft and CR Tension Spring and the CR Tension Spring Support. (See Figure 4-42) 7. Slide the CR Tension Bracket to the left (toward the CR Motor), and remove the CR Timing Belt, together with the Driven Pulley, from the CR Tension Bracket. Revision A Projection (CR tension spring support) Adjust the right end to the center Figure 4-41. Indicator Position Driven Pulley CR Tension Spring Support Timing Belt CR Tension Spring Remove the CR Tension Mounting Shaft Record scale reading CR Tension Bracket Disassembly & Assembly Figure 4-42. Loosening the CR Timing Belt Disassembly and Assembly of Carriage (CR) Mechanism 180