Epson 9600 Service Manual - Page 253

Head Gap Adjustment Uni-D Adjustment

Page 253 highlights

EPSON Stylus Pro 7600/9600 5.2.3.18 Head Gap Adjustment (Uni-D Adjustment) Correct the print position for one-way printing. Make adjustments of "240CPS VSD1", "240CPS VSD2" and "190CPS VSD4" for each color. Store the adjustment values for each line of nozzles (18 kinds of values) in the Flash ROM. For adjustment, conduct Uni-D printing and from the print results, input the compensation value. The menu transition for Uni-D adjustment and print patterns are shown below. Table 5-23. Head Gap Adjustment Items Item Contents Gap 240,V1 Uni-D Adjustment 240CPS VSD1 Gap 240,V2 Uni-D Adjustment 240CPS VSD2 Gap 190,V4 Uni-D Adjustment 190CPS VSD4 „ Adjustment resolution: 8.8 µm „ Adjustable range: ± 62 step adjustment possible „ Pattern drawing method: 360dpi, Uni-D, 240CPS, VSD1, Large (240V1 selected) 360dpi, Uni-D, 240CPS, VSD2, Large (240V2 selected) 360dpi, Uni-D, 190CPS, VSD4, Large (190V4 selected) „ Press the [Enter] key after inputting the adjusted values and pattern number, and the pattern will be printed only when updated values have been input. When the values have not been updated, the display will change to the next input screen. „ When the [Enter] key is pressed with "Gap End" displayed, the display changes to "Adj: Feed Adj.+T&B". CHECK P O IN T The adjustment is not required for any of #1, #8 and #15, which are black lines. Revision A [Enter] Adjust Print [Enter] Printing Pattern Printing end Gap 240, V1 ? ? Gap 240, V2 ? ? Gap 190, V4 ? ? Gap End ? ? [Pause] 240V1 LK : ? [SelecType] 240V1 C : ? [SelecType] 240V1 LC : ? [SelecType] 240V1 M : ? [SelecType] 240V1 LM : ? [SelecType] 240V1 Y : ? [SelecType] Value with +/- can be set in pulses 0 1 pulse is equivalent to 1/2880" Value with +/- can be set in pulses 0 1 pulse is equivalent to 1/2880" Value with +/- can be set in pulses 0 1 pulse is equivalent to 1/2880" Value with +/- can be set in pulses 0 1 pulse is equivalent to 1/2880" Value with +/- can be set in pulses 0 1 pulse is equivalent to 1/2880" Value with +/- can be set in pulses 0 1 pulse is equivalent to 1/2880" Figure 5-54. Menu Transition for Uni-D Adjustment Adjustment Self-diagnostic Function 253

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297
  • 298
  • 299
  • 300
  • 301
  • 302
  • 303
  • 304
  • 305
  • 306
  • 307
  • 308
  • 309
  • 310
  • 311
  • 312
  • 313
  • 314
  • 315
  • 316
  • 317
  • 318
  • 319
  • 320
  • 321
  • 322
  • 323
  • 324
  • 325
  • 326
  • 327
  • 328
  • 329
  • 330
  • 331
  • 332
  • 333
  • 334
  • 335
  • 336

EPSON Stylus Pro 7600/9600
Revision A
Adjustment
Self-diagnostic Function
253
5.2.3.18
Head Gap Adjustment (Uni-D Adjustment)
Correct the print position for one-way printing.
Make adjustments of “240CPS VSD1”, “240CPS VSD2” and “190CPS VSD4” for
each color.
Store the adjustment values for each line of nozzles (18 kinds of values) in the Flash
ROM.
For adjustment, conduct Uni-D printing and from the print results, input the
compensation value.
The menu transition for Uni-D adjustment and print patterns are shown below.
Adjustment resolution: 8.8
µ
m
Adjustable range:
±
62 step adjustment possible
Pattern drawing method:
360dpi, Uni-D, 240CPS, VSD1, Large (240V1 selected)
360dpi, Uni-D, 240CPS, VSD2, Large (240V2 selected)
360dpi, Uni-D, 190CPS, VSD4, Large (190V4 selected)
Press the [Enter] key after inputting the adjusted values and pattern number,
and the pattern will be printed only when updated values have been input.
When the values have not been updated, the display will change to the next
input screen.
When the [Enter] key is pressed with “Gap End” displayed, the display
changes to “Adj: Feed Adj.+T&B”.
Figure 5-54.
Menu Transition for Uni-D Adjustment
Table 5-23.
Head Gap Adjustment Items
Item
Contents
Gap 240,V1
Uni-D Adjustment 240CPS VSD1
Gap 240,V2
Uni-D Adjustment 240CPS VSD2
Gap 190,V4
Uni-D Adjustment 190CPS VSD4
C
H
E
C
K
P
O
I
N
T
The adjustment is not required for any of #1, #8 and #15, which are
black lines.
Gap
240, V1
?
?
Gap
240, V2
?
?
Gap
190, V4
?
?
Gap End
?
?
240V1
Y :
?
0
Value with +/- can be set in pulses
1 pulse is equivalent to 1/2880”
240V1
LK :
?
0
240V1
C :
?
0
240V1
LC :
?
0
240V1
M :
?
0
240V1
LM :
?
0
[Enter]
[SelecType]
[SelecType]
[SelecType]
[SelecType]
[SelecType]
[Enter] Adjust Print
Printing Pattern
Printing end
[Pause]
[SelecType]
Value with +/- can be set in pulses
1 pulse is equivalent to 1/2880”
Value with +/- can be set in pulses
1 pulse is equivalent to 1/2880”
Value with +/- can be set in pulses
1 pulse is equivalent to 1/2880”
Value with +/- can be set in pulses
1 pulse is equivalent to 1/2880”
Value with +/- can be set in pulses
1 pulse is equivalent to 1/2880”