HP Workstation x1000 hp workstations general - adaptec RAID installation guide - Page 109
Especifications
View all HP Workstation x1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 109 highlights
E specifications DC Power Requirements Voltage Ripple and noise 5 V 5% 50 mV peak-to-peak maximum Current Requirements Adaptec 2400A/2100S Adaptec 3200S/3210S/3410S Adaptec 200S bus expansion module Battery backup module Nominal Charging Memory module 1.5 A 2.0 A 1.7 A 0.27 A 1.16 A 0.1 A Environmental Specifications Ambient temperature without battery backup module 0 ˚C to 50 ˚ C Ambient temperature with battery backup 0 ˚C to 40 ˚ C module-Adaptec 3200S/3210S/3400S/3410S only Relative humidity 10% to 90%, noncondensing Altitude up to 3,000 meters Note: Forced airflow is recommended, but not required. E-1
E-1
E
specifications
DC Power Requirements
Current Requirements
Environmental Specifications
Note:
Forced airflow is recommended, but not required.
Voltage
5 V
5%
Ripple and noise
50 mV peak-to-peak maximum
Adaptec 2400A/2100S
1.5 A
Adaptec 3200S/3210S/3410S
2.0 A
Adaptec 200S bus expansion module
1.7 A
Battery backup module
Nominal
Charging
0.27 A
1.16 A
Memory module
0.1 A
Ambient temperature without battery
backup module
0 ˚C to 50 ˚C
Ambient temperature with battery backup
module—
Adaptec 3200S/3210S/3400S/3410S only
0 ˚C to 40 ˚C
Relative humidity
10% to 90%
,
noncondensing
Altitude
up to 3,000 meters