IBM 8669 Hardware Maintenance Manual - Page 106
Remote Supervisor Adapter, if installed
UPC - 087944636496
View all IBM 8669 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 106 highlights
Error Code/Symptom FRU/Action 1600 (The System Management Processor is not functioning) Do the following before replacing a FRU: 1. Ensure that a jumper is not installed on J45. 2. Remove the ac power to the system, wait 20 seconds; then, re-connect the ac power. Wait 30 seconds; then, power-on the system. 1. System Board 1601 (The system is able to communicate 1. Remote Supervisor Adapter, if installed to the System Management Processor, but the System Management Processor failed 2. System Board to respond at the start of POST.) Do the following before replacing a FRU: 1. Remove the ac power to the system, wait 20 seconds; then, re-connect the ac power. Wait 30 seconds; then, power-on the system. 2. Flash update the Service Processor. 1762 (Fixed Disk Configuration error) 1. Fixed Disk Drive 2. Fixed Disk Cables 3. Run Configuration/Setup 4. Fixed Disk Adapter 5. SCSI Backplane 6. System Board 178X (Fixed Disk error) 1. Fixed Disk Cables 2. Run Diagnostics 3. Fixed Disk Adapter 4. Fixed Disk Drive 5. System Board 1800 (No more hardware interrupt available for PCI adapter) 1. Run Configuration/Setup 2. Failing Adapter 3. System Board 1962 (Drive does not contain a valid boot sector) 1. Verify a bootable operating system is installed. 2. Run Diagnostics 3. Hard Disk Drive 4. SCSI Backplane 5. Cable 6. System Board 2400 (Video controller test failure) 1. Video Adapter (if installed) 2. System Board 2462 (Video memory configuration error) 1. Video Adapter (if installed) 2. System Board 96 Hardware Maintenance Manual: xSeries 342 Type 8669