Miele DGC 7585 Operating and Installation instructions - Page 186
Drainage, Attaching the plastic hose to the steam oven, Connecting the water drainage system
View all Miele DGC 7585 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 186 highlights
*INSTALLATION* Installation Drainage The drainage trap must not be located higher than the drain-hose connection point on the steam oven. This is to ensure that water can drain out completely. The top end of the plastic hose must not be higher than 19 11/16" (500 mm) where it connects to the trap. The plastic hose supplied is 9' 10 1/8" (3.0 m) long. We recommend only using the original hose from Miele. The plastic hose supplied must not be shortened. Attaching the plastic hose to the steam oven Make sure that the plastic hose is not kinked or damaged. Plug the plastic hose onto the waste water connection on the steam oven. Then secure the plastic hose with the hose clip. Connecting the water drainage system Connect the plastic hose to the trap using the hose sleeve. Then secure the plastic hose with the hose clip. The drain hose can be connected to: - a surface-mounted or flush-mounted trap with a fixed hose connection, or - the connection point on a sink drainage trap The temperature of the drainage water is 160°F (70°C). 186