Tripp Lite 0SU70032 Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207
Tripp Lite 0SU70032 Manual
![]() |
View all Tripp Lite 0SU70032 manuals
Add to My Manuals
Save this manual to your list of manuals |
Tripp Lite 0SU70032 manual content summary:
- Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 1
Smart 108/116 IP User Guide 1111 W. 35th Street, Chicago, IL 60609 USA www.tripplite.com/support Copyright ©2012 Tripp Lite. All rights reserved. - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 2
only in accordance with the terms of such license. The content of this manual is provided for informational use only, and is subject to change without should not in and of itself be construed as a commitment by Minicom Advanced Systems Limited, which assumes no responsibility of liability for any - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 3
provide feedback on the user guide, and WEEE Information for Minicom Customers and Recyclers. Pg. and security settings. It also provides instructions for installing an SSL certificate, System Locally firmware, and how to troubleshoot problems that occur when updating the software. 7 - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 4
. Special terms, the first time they appear. Text entered by the user. Notes, which offer an additional explanation or a hint on how to overcome a common problem. Warnings, which indicate potentially damaging user operations and explain how to avoid them. iv | Smart 108/116 IP - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 5
/ROC USB 20 2.6.3 Connecting a RICC SUN 20 2.7 CONNECTING TO THE NETWORK 21 2.8 CONNECTING THE CAT5 CABLES 21 2.9 CONNECTING THE KVM CONSOLE 21 2.10 CONNECTING THE POWER SUPPLY 22 3 CONFIGURING THE NETWORK 23 3.1 BOOT-UP PROCESS 23 Assigning Static IP Addresses for a Number of Units 24 User - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 6
PERFORMANCE SETTINGS 45 4.7 ADJUSTING THE VIDEO 47 4.7.1 Refreshing the Video Image 47 4.7.2 Automatically Adjusting the Video Image 47 4.7.3 Manually Adjusting Video Settings 47 4.8 MANAGING KEYBOARD SEQUENCES 49 4.8.1 Adding a Keyboard Sequence 49 4.8.2 Recording a New Custom Key 51 vi - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 7
Manually Synchronizing the Mouse 53 The USB Option...54 Advanced Mouse Emulation 55 4.9.2 Aligning the Mouse Pointers 55 4.9.3 Calibrating Mouse Pointers 56 4.10 SWITCHING TO A DIFFERENT SERVER 56 4.11 DISCONNECTING THE REMOTE SESSION 56 5 TROUBLESHOOTING /116 IP FIRMWARE 72 User Guide | vii - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 8
76 RICC/ROC Version ...77 6.3.8 Obtaining New Firmware 77 Updating the Firmware 77 Manually Updating the RICC/ROCs 78 6.3.9 Restoring Factory Settings 79 6.4 TROUBLESHOOTING - UPDATE SOFTWARE 79 6.4.1 Communication Error Message 79 6.4.2 Electricity Failure 79 7 TECHNICAL SPECIFICATIONS 81 - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 9
Box 44 Figure 34 - Remote Presence Solutions Information 45 Figure 35 - Performance Settings 46 Figure 36 - Video Adjust Progress 47 Figure 37 - Manual Video Adjustments Controls 48 Figure 38 - Special Key Manager 50 Figure 39 - Add a Predefined Key Dialog Box 50 Figure 40 - Record Macro - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 10
Table of Figures Figure 41 - Delete Key(s) Confirmation Box 52 Figure 42 - Relative Mouse Settings 53 Figure 43 - Windows 7 Mouse Properties 54 Figure 44 - Mouse Emulation Box 55 Figure 45 - Safe Mode Procedure 57 Figure 46 - Login Page 58 Figure 47 - Safe Mode Menu 58 Figure 48 - Warning 59 - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 11
instructions for Minicom 's Smart 108/116 IP. It is intended for system administrators and network managers, and assumes that readers have a general understanding of networks, hardware, and software. Chapter 3 and Chapter 4 of this guide star configuration. No external power is needed at the - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 12
or later version Linux with Firefox 3; 128-bit encryption support is required 1.5 Technical Precautions This equipment generates radio frequency energy, and if not installed in accordance with the manufacturer's instructions, may cause radio frequency interference. This equipment complies with - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 13
Minicom Advanced Systems Limited, will be responsible. Changes or modifications made to this equipment not expressly approved by Minicom Minicom technician. Disconnect the device from the power source and all cables from the device before service equipment from Minicom, they waste Instructions for both - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 14
in good working condition. 2. Mount the Smart 108/116 IP unit in a rack. 3. Make all hardware connections between the power source, Smart 108/116 IP, services, network, and KVM console. 4. Power on the Smart 108/116 IP unit. 2.2 System Components Before installing the Smart 108/116 IP system, verify - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 15
the state of the Smart 108/116 IP unit: Green indicates that the unit is powered on; Red indicates that the unit is powered off. Illuminates to indicate that a remote session is active. Illuminates to indicate that 10 Mbit/sec network. For connecting to the servers via the RICC/ROCs. User Guide | 15 - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 16
air conditioners, and not intended for connection to exposed outdoor lines. Ensure that the maximum distance between supply circuit, make sure that the total power of all the components does not exceed the circuit capabilities. Overloading of circuits can affect over-current protection and supply - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 17
3. Install the Smart 108/116 IP nit into the server rack by connecting the bracket to the rack with screws, according to the rack manufacturer's instructions. 2.5 Connecting the System Figure 5 illustrates the Smart 108/116 IP system overview. User - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 18
the Smart 108/116 IP via an appropriate ROC or RICC using a CAT5 cable in star configuration. No external power is needed at the remote RICC/ROCs. The RICC/ROCs draw their power from the computer's keyboard port (RICC/ROC PS/2, SUN) or from the USB port (RICC/ROC USB). Figure 6 and - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 19
ROC PS/2 are exactly the same. The following figure illustrates the RICC PS/2. Figure 8 - RICC PS/2 Connections You can connect the RICC/ROC PS/2 to a powered on computer, by performing the steps of the following procedure in order. To connect the RICC/ROC PS/2 to - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 20
order while the server is running may lead to the mouse malfunctioning until the server is rebooted. 2.6.2 Connecting a RICC/ROC USB The RICC/ROC USB supports Windows 98 SE and later, MAC, SUN, and SGI, and all modern Linux distributions. The connections for the RICC USB are exactly the same as - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 21
's video card. 2. Connect the Keyboard connector to the computer's Keyboard port. 2.7 Connecting to the Network Before powering on Smart 108/116 IP, you can connect the Smart 108/116 IP to the network. To connect the Connect the mouse's connector to the Smart 108/116 IP's Mouse port. User Guide | 21 - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 22
Installation Connecting the Power Supply 2.10 Connecting the Power Supply To connect the power supply to Smart 108/116 IP: 1. Using the power cord provided, connect Smart 108/116 IP to a socket outlet with a grounding connection. Only use the power cord supplied with the unit. 2. Switch on Smart 108 - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 23
the IP settings from the DHCP server. To keep the static IP address, you can disable DHCP, as explained in Section 3.3.2 on page 28. User Guide | 23 - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 24
Configuring the Network Logging Onto the Web Configuration Interface Figure 11 - Boot-Up Process Assigning Static IP Addresses for a Number of Units You can connect more than one Smart 108/116 IP to the same network. If there is no DHCP server, or you want to use static IP addresses, connect the - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 25
and in Password, type access (both lower case). 5. In Mode, select Configuration. 6. Click Enter. The Network configuration page appears with the Device tab open. User Guide | 25 - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 26
Configuring the Network Logging Onto the Web Configuration Interface Figure 14 - Network Configuration - Device Tab From the Configuration menu, you can configure the network, SNMP, Users, Switch Configuration, and Security settings. After making all configuration changes, you must click the - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 27
900; default Web interface TCP port is 443.) For client computer access from a secured LAN, the selected ports should be open for outbound communication. User Guide | 27 - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 28
to which Smart 108/116 IP is connected, to provide automatic IP assignment. Select manual IP address assignment - Clear the Enable DHCP checkbox to disable the DHCP, and then Settings Minicom's Centralized Management IP-based systems ensure secure control of servers and network devices, and power - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 29
Configuring Network SNMP Settings You can activate SNMP logging to provide support network monitoring. This will cause the Smart 108/116 IP to and control target servers, but cannot use advanced mouse settings and power cycle; cannot access the Web configuration interface 3.5.1 Adding a User To - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 30
Configuring the Network Configuring User Settings The Users page opens and displays the existing Users. 2. Click the Add button. Figure 16 - Users Page The Add User page appears. Figure 17 - Add User Page 3. Type a User Name and Password. The password must be at least six alphanumeric characters - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 31
Users page (see Figure 16), select a User and click the Edit button. The Edit User page appears, with the User's information in the parameters. User Guide | 31 - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 32
Configuring the Network Configuring the KVM Switch Figure 19 - Edit User Page 2. Change the Permission and/or Access as required. 3. To change the password, click . The Password parameter opens. In the upper textbox, type the new password; in the lower textbox, confirm the new password. You - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 33
Account Blocking, Password Policy, and Idle Timeout. You can choose a standard or high security level of password. The following table describes both these options. User Guide | 33 - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 34
Configuring the Network Performing Additional Configuration Operations Standard Security Policy High Security Policy At least six characters At least eight characters; must include at least one digit, one uppercase letter, and one of the following "special" characters or {} Must not include - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 35
button, and then You can upgrade the Smart 108/116 IP firmware to take advantage of new features. To upgrade firmware: 1. Download the firmware from Minicom's website at: http://www.minicom.com/phandlh.htm. User Guide | 35 - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 36
Configuring the Network Performing Additional Configuration Operations 2. Save the firmware file on the client computer. 3. In the toolbar, select . The Device Version Upgrade page appears, displaying the current firmware version on the device. Figure 23 - Device Version Upgrade Page 4. In - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 37
to restore the device settings. To reload a page: 1. In the Configuration page toolbar, click the button. The parameters are populated with the device settings. User Guide | 37 - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 38
Configuring the Network Saving Changes and Logging Out 3.10 Saving Changes and Logging Out Once you have completed configuration changes, you must save them. Changes to the SSL Certificate and Security pages require saving and restarting. Saving the configuration changes after changing the Device - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 39
Enter. The Configuration page opens. To log off: 1. In the screen toolbar, click the button. The Configuration screen is closed, and the session closes. User Guide | 39 - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 40
. If not, you can download and install Java from: http://www.java.com/en/download/index.jsp When using the Firefox browser, install the Minicom Firefox add-on. The following procedure describes how to log into a remote session from a client computer. To log onto a remote session: 1. Open your Web - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 41
switch that is connected directly to Smart 108/116 IP, appears with the Smart 108/116 IP toolbar. Toolbar Figure 31 - Remote Session Page User Guide | 41 - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 42
in Win98, NT or 2000 Align - for aligning the local mouse pointer with the remote target server mouse pointer Mouse Settings - for manually synchronizing the mouse pointers Server button. Pressing this button displays the connected servers. You can switch to a different server. Restore button. To - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 43
other users from logging into the same session. To set the session profile: 1. On the toolbar, select > Session Profile. The Session Profile window appears. User Guide | 43 - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 44
Conducting a Remote Session Setting the Session Profile Figure 33 - Session Profile Dialog Box 2. In Local Mouse Pointer, select one of the following options to set the appearance of the client computer mouse pointer: None - to hide the mouse pointer Dot - for the mouse pointer to appear as a - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 45
installed on your Smart 108/116 IP. This information can assist system administrators in troubleshooting and support. To verify Remote Presence Solutions information: 1. On the toolbar, select > About. environments, you may want to alter the settings to increase responsiveness. User Guide | 45 - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 46
Conducting a Remote Session Changing the Video Performance Settings Adaptive - Automatically adapts to the best compression and colors according to the network conditions. You can choose to display more colors for more fidelity, or less colors to reduce the volume of data transferred through the - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 47
video image Automatically adjusting the video image Manually changing advanced video settings 4.7.1 Refreshing the Video Image The video application is running on the target server's desktop. 4.7.3 Manually Adjusting Video Settings Although automatic adjustment of video generally optimizes the - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 48
revert to automatically adjusting the video settings, as explained in Section 4.7.2. To manually adjust the video settings: 1. On the toolbar, select > Advanced. The manual controls appear. Figure 37 - Manual Video Adjustments Controls 2. In Brightness and Contrast, use the scales to adjust - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 49
a Remote Session Managing Keyboard Sequences In H. Offset, select the starting position of each line on the displayed image. In V. Offset, select the vertical starting position of the displayed : 1. On the toolbar, click > Special Keys. The Special Key Manager box appears. User Guide | 49 - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 50
Conducting a Remote Session Managing Keyboard Sequences Figure 38 - Special Key Manager 2. Click the Add Predefined button. A list of existing sequences appears. Figure 39 - Add a Predefined Key Dialog Box 3. Select a key sequence and click OK. The sequence appears in the Special Key Manager box. 50 - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 51
. The Record Macro box appears (see Figure 40). The name of the key sequence to edit appears in the Label field. 2. Click Start Recording. User Guide | 51 - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 52
confirmation box appears. Figure 41 - Delete Key(s) Confirmation Box 4.9 Synchronizing Mouse Pointers For best mouse performance and superior customer experience, Minicom recommends that you set certain mouse settings in the target operating system. This applies to all targets running Windows, such - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 53
manually synchronize mouse pointers: 1. On the toolbar, select > Mouse Settings. The Mouse Settings box appears. Figure 42 - Relative Mouse Settings 2. In Operating System, from the dropdown menu, select the target's operating system. Instructions and sliders appear. 3. Follow the instructions and - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 54
Mouse Pointers Examples The following are examples of the instructions for two different target operating systems. After performing the instructions for the selected operating system, you should click OK are using, or have been informed to do so by customer support. 54 | Smart 108/116 IP - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 55
Max Rate, select the maximum mouse report rate. For Sun Solaris the default value is 20 in order to support older Sun versions. 4. Click OK. 4.9.2 Aligning the Mouse Pointers When accessing the target server, the mouse mouse pointer with the remote target device's mouse pointer. User Guide | 55 - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 56
case, go to Video Adjustment and try to eliminate the noise by automatically adjusting the video (see Section 4.7.2) and/or adjusting the bars in manual video adjust (see Section 4.7.3), and then performing the mouse calibration. If the mouse settings on the target server have been changed, you must - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 57
- Safe Mode Entering Safe Mode 5 Troubleshooting - Safe Mode From Safe mode, you can: Restore from the Web interface). Restore the device firmware - If during a firmware update there is a power failure and you can no longer access the system, you can restore the device firmware from Safe - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 58
Troubleshooting - Safe Mode Restoring Factory Defaults To enter Safe mode: 1. While powering up Smart 108/116 IP, press and hold down the Go Local button on the back panel of the unit for three to four seconds. - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 59
Troubleshooting - Safe Mode Restoring the Device Firmware To restore receive the Upgrade firmware required to restore the device firmware, contact Minicom Technical Support [email protected]. Save the Upgrade firmware on the hard disk of finishes, the following figure appears. User Guide | 59 - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 60
Troubleshooting - Safe Mode Restoring the Device Firmware Figure 51 - Upgrade Succeeded 3. Click Reboot to restart the unit. 60 | Smart 108/116 IP - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 61
locally, as well as how to upgrade the Smart 108/116 IP firmware (see Section 6.3) and troubleshoot problems that arise when updating the software (see Section 6.4). You can switch between the connected computers using either 116 IP. 2. Press Shift twice. The OSD Main window appears. User Guide | 61 - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 62
the OSD or return to a previous window within the OSD - Press Esc. 6.2.2 Selecting a Computer To select a computer: 1. Navigate to the desired computer line. OR Type the port number of the desired computer. 2. Press Enter. The selected computer is accessed. A Confirmation label appears showing which - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 63
OSD Settings window appears. Figure 53 - OSD Settings Window When the OSD is password protected (explained below), only the Administrator has access to the F2 settings window. 6.2.4 53), navigate to GENERAL so that the red line is on it, and press Enter. The General Settings window appears. User - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 64
By default, OSD access is not password protected. Only the Administrator can password-protect the OSD or disable password protection. To activate password protection: 1. In the General settings window (see Figure 54), navigate to the Security line. 2. Press the Space bar to toggle between Security - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 65
to the Hotkey line. 2. Press the lines on the OSD. When Autoskip is Off, the arrow keys access both active and inactive computer lines . To change the Autoskip setting: 1. In the General settings window (see Figure 54), navigate to the Autoskip line Language line. 2. line; a space - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 66
name The Keyboard settings To configure the ports settings: 1. In the OSD Settings window (see Figure 53), navigate to PORTS so that the red line is on it, and press Enter. The Ports Settings window appears. Figure 55 - Ports Settings Window Editing the Computer Name In the Ports Settings window - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 67
an entire line - Place the cursor at the beginning of the line, and keep the Space bar depressed until the line is erased. Figure 55), navigate to the KB column, and go to the line that you want to edit. 2. Press the Space bar to TIME so that the red line is on it, and press Enter. The Time Settings - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 68
computer is currently accessed T/O - the timeout period. When password protection is activated, you can automatically disable the Management keyboard, mouse, and window (see Figure 53), navigate to USERS so that the red line is on it, and press Enter. The Users Settings window appears. Figure 57 - - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 69
settings: 1. In the OSD Settings window (see Figure 53), navigate to SECURITY so that the red line is on it, and press Enter. The Security Settings window appears. Figure 58 - Security Settings Window . In this column, there can be one Administrator (A) password, one Supervisor (S) User Guide | 69 - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 70
Operating the Smart 108/116 IP Switching System Locally Using the OSD password, and six User (U) passwords. To change a user name or password: 1. In the Security Settings window, navigate to the desired row and column. 2. Type a new user name and/or password. User authentication is done solely via - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 71
screen image and Confirmation label appear. 3. Use the arrow keys to move the label to the desired position. 4. Press Esc to save and exit. User Guide | 71 - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 72
IP system. 6.3.1 Downloading Update Software and Latest Firmware The Update software and latest firmware for your system are located on our website at: http://www.minicom.com/phandlc.htm You can download any of the following firmware packages: 72 | Smart 108/116 IP - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 73
- Download a firmware package for RICC and ROC models (see the table on the Web page for the supported RICC/ROC models). Or, search for and download the specific RICC/ROC models with the correct firmware version. containing the software, and to the Smart 108/116 IP Switch Flash port. User Guide | 73 - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 74
IP Firmware Figure 60 - RS232 Cable 6.3.5 Installing the Software To install the Update software: 1. Download the software from the Support section of Minicom's website. 2. Install the software on the computer's hard drive. 6.3.6 Starting and Configuring the Update Software To start and configure - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 75
software on the computer's hard drive. 3. To change the Com Port from the Options menu, choose Com Port. The Communication Port Dialog box appears. User Guide | 75 - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 76
Operating the Smart 108/116 IP Switching System Locally Upgrading the Smart 108/116 IP Firmware Figure 62 - Communication Port Dialog box 4. Choose the Com Port that the RS232 Serial cable is connected to, and click OK. 6.3.7 Verifying the Version Numbers Before upgrading the firmware, you must - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 77
that it is switched off. 6.3.8 Obtaining New Firmware Download the latest firmware for your system from www.minicom.com. Updating the Firmware During the Update process, do not switch off any computer connected to the From the File menu, choose Open. The Open dialog box appears. User Guide | 77 - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 78
the status is now free. Click Start. 6. Check that the updated version number is correct by pressing . Manually Updating the RICC/ROCs You can manually update the RICC/ROCs after starting the Update software. To manually update the RICC/ROCs: 1. Select one or more ROCs.. 78 | Smart 108/116 IP - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 79
108/116 IP Switching System Locally Troubleshooting - Update Software 2. Press Options -> Advanced -> Manual Update. 3. Open the appropriate see page 66) 6.4 Troubleshooting - Update Software This section describes how to troubleshoot the following two problems that may arise when updating Guide | 79 - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 80
Operating the Smart 108/116 IP Switching System Locally Troubleshooting - Update Software If the electricity fails during the firmware update of the switch, a Communication Error message appears. Simply resume the firmware update by opening the - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 81
Both auto and manual modes Security Connections Weight Dimensions (H x D x W) Power input Operating temperature 40°C to 70°C / -40°F to 158°F 80% non-condensing relative humidity Specification Connections Power Product Weight Shipping Weight ROC PS/2 VGA - HDD15 KM - MiniDin6 System - RJ45 From - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 82
Technical Specifications Specification ROC PS/2 Dimensions (H x D x W) ROC USB 65 x 25 x 25 mm / 2.55 x 0.98 x 0.98 in 82 | Smart 108/116 IP - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 83
Rates Hz → 56 60 65 66 70 72 73 75 76 85 86 640x480 x x x x x x 720x400 x x 800x600 x x x x x x 1024x768 x x x x x x x 1152x864 x 1152x900 x x 1280x720 x 1280x768 x x 1280x960 x x 1280x1024 x x x x x 1600x1200 x x x x x User Guide | 83 - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 84
disconnected. Device internal hardware failure. Try disconnecting any other attached device and reboot. If problem persists, contact technical support. Power cycle command issued; only relevant when a special power-cycle product is attached to the device (for exmple, KBPower). User connected in view - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 85
changed. CONF_DG_CHANGED User Logged out from Config. CONF_LOG_OUT TCP Port was changed. CONF_TCP_PORT_CHANGED Remote Access type was changed. CONF_REMOTE_ACCESS_CHANGED CONF_SECURITY_CHANGED CONF_RESTORE_FACTORY_OK CONF_RESTORE_FACTORY_FAILED CONF_UPGRADE_OK CONF_UPGRADE_FAILED User Guide | 85 - Tripp Lite 0SU70032 | Owner's Manual for 0SU70030 / 0SU70032 KVM Switches 933207 - Page 86
201204198 • 933207_EN
![](/manual_guide/products/tripp-lite-0su70030-owners-manual-0su70030-0su70032-kvm-switches-933207-39cf627/1.png)
Smart 108/116 IP
User Guide
1111 W. 35th Street, Chicago, IL 60609 USA
www.tripplite.com/support