Uniden BCD325P2 Owners Manual - Page 44

Set Hold Time in seconds, Set Delay Time, Set Audio AGC, P25 Waiting Time

Page 44 highlights

Set Hold Time (in seconds) Sets (in seconds) the amount of time the scanner will scan the system before moving on to the next system. All (unlocked) channels will be scanned at least once regardless of this setting. The scanner moves to the next system after the hold time expires, any current transmission ends, and the channel delay time expires. The default setting is 0 seconds for each system. 1. Scroll to 'Set Hold Time' and press E/yes. 2. Enter the hold time (0-255 seconds) you desire and press E/yes to save and exit. Set Delay Time Sets the delay (in seconds) the amount of time the scanner stays on a channel after the transmission has ended before moving to the next channel. A negative delay will force a resume after that number of seconds. This setting applies to all channels in the system. You cannot set the delay on a 'per channel' basis. The default setting is 2 seconds. 1. Scroll to 'Set Delay Time' and press E/yes. 2. Scroll to the desired delay time (-10, -5, -2, 0, 1, 2, 5, 10, or 30 secs.) and press E/yes to save and exit. Set Audio AGC Allows you to turn the AGC feature on or off for the system. See also Adjust Audio AGC. 1. Scroll to 'Set Audio AGC' and press E/yes. 2. Scroll to 'Analog' and press E/yes to toggle on or off. 3. Scroll to 'Digital' and press E/yes to toggle on or off. 4. Press Menu to return. P25 Waiting Time This setting gives the scanner time to determine if a transmission is digital or analog. During this time, the scanner evaluates the signal and, if it detects P25, it immediately opens squelch. If P25 is not detected before the delay expires, the scanner opens squelch at the end of this delay. This prevents "false decode" problems (digital noise at the beginning of transmissions). The default setting is 400 ms. This setting only effects conventional channels with an Audio Type set to 'All'. 1. Scroll to 'P25 Wait Time' and press E/yes. 2. Set the Wait Time from 0 to 1000 ms and press E/yes. 44

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132

44
Set Hold Time (in seconds)
Sets (in seconds) the amount of time the scanner will scan the system before
moving on to the next system. All (unlocked) channels will be scanned at least once
regardless of this setting. The scanner moves to the next system after the hold time
expires, any current transmission ends, and the channel delay time expires. The
default setting is 0 seconds for each system.
1.
Scroll to ‘Set Hold Time’ and press
E/yes
.
2.
Enter the hold time (
0-255
seconds) you desire and press
E/yes
to save and
exit.
Set Delay Time
Sets the delay (in seconds) the amount of time the scanner stays on a channel after
the transmission has ended before moving to the next channel. A negative delay will
force a resume after that number of seconds. This setting applies to all channels in
the system. You cannot set the delay on a ‘per channel’ basis. The default setting is
2 seconds.
1.
Scroll to ‘Set Delay Time’ and press
E/yes
.
2.
Scroll to the desired delay time (-10, -5, -2, 0, 1, 2, 5, 10, or 30 secs.) and
press
E/yes
to save and exit.
Set Audio AGC
Allows you to turn the AGC feature on or off for the system. See also Adjust Audio
AGC.
1.
Scroll to ‘Set Audio AGC’ and press
E/yes
.
2.
Scroll to ‘Analog’ and press
E/yes
to toggle on or off.
3.
Scroll to ‘Digital’ and press
E/yes
to toggle on or off.
4.
Press
Menu
to return.
P25 Waiting Time
This setting gives the scanner time to determine if a transmission is digital or
analog. During this time, the scanner evaluates the signal and, if it detects P25,
it immediately opens squelch. If P25 is not detected before the delay expires,
the scanner opens squelch at the end of this delay. This prevents “false decode”
problems (digital noise at the beginning of transmissions). The default setting is 400
ms. This setting only effects conventional channels with an Audio Type set to ‘All’.
1.
Scroll to ‘P25 Wait Time’ and press
E/yes
.
2.
Set the Wait Time from 0 to 1000 ms and press
E/yes
.