Uniden BCD325P2 Owners Manual - Page 55

Set Location Info, P25 Waiting Time Motorola only

Page 55 highlights

Set Location Info Allows you program a location for the site so the scanner will enable/disable it for scanning with a GPS unit attached. See Set GPS Format first to set your position format. 1. Scroll to 'Set LocationInfo' and press E/yes. 2. At 'Set Latitude' press E/yes. 3. Enter the latitude and press E/yes. 4. At 'Set Longitude' press E/yes. 5. Enter the longitude and press E/yes. 6. At 'Set Range' press E/yes. 7. Enter the range (0.5 to 125 in 0.5 steps) and press E/yes. 8. At 'Set GPS Enable' press E/yes. 9. When this option is set to "On", the scanner will control L/O status of this site by position information received from a GPS. -- On - The L/O state of this site is automatically controlled by position information. -- Off - The L/O state of this site is not influenced by GPS. 10. Scroll to On or Off and press E/yes. 11. Press Menu to return. P25 Waiting Time (Motorola only) This setting gives the scanner time to determine if channels on Motorola mixed systems (not P25 only) have digital or analog transmissions. During this time, the scanner evaluates the received signal and, if it detects P25, immediately opens squelch. If P25 is not detected before the delay expires, the scanner opens squelch at the end of this delay. This prevents "false decode" problems (digital noise at the beginning of transmissions). The default setting is 400 ms. This setting only effects Motorola channels with an Audio Type set to 'All'. 1. Scroll to 'P25 Wait Time' and press E/yes. 2. Set the Wait Time from 0 to 1000 ms and press E/yes. Note: Any analog transmissions will lose the first part of the transmission, up to the wait time you set here. CREATING GROUPS To Create a New Group (no EDACS SCAT) press Menu. 1. At 'Program System' press E/yes. 55

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132

55
Set Location Info
Allows you program a location for the site so the scanner will enable/disable it for
scanning with a GPS unit attached. See Set GPS Format first to set your position
format.
1.
Scroll to ‘Set LocationInfo’ and press
E/yes
.
2.
At ‘Set Latitude’ press
E/yes
.
3.
Enter the latitude and press
E/yes
.
4.
At ‘Set Longitude’ press
E/yes
.
5.
Enter the longitude and press
E/yes
.
6.
At ‘Set Range’ press
E/yes
.
7.
Enter the range (0.5 to 125 in 0.5 steps) and press
E/yes
.
8.
At ‘Set GPS Enable’ press
E/yes
.
9.
When this option is set to “On”, the scanner will control L/O status of this site
by position information received from a GPS.
-
On
- The L/O state of this site is automatically controlled by position
information.
-
Off
- The L/O state of this site is not influenced by GPS.
10.
Scroll to On or Off and press
E/yes
.
11.
Press
Menu
to return.
P25 Waiting Time (Motorola only)
This setting gives the scanner time to determine if channels on Motorola mixed
systems (not P25 only) have digital or analog transmissions. During this time, the
scanner evaluates the received signal and, if it detects P25, immediately opens
squelch. If P25 is not detected before the delay expires, the scanner opens squelch
at the end of this delay. This prevents “false decode” problems (digital noise at the
beginning of transmissions). The default setting is 400 ms. This setting only effects
Motorola channels with an Audio Type set to ‘All’.
1.
Scroll to ‘P25 Wait Time’ and press
E/yes
.
2.
Set the Wait Time from 0 to 1000 ms and press
E/yes
.
Note: Any analog transmissions will lose the first part of the transmission, up
to the wait time you set here.
CREATING GROUPS
To Create a New Group (no EDACS SCAT) press
Menu
.
1.