Brother International HS-5300 Service Manual - Page 137
prescribed
View all Brother International HS-5300 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 137 highlights
(3) The PA motor does not rotate. Possible cause Connection failure of connector PA motor Driver circuit Step 1 2 Check Is the connection of connector P4 on the driver PCB correct? Disconnect connector P4 from the driver PCB. Measure the resistance between the connector pins of the PA motor by using a circuit tester. Do the measured resistances satisfy the prescribed value in the table below? Result NO NO YES Remedy Reconnect the connector. Replace the PA motor. Replace the driver PCB. Replace the Main PCB. P4-3 and P4-2 P4-3 and P4-5 P4-4 and P4-1 P4-4 and P4-6 Approx. 3 c (4) The carriage motor does not rotate. Possible cause Connection failure of connector P2. Step , Check 1 Are the connectors P2 and P3 on the driver PCB securely connected? , Result Remedy NO Connect them securely. Connection failure of connector P3. Carriage motor 2 Disconnect the connector P2 NO Replace the carriage from the driver PCB. motor. Driver circuit Measure the resistance between YES Replace the driver the connector pins of the PCB. carriage motor with a circuit Replace the Main tester. PCB. Does the measured resistance satisfy the value in the table below? P2-1 and P2-2 Approx.10 Q IV-3