HP 3PAR StoreServ 7400 2-node HP 3PAR Command Line Interface Reference (OS 3.1 - Page 271
Set Commands, setalert
View all HP 3PAR StoreServ 7400 2-node manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 271 highlights
22 Set Commands setalert DESCRIPTION The setalert command sets the status of system alerts. SYNTAX setalert new|ack|fixed {...|-a} AUTHORITY • Super, Service • Any role granted the alert_set right. NOTE: You need access to all domains in order to run this command. OPTIONS -a Specifies that the status of all alerts be set to new, acknowledged (ack), or fixed. If not specified, the specifier must be specified on the command line. SPECIFIERS ... Specifies that the status of a specific alert be set. This specifier can be repeated to indicate multiple specific alerts. Up to 99 alerts can be specified in one command. If not specified, the -a option must be specified on the command line. new|ack|fixed Specifies that the alert(s), as indicated with the specifier or with option -a, be set as new, acknowledged (ack), or fixed. RESTRICTIONS Access to all domains is required to run this command. EXAMPLES The following example sets the status of all system alerts as new: cli% setalert new -a NOTES Verify the status of alerts by issuing the showalert command. See "showalert" (page 350) for additional information. setalert 271