HP 3PAR StoreServ 7400 2-node HP 3PAR Command Line Interface Reference (OS 3.1 - Page 416
The power supply AC is oscillating.
View all HP 3PAR StoreServ 7400 2-node manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 416 highlights
The following example displays the detailed state of the power supplies: cli% shownode -ps Node PS -State- -Detailed_State- 0 0 OK OK 1 1 OK OK 2 2 OK OK 3 3 OK OK In the example above: • Node. The node ID. • PS. The power supply ID. • State. The power supply state. Values are as follows: ◦ OK. The power supply is operating normally. ◦ Failed. The power supply is operating abnormally. ◦ NotPresent. The power supply is missing. ◦ Degraded. The fan failure or battery state is not OK. • Detailed_State. The power supply detailed state. Values are as follows: ◦ invalid_bat_count. The power supply has an invalid battery count. ◦ dc_failed. The power supply DC failed. ◦ ac_failed. The power supply AC failed. ◦ fan_failed. The power supply fan failed. ◦ charger_overload. The power supply charger overloaded. ◦ battery_not_present. The power supply battery is not present. ◦ invalid_firmware. The power supply firmware is invalid. ◦ oscillating_presence. The power supply presence is oscillating. ◦ oscillating_dc. The power supply DC is oscillating. ◦ oscillating_ac. The power supply AC is oscillating. ◦ oscillating_fan. The power supply fan is oscillating. ◦ oscillating_charger. The power supply charger is oscillating. ◦ oscillating_bat. The power supply battery is oscillating. ◦ NotPresent. The power supply is not present. ◦ unknown. The power supply state is unknown. NOTES None. 416 Show Commands