HP 3PAR StoreServ 7400 2-node HP 3PAR Command Line Interface Reference (OS 3.1 - Page 334
Table 7 Event severity, WARNING, By default
View all HP 3PAR StoreServ 7400 2-node manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 334 highlights
Performs the same function as RawSpaceAlertFC, but should be used for Serial Attached SCSI type drives RemoteSyslog Enables or disables sending events as syslog messages to a remote system. A value of 0 disables the message, and a value of 1 enables the message. syslog messages are sent with a facility user and with event severities mapped to syslog levels such as: Table 7 Event severity Event Severity syslog Level fatal alert critical alert major crit minor err degraded warning info info RemoteSyslogHost Sets the IP address of the system to which events will be sent as syslog messages. The value must be a valid IP address. SparingAlgorithm Sets the sparing algorithm used by the admithw command. Valid values are Default, Minimal, Maximal, and Custom. MgmtOldPorts Enables or disables listening on the old management ports 2540 and 2550 (for SSL). The server now listens on ports 5782 and 5783 (for SSL). By default, the server also listens on the old ports unless they are disabled using this parameter. The value must be either enable or disable. Default ports 2540 and 2550 were deprecated in the 2.2.4 release and support for them will be removed in a future release. NOTE: The server must be restarted for changes made with the MgmtOldPorts parameter to take effect. RemoteCopyOldPort Enables or disables listening on the old TCP port 3491. The value must be either enable or disable. By default, Remote Copy links listen on both IANA registered port 5785 AND port 3491. WARNING! Changing this parameter will reset all Remote Copy links. This may cause Remote Copy targets to lose their connections temporarily. VVRetentionTimeMax [h|H|d|D] Specifies the maximum value that can be set for the retention time of a volume. is a positive integer value and in the range of 0 - 43,800 hours (1,825 days). Time can be optionally specified in days or hours providing either d or D for day and h or H for hours following the entered time value. The default value for is 14 days. To disable setting the volume retention time in the system, enter 0 for . UpgradeNote Sets a note that will be displayed when checkupgrade is run. To include spaces, enclose the value inside double quotes. To erase an existing note, specify "". Maximum length is 127 characters. 334 Set Commands