HP 3PAR StoreServ 7400 2-node HP 3PAR Command Line Interface Reference (OS 3.1 - Page 414
CPUSpeed, BusSpeed, PSState, Failed, NotPresent, Degraded, FanState, The fan is operating abnormally.
View all HP 3PAR StoreServ 7400 2-node manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 414 highlights
• CPUSpeed. The speed of the CPU in MHz. • BusSpeed. The bus speed of the CPU in MHz. cli% shownode -ps Power Supplies Node PS -PSState-- FanState ACState DCState -BatState- ChrgLvl(%) 0 0 NotPresent -- -- -- NotPresent 0 0 1 OK OK OK OK OK 100 1 0 OK OK OK OK OK 100 1 1 NotPresent -- -- -- NotPresent 0 In the example above: • Node. The node ID. • PS. The power supply ID. • PSState. The power supply state. Values are as follows: ◦ --. Cannot determine the state. ◦ OK. The power supply is operating normally. ◦ Failed. The power supply is operating abnormally. ◦ NotPresent. The power supply is missing. ◦ Degraded. There is a fan failure, or the battery state is not OK. • FanState. The power supply fan state. Values are as follows: ◦ --. Cannot determine the state. ◦ OK. The fan is operating normally. ◦ Failed. The fan is operating abnormally. • ACState. The state of the AC power. Values are as follows: ◦ --. Cannot determine the state. ◦ OK. Normal operation. ◦ Failed. Abnormal operation. • DCState. The state of DC power. Values are as follows: ◦ --. Cannot determine the state. ◦ OK. Normal operation. ◦ Failed. Abnormal operation. • BatState. The battery state. Values are as follows: ◦ OK. Normal operation. ◦ --. Cannot determine the state. ◦ Failed. Abnormal operation. 414 Show Commands