HP StorageWorks 8/80 Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000
HP StorageWorks 8/80 - SAN Switch Manual
View all HP StorageWorks 8/80 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks 8/80 manual content summary:
- HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 1
53-1000599-02 12 March 2008 Fabric OS Command Reference Manual Supporting Fabric OS 6.1.0 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 2
Fabric OS, File Lifecycle Manager, MyView, and StorageX are registered trademarks and the Brocade B-wing symbol, DCX, and SAN warranty, expressed or implied, concerning any equipment, equipment feature, or service offered or to be offered by Brocade. Brocade reserves the right .com/support/oscd. - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 3
San Jose, CA 95110 Tel: 1-408-333-8000 Fax Fabric OS Command Reference. Document Title Publication Number Summary of Changes Fabric OS Reference v2.0 53-0001487-03 Fabric OS Reference v2.2 53-0001558-02 Fabric OS Reference v2.3 53-0000067-02 Fabric OS Reference v3.0 53-0000127-03 Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 4
Reference 53-1000240-01 53-1000436-01 53-1000599-01 Fabric OS Command Reference 53-1000599-02 Summary of Changes Publication Date September 2006 15 Jun 2007 Added 13 new commands, Updated 23 commands with new options in support of v6.0. Removed 46 obsolete commands. Edit/revise ~ 150 commands - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 5
is organized xvii Supported hardware and software xvii What is new in this document xviii Document conventions xx Additional information xxii Getting technical help xxiv Document feedback xxv Chapter 1 Using Fabric OS Commands Understanding role-based access control 1 Understanding - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 6
74 chassisShow 75 cliHistory 77 configDefault 78 configDownload 80 configList 83 configRemove 84 configShow 85 configUpload 87 configure 90 dataTypeShow 97 date 98 dbgShow 99 defZone 100 diagClearError 102 diagDisablePost 103 vi Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 7
Fabric OS Command Reference 53-1000599-02 diagEnablePost 104 diagHelp 105 diagPost 106 diagRetry 107 diagSetBurnin 108 diagSetCycle 109 diagShow 110 diagSkipTests 111 diagStopBurnin 112 dbgShow - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 8
fdmiShow 190 ficonClear 191 ficonCupSet 192 ficonCupShow 194 ficonHelp 196 ficonShow 197 fipsCfg 203 firmwareCommit 206 firmwareDownload 207 firmwareDownloadStatus 212 firmwareKeyShow 215 firmwareKeyUpdate 216 viii Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 9
Fabric OS Command Reference 53-1000599-02 firmwareRestore 218 firmwareShow 219 fosConfig 220 fruReplace 222 fspfShow 223 fwAlarmsFilterSet 225 fwAlarmsFilterShow 226 fwClassInit 227 fwConfigReload 228 fwConfigure - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 10
325 licensePort 326 licenseRemove 328 licenseShow 329 linkCost 330 login 332 logout 333 lsanZoneShow 334 lsDbShow 336 memShow 339 miniCycle 340 msCapabilityShow 345 msConfigure 346 x Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 11
Fabric OS Command Reference 53-1000599-02 msPlatShow 348 msPlatShowDBCB 349 msPlClearDB 350 msPlMgmtActivate 351 msPlMgmtDeactivate 352 msTdDisable 353 msTdEnable 354 msTdReadConfig 355 myId 356 nbrStateShow - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 12
PortCfgQos 462 portCfgShow 464 portCfgSpeed 470 portCfgTrunkPort 471 portCfgVEXPort 472 portCmd 475 portDebug 479 portDisable 480 portEnable 481 portErrShow 482 portFlagsShow 483 portLedTest 484 xii Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 13
Fabric OS Command Reference 53-1000599-02 portLogClear 485 portLogConfigShow 486 portLogDisable 487 portLogDump 488 portLogDumpPort 489 portLogEnable 490 portLogEventShow 491 portLoginShow 492 portLogPdisc 493 portLogReset - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 14
slotPowerOff 601 slotPowerOn 602 slotShow 603 snmpConfig 606 spinFab 613 sshUtil 616 statsClear 620 stopPortTest 621 supportFfdc 622 supportFtp 623 supportSave 625 supportShow 629 xiv Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 15
Fabric OS Command Reference 53-1000599-02 supportShowCfgDisable 631 supportShowCfgEnable 632 supportShowCfgShow 633 switchBeacon 634 switchCfgPersistentDisable 635 switchCfgPersistentEnable 636 switchCfgSpeed 637 switchCfgTrunk 638 switchDisable 639 switchEnable - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 16
714 zoneRemove 715 zoneShow 716 Primary FCS commands Primary FCS commands 717 Control Processor Commands Commands supported on the standby CP 719 Command availability Command validation checks 721 Command RBAC permissions and AD types 722 xvi Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 17
use the command line interface to manage a Brocade SAN and Brocade switches. • Chapter 2, "Fabric OS Commands" provides command information. • Chapter 3, "Primary FCS commands" summarizes the subset of commands available when FCS policy is enabled. • Chapter 4, "Control Processor Commands" lists the - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 18
and corresponding help pages, refer to the Fabric OS Administrator's Guide. Although many different software and hardware configurations are tested and supported by Brocade Communications Systems, Inc. for Fabric OS 6.1.0, documenting all possible configurations and scenarios is beyond the scope of - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 19
default, netstat lists open sockets. For a list of all netstat options, refer to the UNIX man pages. Information that was deleted since this document was last released for Fabric OS v6.0.0. Help pages are removed from the manual when the associated commands are deprecated or no longer supported on - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 20
in the narrative portions of this guide are presented in mixed lettercase: for example, switchShow. In examples, command lettercase is all lowercase. If there are exceptions, this manual specifically notes those cases in which a command is case-sensitive. xx Fabric OS Command Reference 53-1000599 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 21
, and warnings The following notices and statements are used in this manual. They are listed below in order of increasing severity of potential hazards of SAN-specific terms, visit the Storage Networking Industry Association online dictionary at http://www.snia.org/education/dictionary. Fabric OS - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 22
the Fibre Channel Industry Association Web site: http://www.fibrechannle.org Optional Brocade features The Fabric OS 6.1.0 release includes all basic switch and fabric support software, as well as the following optionally licensed software that is enabled via license keys: • Brocade Ports on Demand - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 23
of 32 Gbit/sec that can support any number of devices. • Brocade Fabric Manager - Enables administration, configuration, and maintenance of fabric switches and SANs with host-based software. • Brocade Advanced Performance Monitoring - Enables performance monitoring of networked storage resources - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 24
For more information about licensed features refer to the Fabric OS Administrator's Guide. Getting technical help Contact your switch support supplier for hardware, firmware, and software support, including product repairs and part ordering. To expedite your call, have the following information - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 25
switch is inoperable, you can get the WWN from the same place as the serial number, except for the Brocade DCX. For the Brocade DCX, access the numbers number and as much detail as possible about your issue, including the topic heading and page number and your suggestions for improvement. Fabric OS - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 26
xxvi Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 27
licensed features and configuration and management procedures. Understanding role-based access control Fabric OS implements Role-Based Access Control (RBAC) to control access to all Fabric OS operations. Seven roles are supported, as defined in Table 1. Role definitions are guided by perceived - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 28
in this manual. Access is controlled by a switch-level password for each access level. The commands available through the CLI are based on the user's login role and the license keys used to unlock certain features. The Fabric OS CLI provides the following capabilities: • Access to the full range of - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 29
and a set of examples. The same information can be accessed by issuing help command on a Brocade switch or director. This command displays the help page for the specified command. For example, to display the help page for ad, type: switch:admin> help ad Fabric OS Command Reference 3 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 30
1 Using the command line interface 4 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 31
) services. Use this command to display, add, remove, change, enable or disable RADIUS/LDAP configuration. Switches running Fabric OS v5.2 or later use a local as well as a remote authentication mechanism for validating a login name. Supported authentication protocols include Password Authentication - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 32
. Ensure that FIPS is disabled before configuring LDAP. The following operands are optional: -p port Specifies the RADIUS or LDAP server port number. Supported range is 1 to 65535. The default port is 1812 for RADIUS authentication. The default port is 389 for LDAP authentication. This operand - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 33
Fabric OS v5.3.0 or later) The distinction between protocols is only applicable to the packets between a system and the RADIUS server. Between the user and system, passwords are always used. --remove server Removes the specified server from the configuration. The server must match one of the IP - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 34
are correct, the user authentication succeeds. If the user provides credentials from the switch database, RADIUS authentication would fail but login would still succeed through the switch database. Enables the current LDAP configuration as the primary AAA service and the switch-local database as - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 35
this command changes only the Defined Configuration in the transaction buffer. The --save default zone mode to "No Access" execute the following command sequence: switch:admin> ad --select AD0 switch:admin> defzone --noaccess switch:admin> cfgsave Refer to defZone help for more information. Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 36
supported: --activate arg Activates an Admin Domain. An Admin Domain is enforced only if it is in an activated state. AD0 is always in an activated state. By default, after the Admin Domain is enabled the defined configuration and enforces the defined configuration on all switches in the fabric. ad - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 37
operation to succeed. Not all existing user sessions to a deleted Admin Domain are number. The rename operation remains in the transaction buffer until you issue ad --apply or ad --save. --save Saves the outstanding Admin Domain transaction to the defined configuration on all switches in the fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 38
all Admin Domain information from the transaction buffer, defined configuration and effective configuration is displayed. --validate arguments Checks whether Admin Domain members are from a non-Admin Domain aware switch or the members do not exist in the fabric. The output is similar to ad --show - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 39
WWN member types. Benefits include: • Supports node or port WWNs. • End-device members, whose WWNs are used in switch. Any switch member specified in Domain ID format is converted into a switch WWN based on the current fabric information. Operations with switch list fail if the domain ID to switch - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 40
,5; 4,1" To apply all changes made to the Admin Domain configurations since --apply was last executed: switch:admin> ad --apply You are about to enforce the saved AD configuration. This action will trigger ad --apply to all switches in the fabric. Do you want to apply all admin domains (yes, y, no - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 41
the AD number: switch:admin> ad --select 12 To display all ADs: switch:admin> ad --show Current AD: 255 : AD255 Transaction buffer configuration no configuration Defined configuration AD: 1 : AD1 Active Device WWN members: 21:00:00:80:e5:12:8b:37; 21:00:00:80:e5:12:8b:55; Fabric OS - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 42
: AD255 Effective configuration AD: 1 : AD1 Active Device WWN members: Switch port members: Switch WWN members: 21:00:00:80:e5:12:8b:37; 21:00:00:80:e5:12:8b:55; 1,0; 1,1; 1,2; 1,3; 1,4; 1,5; 1,6; 1,7; 1,8; 1,9; 1,10; 1,11; 1,12; 1,13; 1,14; 1,15; 10:00:00:60:69:00:02:53; Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 43
members: 11:22:33:44:55:66:77:88*; AD Number: 5 AD Name: AD5 State: Inactive Device WWN members: Switch port members: 10:00:00:06:2b:12:69:ff*; 10:00:00:06:2b:12:68:3f; 1,343; AD Number: 50 AD Name: AD50 State: Active Fabric OS Command Reference 17 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 44
configuration AD Number: 50 AD Name: AD50 State: Active Device WWN members: Switch port switch:admin> ad --transshow Current transaction token is 26816 It is abortable switch:admin> ad --transshow There is no outstanding zoning transaction cfgSave, cfgTransShow, defZone, logout. 18 Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 45
• Add or delete N_Ports in Port group. • Display all policies and their status. • Enable or disable Auto Port configuration policy. • Enable or disable preferred Secondary N_Port policy. • Enable, disable, and manage Advanced Device Security (ADS) policy. Fabric OS Command Reference 19 53-1000599 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 46
a port group. • Auto Port Configuration (auto): When this policy is enabled, the AG enabled switch automatically detects available ports and map F_Ports to N_Ports. Auto Port Configuration is disabled by default. • Advanced Device Security (ADS) policy. This policy restricts access to the Fabric at - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 47
. All F_Port to N_Port mapping and port group configurations are ignored. ads Enables the advanced device security (ADS) policy. When enabled, this policy applies to all the ports on the switch. By default all devices have access to the fabric on all ports. --policydisable policy Disables the - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 48
with the specified new name. Port Group ID must not exceed 64 characters. --pgremove pgid Deletes the specified port group. The N_Ports in the Port Group that was deleted are moved to the default Port Group, which is pgid 0. --failoverenable N_Port Enables the failover policy for a given N_Port - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 49
secondary N_Port can be configured. The list of F_Ports to be mapped must be enclosed in quotation marks. Port numbers must be separated by ADS policy must be enabled for this command to succeed. --adsdel "F_Port [;F_Port2;...]" "WWN [;WWN2;...]" Fabric OS Command Reference 23 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 50
1e:35:9b:e7 Number of Ports : 16 IP Address(es) : 10.115.74.53 Firmware Version : v6.0.0 N_Ports : 4 F_Ports : 10 Policies enabled : pg Port Group information : PG_ID PG_Members PG_Name 0 1;3 pg0 2 0;2 SecondFabric Fabric Information : Attached Fabric Name N_Ports 10 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 51
, y, no, n): [no] y Access Gateway configuration has been restored to factory default 6. To enable ADS policy: switch:admin> ag--policyenable ads The policy ADS is enabled 7. To disable ADS policy: switch:admin> ag--policydisable ads The policy ADS is disabled Fabric OS Command Reference 25 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 52
enabled (1) or disabled (0). - PG_ID is the Port Group ID and PG_Name is the Port Group Name. 2. To clear all F_Ports mapped to the configured primary N_Port 0: switch retry the command switch:admin> ag --prefshow F_Ports Preferred N_Port 10;11 0 4;5;6 2 7;8;9 3 Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 53
> ag --failbackenable 0 Failback policy cannot be enabled since failover policy is disabled for port 0 switch:admin> ag --failbackenable 2 Failback policy is enabled for port 2 switch:admin> ag --failbackenable 3 Failback on N_Port 3 is not supported Fabric OS Command Reference 53-1000599-02 ag - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 54
pgshow PG_ID N_Ports PG_Name 0 0;2 pg0 3 1;3 FirstFabric AG Preferred port information commands 1. To display preferred port settings for F_Ports: switch:admin> ag --prefshow F_Ports Preferred N_Port 10;11 0 12;13 1 4;6 2 28 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 55
the Allow Lists of the F_Port[s] 2. To remove two devices from the lists of allowed devices for ports 1 and 9: switch:admin> ag --adsdel "3;9" "22:03:08:00:88:35:a0:12;22:00:00:e0:8b: 12 NO ACCESS 13 ALL ACCESS portCfgNPort, portCfgNPIVPort Fabric OS Command Reference 29 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 56
F_Ports and the configured N_Ports in the Access Gateway attached to the fabric shows the following information. Name The name of the Access Gateway. Ports The number of ports in the Access Gateway. Enet IP Addr The IP address of the Access Gateway. Firmware Current firmware running on the - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 57
/Remote Name 10:00:00:05:1e:04:06:ae 24 10.32.173.64 v6.0.0 local L5D2_B14_4024_1 See Also To display all Access Gateways attached to the fabric: switch:admin> agshow Worldwide Name Ports Enet IP Addr Firmware Local/Remote Name 10:00:00:05:1e:02:b7:2c 16 10.32.173.62 v6 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 58
another zone alias. This command changes the defined configuration. For the change to become effective, enable the zone configuration with the cfgEnable command. For the change to be preserved across switch reboots, save the zone configuration to nonvolatile memory with cfgSave. Note When FCS - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 59
port area or index numbers. • WWN Examples To create a zone alias: switch:admin> alicreate "array1", "2,32; 2,33; 2,34" switch:admin> alicreate "array2", "21:00:00:20:37:0c:66:23" switch:admin> alicreate "loop1", "4,5[0x02]; 6,7[0xEF]; 5,4" See Also aliAdd, aliDelete, aliRemove, aliShow Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 60
delete a zone alias. This command changes the defined configuration. For the change to become effective, enable the zone configuration with the cfgEnable command. For the change to be preserved across switch reboots, save the zone configuration to nonvolatile memory with the cfgSave command. Note - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 61
zone alias is deleted. This command changes the defined configuration. For the change to become effective, enable the zone configuration with the cfgEnable command. For the change to be preserved across switch reboots, save the zone configuration to nonvolatile memory with the cfgSave command. Note - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 62
configuration. Note When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands When invoked without operand, this command displays all zone configuration memory. The default value is 0. If no parameters are specified, all zone configuration information (both - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 63
the ISLs. Note that static routes are supported only with this policy. 3 Exchange-based routing policy (default). With this policy, the path chosen for an ingress frame is based on: • Ingress port on which the frame was received • FC address of the source fabric device (SID) for this frame • FC - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 64
successfully. switch:admin> switchenable switch:admin> aptpolicy Current Policy: 3 1(ap) 3 0(ap): Default Policy 1: Port Based Routing Policy 3: Exchange Based Routing Policy 0: AP Shared Link Policy 1: AP Dedicated Link Policy See Also dlsReset, dlsSet, dlsShow, switchDisable 38 Fabric OS - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 65
4-FIRMWARE and 5-FABRIC filters. This operand is required. --show Displays the current configuration. This operand is optional. --enable Enables all filters. --disable Disables all filters. Examples To configure the audit log filter, disable audit logging, and show the configuration: switch - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 66
to a specified value, only that DH group is enabled. Specifying "*" enables all DH groups 0, 1, 2, 3, and 4, in that order. This means that in authentication negotiation, the NULL DH group s given priority over all other groups. -h sha1 | md5 | all 40 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 67
. Disabling md5 access is required when configuring the system for FIPS. Refer to the Fabric OS Administrator's Guide for details on FIPS configuration. --policy Sets the switch authentication policy or device authentication policy. The following options are supported: -sw on|off|active|passive - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 68
DH-CHAP secrets on both switch and device. Otherwise, the F-port will be disabled during next F-port bring-up. ARE YOU SURE switch:admin> authutil --authinit 2,3,4 To disable md5 hash type for FIPS configuration: switch:admin> authutil --show AUTH TYPE HASH TYPE GROUP TYPE 42 Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 69
admin> authutil --set -h sha1 Hash is set to sha1. switch:admin> authutil --show AUTH TYPE HASH TYPE GROUP TYPE fcap,dhchap sha1 1 Switch Authentication Policy: PASSIVE Device Authentication Policy: OFF portShow, secAuthSecret authUtil 2 Fabric OS Command Reference 43 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 70
for a switch: switch:admin> bannerset "My banner" switch:admin> bannerSet Please input context of security banner (press "." RETURN at the beginning of a newline to finish input): Do not log into this switch if you are not an authorized administrator. . See Also bannerShow 44 Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 71
Use this command to display the contents of the banner. Operands none Examples To display the banner for a switch: switch:admin> bannershow Banner: Do not log into this switch if you are not an authorized administrator. See Also bannerSet Fabric OS Command Reference 45 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 72
In this example, from a switch with 128 ports, the member ports consist of ports 7, 13, 42, 84, 85, and 86. The final Member Ports bit set represents the embedded port (frames sent to be handled by firmware) and is typically set. See Also portRouteShow 46 Fabric OS Command Reference 53-1000599 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 73
beaconing for the specified slot is displayed. Examples To enable beaconing on slot 2, display the beaconing mode, then disable it: switch:admin> bladebeacon 2 1 switch:admin> bladebeacon 2 value = 1 switch:admin> bladebeacon 2 0 See Also switchShow Fabric OS Command Reference 47 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 74
Use this command to disable all user ports on a blade. All ports on the blade are taken offline. If the switch was connected to a fabric through this blade, the remaining switches reconfigure, and this switch will configure based on the other blade ports. The blade must be disabled before - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 75
enabled (except for persistently disabled ports); they might come online if connected to a device or remain offline if disconnected. If the switch is connected to a fabric through previously disabled ports, it rejoins the fabric. If this switch remains the principal switch at the end of the fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 76
Also 2 UNKNOWN VACANT 3 UNKNOWN VACANT 4 SW BLADE 2 ENABLED 5 CP BLADE 1 ENABLED 6 CP BLADE 1 ENABLED 7 SW BLADE 2 ENABLED 8 UNKNOWN VACANT 9 UNKNOWN VACANT 10 UNKNOWN VACANT bladeDisable, portDisable, portEnable, switchShow 50 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 77
details. Operands The following operand is required: slotnumber Specify a nonzero value for the slot number from which to clear burn-in errors. Examples To clear burn-in errors from slot 2: switch:admin> burninerrclear 2 See Also burninErrShow Fabric OS Command Reference 51 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 78
. Operands The following operand is required: slotnumber A nonzero value that specifies the slot number from which to display burn-in errors. Examples To display burn-in errors from slot 2: switch:admin> burninerrshow 2 See Also burninErrClear 52 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 79
port-count products, this is the chassis-persistent storage. The behavior of this command is determined by the manner in which the diagnostics daemon is configured : switch:admin> burninlevel -show Burnin level is 0. See Also burninErrShow, diagDisablePost, diagEnablePost, diagSetBurnin Fabric OS - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 80
blade in a specified slot. Command output includes the slot number, state, current run number, current command in the run, total commands in a switch:admin> burninstatus --slot 3 Slot State Status Run Cmd TotCmds PID 3 ABORT PASS 3 18 41 923 Script burnin See Also diagSetBurnin 54 Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 81
that an initiator sees are based on this configuration. The effective configuration is built when a specified zone configuration is enabled. Operands none Examples To display the effective zone configuration information: switch:admin> cfgactvshow Effective configuration: cfg: c4 zone: z3 33 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 82
memory with the cfgSave command. For the change to take effect, enable the configuration with the cfgEnable command. Note When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands The following operands are required: "cfgName" Specify a name for the - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 83
in nonvolatile memory for all the switches in the fabric. If no current zoning configuration exists, use the cfgSave command. If the default zone access mode is "No Access", then this command re-creates the default zoning objects. Note When FCS policy is enabled, this command can be issued only - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 84
see cfgShow). For the change to become effective, enable the configuration with the cfgEnable command. For the change to be preserved across switch reboots, save the configuration to nonvolatile memory with the cfgSave command. Notes When FCS policy is enabled, this command can be issued only from - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 85
"cfgName" Specify a name for the zone configuration to be deleted, in quotation marks. Examples To delete a zone configuration: switch:admin> cfgdelete "USA_cfg" See Also cfgAdd, cfgClear, cfgCreate, cfgDisable, cfgEnable, cfgRemove, cfgSave, cfgShow Fabric OS Command Reference 59 53-1000599 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 86
current zone configuration: switch:admin> cfgdisable You are about to disable zoning configuration. This action will disable any previous zoning configuration enabled. Do you want to disable zoning configuration? (yes, y, no, n): [no] y See Also cfgClear, cfgEnable, cfgSave 60 Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 87
action will replace the old zoning configuration with the current configuration selected. Do you want to enable 'USA_cfg' configuration (yes, y, no, n): [no] y zone config "USA_cfg" is in effect Updating flash ... See Also cfgClear, cfgDisable, cfgSave, cfgShow Fabric OS Command Reference 61 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 88
To enable fabric-wide McDATA safe zoning: switch:admin> cfgmcdatamode --enable safezoning To disable fabric-wide McDATA safe zoning: switch:admin> cfgmcdatamode --disable safezoning To enable fabric-wide McDATA default zoning: switch:admin> cfgmcdatamode --enable defaultzoning To disable fabric-wide - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 89
cfgShow). For the change to become effective, enable the configuration with the cfgEnable command. For the change to be preserved across switch reboots, save the configuration to nonvolatile memory with the cfgSave command. Note When FCS policy is enabled, this command can be issued only from the - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 90
the tests fail, an error displays and the configuration is not saved. This command ends and commits the current transaction. If a transaction is open on a different switch in the fabric when this command is run, the transaction on the other switch is automatically aborted. A message displays on the - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 91
is only effective when the Brocade switch/director is in McDATA fabric mode. Operands The cfgSaveActiveToDefined command has no operands. Examples Execute the cfgShow command to view defined and effective zoning configurations. switch:admin> cfgShow Default Zone: OFF Safe Zone: OFF Defined - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 92
sees in the fabric are based on this configuration. The effective configuration is built when a specific zone configuration is enabled and all error checking has been completed successfully. Notes When this command is executed after a zoning transaction was aborted on the local switch, it displays - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 93
:20:37:0c:71:df To display only configuration names: switch:admin> cfgshow "*" cfg: USA1 Blue_zone cfg: USA_cfg Red_zone; Blue_zone See Also cfgAdd, cfgClear, cfgCreate, cfgDelete, cfgDisable, cfgEnable, cfgRemove, cfgSave, cfgTransAbort, cfgTransShow Fabric OS Command Reference 67 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 94
the zone configuration to all switches in the fabric. Committed size Displays the size of the defined configuration currently stored in effective Admin Domain configurations. Note When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands The following - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 95
2 committed - 3124 bytes transaction - 0 bytes Number of ADs in Effective Configuration - 4 Each AD's Zone Database Size: cfgsize Info for AD Number:0 (AD Name: AD0, State=Active): committed - 242 bytes transaction - 0 bytes cfgsize Info for AD Number:1 (AD Name: AD1, State=Active - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 96
and the zone configuration database is restored to the state before the transaction was started. If a transaction is open on a different switch in the fabric when this command is run, the transaction on the other switch remains open and unaffected. Note When FCS policy is enabled, this command can - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 97
no, n): [no] y Clearing All zoning configurations... switch:admin> cfgtransshow Current transaction token is 271010736 It is abortable See Also cfgAdd, cfgClear, cfgCreate, cfgDelete, cfgDisable, cfgEnable, cfgRemove, cfgSave, cfgShow, cfgTransAbort Fabric OS Command Reference 71 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 98
parameters that are not compatible are restored to factory defaults. The configuration data includes, but is not limited to, routing, port swap, fabric, zoning, port configuration, passwords, security, Brocade Fabric Watch, management server, time server, SNMP, performance monitoring, and - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 99
2 Notes This command is retained for legacy reasons only. There are no separate chassis configuration options on the Brocade DCX backbone. By default the switch supports 384 ports in a single Fibre Channel domain. The chassisConfig command is not available on this platform. Brocade 48000 directors - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 100
, underscore or hyphen characters. This operand is optional; if omitted, the current chassis name displays. Examples To change the chassis name to "dilbert": switch:admin> chassisname dilbert switch:admin> chassisname dilbert See Also switchName 74 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 101
Consume Factor: -xxx 5 Part number (up to 14 characters): Factory Part Num: xx-xxxxxx-xx 6 Serial number (up to 12 characters): Factory Serial Num: xxxxxxxxxx 7 Operands none Examples To display all FRUs for a switch: switch:user> chassisshow Fabric OS Command Reference 75 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 102
ID: Part Num: Serial Num: . . . FAN Unit: 1 Header Version: Power Consume Factor: Factory Part Num: Factory Serial Num: Manufacture: Update: Time Alive: Time Awake: ID: Part Num: 1 -40 60- -777888 230-290-12370 (output truncated) See Also slotShow 76 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 103
a command is executed on the switch: • Timestamp • Username • IP address of the Telnet session as part of supportSave as the CH file. It is also saved persistently to compact flash if the switch panics. The maximum number of saved 1 See also none Fabric OS Command Reference 77 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 104
policies • User account passwords (includes all user config and all built-in accounts) • Switch PID format • Ethernet Link Mode Refer to the configure command for more information on default values for configuration parameters. Notes This command cannot be executed on an enabled switch. You must - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 105
See Also snmpConfig, configure, switchDisable, switchEnable configDefault 2 Fabric OS Command Reference 79 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 106
Domain users, refer to the Fabric OS Administrator's Guide for details regarding upload and download behavior The download might fail for some of the following reasons: • The switch has not been disabled. As of v5.2.0, configDownload can be invoked without disabling the switch for configuration - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 107
if one of the CPs is running a version of Fabric OS that does not support IPv6. Once a configuration file has been uploaded to an external system, it must NOT be manually edited before being downloaded, either to the same or another switch. Such an operation bypasses sanity checks for some - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 108
for large files. Do you want to continue [y/n]: y Activating configDownload: Switch is disabled configDownload complete: All config parameters are downloaded See Also configDefault, configList, configShow, configUpload, configure, configRemove 82 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 109
a list of configuration files stored on the local chassis: switch:admin> configlist -local config.txt config2.txt next_cfg.txt 25679 25679 20977 2007 Jan 02 15:16 2007 Jan 06 15:16 2007 Jan 18 15:16 See Also configDownload, configUpload, configShow, configRemove Fabric OS Command Reference - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 110
-local first_config.txt To remove a configuration file from an attached USB device without specifying a filename: switch:admin> configremove -USB File Name [config.txt]: second_config.txt See Also configDownload, configUpload, configList, configShow 84 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 111
and other common regular expression operators is not supported. Some configuration settings do not display when filtered. If configuration file: switch :admin> configshow -local File Name [config.txt]: config.txt [Switch cp7 Configuration uploaded on Aug 07 03:59:55] [FOS-Version: 6.0.0.0] Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 112
] [Licenses] [Chassis Configuration] [Configuration] acl.clear:0 ag.port.nfportfailback:0x0 ag.port.nfportfailover:0x0 ag.port.nfporttopo.0:0x0 ag.port.nfporttopo.1:0x0 ag.port.nfporttopo.10:0x0 [output truncated] To display selected content of the local configuration file: switch:admin> configshow - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 113
, no password should be provided on the command line. Instead, SCP prompts for the password if necessary. The SSH service is available switch. • The host IP address cannot be contacted. • The user does not have permission on the host. • The FTP server is not running on the host. The configuration - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 114
the Fibre Channel Router configuration. • The [iSCSI] section contains the iSCSI configuration. • The [Banner] section contains the banner header information. Notes It is not required to change the configuration if one of the CPs is running a version of Fabric OS that does not support IPv6 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 115
uploaded To upload a local configuration file from the command line forcing an overwrite: switch:admin> configupload -local -force config.txt configUpload complete: All config parameters are uploaded See Also configDefault, configDownload, configShow, configure Fabric OS Command Reference 89 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 116
configuration settings for the switch: • Switch fabric settings • Virtual channel parameters • F_Port login parameters • Zoning operation parameters • Remote State Change Notifications (RSCN) transmission mode • Arbitrated Loop Parameters • System Services Settings • Portlog Events enable default - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 117
for a WAN, if any, interconnecting the Fibre Channel islands. MAX_HOPS Maximum hops is an integer that denotes the upper limit on the number of hops a frame might have to traverse to reach any destination port from any source port across the fabric. Fabric OS Command Reference 91 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 118
By default, the switch can send Class F frames. When this option is turned on, Class F traffic is converted to Class 2 traffic before being transmitted. Per-frame Route Priority In addition to the eight virtual channels used in frame routing priority, support is also available for per-frame-based - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 119
symbol) Field Type Default Range Maximum logins per switch Number Maximum logins per port Logins per second Login stage interval (milliseconds) Number Number Number 16 * the max 1 to 126 * the number of ports max number of ports 126 1 to 255 0 0 to 100 0 0 to 10000 Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 120
-device for switch IP address or name change Type number number Default 1 0 Range 0 to 2 0 to 1 End-device RSCN Transmission Mode values are as follows: 0 RSCN only contains single PID 1 RSCN contains multiple PIDs 2 Fabric addresses RSCN Domain RSCN to End-device for switch IP address or - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 121
of crypto key Secure RPCd Callback secret Enforce secure Config Upload/Download Enforce signature validation for firmware Basic User Enabled Perform License Checking and Warning Allow Fabric Event Collection string string number string boolean boolean boolean boolean boolean not set not set 128 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 122
blade to be powered off. Examples To enable signed firmware download on a disabled switch: switch:admin> configure Configure... Fabric parameters (yes, y, no, n): [no] Virtual Channel parameters (yes, y, no, n): [no] F-Port login parameters (yes, y, no, n): [no] Zoning Operation parameters - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 123
used. Examples To display sample data streams you can use with diagnostics: switch:admin> datatypeshow Pattern type example BYTE_FILL WORD_FILL QUAD_FILL BYTE_NOT WORD_NOT QUAD_NOT BYTE_RAMP 00000000 11111111 22222222 33333333 See Also none Fabric OS Command Reference 97 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 124
enabled, this command can be executed only on the Primary FCS switch, and only the primary FCS switch can distribute the time stamp to all other switches in the fabric. The date specified is always the local switch time, taking into account daylight saving time and the time zone setup of the switch - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 125
the debug and verbosity levels. Module names are case-sensitive. This operand is optional. Examples To display information about a specific module named NS: switch:admin> dbgshow NS Module NS, debug level = 1, verbose level = 1 See Also setDbg Fabric OS Command Reference 99 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 126
is not enabled. When a user-specified zoning configuration is not enabled, Default Zone is in effect, allowing access to all devices. When a user-specified zone configuration is enabled, it overrides the Default Zone access mode. Notes This command must be run from the primary FCS switch. The - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 127
--noaccess primaryfcs:admin> cfgsave primaryfcs:admin> defzone --show Default Zone Access Mode committed - No Access transaction - No Transaction primaryfcs:admin> cfgactvshow Effective configuration: No Effective configuration: (No Access) none Fabric OS Command Reference 101 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 128
clear. If no operand is specified, the default is to clear all bad port flags. Examples To clear the diag software flag: switch:admin> diagclearerror 8 ERROR: DIAG CLEARERR Diagnostics Errors Cleared, port: 8/31 Err# 0120041 081F See Also none 102 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 129
Restrictions" and Appendix A, "Command Availability" for details. Operands none Examples To disable the POST during future power ons: switch:admin> diagdisablepost Config update Succeeded Diagnostic POST is now disabled. See Also diagEnablePost Fabric OS Command Reference 103 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 130
Restrictions" and Appendix A, "Command Availability" for details. Operands none Examples To enable the POST during future power ons: switch:admin> diagenablepost Config update Succeeded Diagnostic POST is now enabled. See Also diagDisablePost 104 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 131
diagnostics commands. Non-default settings require detailed knowledge of the underlying hardware and are intended for support personnel only. Contact support if you want to use these operands. Operands none Examples To display diagnostic command information: switch:admin> diaghelp bladepropshow - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 132
is displayed. Examples To enable and then disable the POST test: switch:admin> diagpost Diagnostic POST is currently disabled. switch:admin> diagpost 1 Config update Succeeded Diagnostic POST is now enabled. See Also diagDisablePost, diagEnablePost 106 Fabric OS Command Reference 53-1000599 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 133
Operands This command has the following optional operands: mode Specify 1 to enable, 0 to disable retry mode. -show Specify this operand to current retry mode value: switch:admin> diagretry -show Diagnostic Retry Mode is currently enabled. See Also none Fabric OS Command Reference 107 53- - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 134
installed switch:admin> diagsetburnin --slot 1 -current existing script is: /fabos/share/switchess.sh Burnin mode is Enabled. Removing all log files in /var/log for slot 1 Slot 1 burnin name is now /fabos/share/switchess.sh Config update Succeeded See Also burninErrShow, diagSetCycle 108 Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 135
configuration variables used by the specified script and enters an interactive session. Using the full parameters, variables can be updated noninteractively. In interactive mode, the current value, default burninLevel, diagSetBurnin, diagStopBurnin Fabric OS Command Reference 109 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 136
has the following optional operands: --slot number Specify which slot to operate on. If this option is not specified, the default slot 0 is used. The default slot is designed to operate on fixed-port-count products. By default, this command displays all user ports in the system. -uports itemlist - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 137
Synopsis diagskiptests [value | -show] Description Use this command to enable or disable the diagnostics skip test flags. The skip test flags To display the current skip test flags: switch:admin> diagskiptests -show Skip tests is 1. See Also none Fabric OS Command Reference 111 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 138
: --slot number Specify the Switch: 0, Error DIAG-MANUAL1, 1, " 1 Starting switchess ... Err# 0140042 0100:101:000:001:24:37: 0xc84 (fabos): Dec 20 08:57:27 Switch Switch: 0, Error DIAG-MANUAL1, 1, " 1 switchess: ABORT ... Err# 0140042 0100:101:000:002:26:41:1N See Also diagSetBurnin 112 Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 139
the debug and verbosity levels. Module names are case-sensitive. This operand is optional. Examples To display information about a specific module named NS: switch:admin> dbgshow NS Module NS, debug level = 1, verbose level = 1 See Also setDbg Fabric OS Command Reference 113 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 140
Device Connection Control Policy PWD Password Database and Password Configuration Policy AUTH E_Port and F_Port Authentication Policy FCS Fabric Configuration Server Policy IPFILTER IP-Filter Policy Each supported database has a switch-local configuration parameter that controls whether the - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 141
the FCS policy, and the Password database to all domains in the fabric that support the distribute feature: switch:admin> distribute -p "FCS;PWD" -d "*" To distribute the AUTH and FCS policies to all switches in the fabric that run v5.3.0 or later: switch:admin> distribute -p "AUTH;FCS" -d "*" To - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 142
fabric change occurs. Refer to dlsSet for a full description of load sharing. This command should be used only if devices connected to the fabric cannot : switch:admin> dlsreset Committing configuration...done. switch:admin> dlsshow DLS is not set See Also aptPolicy, dlsSet, dlsShow 116 Fabric OS - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 143
dlsSet 2 dlsSet Enables the dynamic load sharing (DLS) option. Synopsis dlsset Description Use this command to turn on DLS when a fabric change occurs. Routing is based on the incoming port and the destination domain. This means that all traffic coming in from a port (either from an E_Port or - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 144
to dlsSet for a description of load sharing. Notes DLS is not supported in certain routing policies. Refer to aptPolicy for more information on routing the current DLS option setting: switch:admin> dlsshow DLS is set See Also dlsSet, dlsReset 118 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 145
saved successfully Enter option 1 Display Domain Name Service (DNS) configuration 2 Set DNS configuration 3 Remove DNS configuration 4 Quit Select an item: (1..4) [4] 4 See Also configDownload, configUpload, firmwareDownload, ipAddrSet, ipAddrShow Fabric OS Command Reference 119 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 146
address used by the enclosure manager for this switch (indicates the physical position of the switch in the enclosure). connid The serial number of the switch used by the enclosure manager (not to be confused with the Factory Serial Number). conntype The connector type used by the enclosure - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 147
this command to clear all internal and external error log messages for all switch instances on this CP. Note The execution of this command is subject to Examples To clear the error log messages: switch:admin> errclear See Also errDump, errShow Fabric OS Command Reference 121 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 148
delimiters (with sample output): switch:admin> errdelimiterset -s "Start" -e "End" Start2003/03/10-09:54:03, [NS-1002], 1035,, ERROR, SWITCH43, Name Server received an invalid request from device 10:02:32:A3:78:23:23:End errDump, errFilterSet, errShow 122 Fabric OS Command Reference 53-1000599 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 149
; if omitted, the messages display in the normal order. -p Displays error logs from Fabric OS versions prior to v4.2. Examples To display the error log without pagination: switch:user> errdump Version: 4.4.0 2004/07/14-22:24:08, [HAMK-1003], 1,, INFO, switch1, Heartbeat up 2004/07/14-22 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 150
for an error log destination. A filter is set based on the severity level of the messages. If switch:admin> errfilterset console: filter severity = WARNING See Also To set the filter severity level for the console: switch:admin> errfilterset -d "console" -v "WARNING" errDump, errShow 124 Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 151
error log modules. Operands none Examples To display a list of all defined error log modules: switch:user> errmoduleshow Module IDs: 1 KT 2 UT 5 LOG 6 CDR 9 PIXE 10 EGR 13 PS 8 PISP 12 PIC 16 AUTH 20 CER 24 CONF See Also errDump, errShow Fabric OS Command Reference 125 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 152
omitted, the messages display in the normal order. -p Displays error logs from Fabric OS versions prior to v4.2. Examples To display the error log with pagination: switch:user> errshow Version: 4.4.0 2004/07/14-22:24:08, [HAMK-1003], 1,, INFO, switch1, Heartbeat up Type to continue, Q - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 153
closed; the serial port returns to the login: prompt. The exit command is an accepted synonym for logout, as is typing Ctrl-D at the beginning of a line. Operands none Examples To exit from a shell session: switch:admin> exit Connection to host lost. See Also logout Fabric OS Command Reference - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 154
to display the state of a port, relative to the fabric, as well as a list of pending commands. The following information displays: Port The port number. State The state of the port: P0 Port Offline P1 Port Online P2 ELP ACC Received P3 Link Reset Done I0 Trunk Initiator: EMT Sent - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 155
nbrWWN Neighboring switch's WWN nbrPort Neighboring switch's port lr_tid Link reset timer identifier number of the port to display, followed by a slash (/). portnumber Specifies the port number to display, relative to its slot for bladed systems. Use switchShow to list valid ports. Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 156
2 fabPortShow Examples See Also To display fabric port information: switch:admin> fabportshow 4/14 Fabric Port Information Port: State: List: List Count: Flags: nbrWWN: nbrPort: lr_tid: red_ports: 10 11 62 63 62 P3 0x10068418 0 0x280120 10:00:00:60:69:80:06:cf 5 0x1005dbd8, IDLE STATE Open - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 157
fabric commands. The SW_ISL (ISL ports) information displays the retry count for the following fabric commands: ELP Exchange Link Parameters EFP Exchange Fabric Parameters HA_EFP Exchange Fabric To display the retry count of Fabric OS commands: switch:user> fabretryshow SW_ILS E_Port ELP EFP - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 158
fabric log. By default, the fabric log is enabled. -e | --enable Enables the fabric log. -r size | --resize size Changes the maximum number of log entries. The given size has to be at least 2 and a power of 2; otherwise, the command fails. Examples To change the number of entries: switch 24 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 159
fabricLog 2 See Also switch:admin> fabriclog -r 64 Warning: This command will clear the logs. Are your sure you want to do the resize [y/n]? y switch:admin> fabriclog -s Time Stamp Input and *Action S, P Sn,Pn Port Xid fabPortShow, fabStatsShow Fabric OS Command Reference 133 53- - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 160
command to set principal switch selection mode for the switch. The implementation of the fabricPrincipal command is based solely on mechanisms specified in the Fibre Channel standards. These mechanisms provide a preference for a switch requesting to be the principal switch in a fabric, but they do - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 161
, if present in the fabric. Examples The following example illustrates a fabric of four switches. "sw180" is the Principal switch. Three of the switches are configured to run IP over Fibre Channel. switch:admin> fabricshow Switch ID Worldwide Name Enet IP Addr FC IP Addr Name 64: fffc40 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 162
:91 192.168.64.60 192.168.65.60 "sw60" The Fabric has 2 switches. To show additional details of the FC Router, if present: switch:admin> fabricshow -m Switch ID Name ENET IP Addr FC Router FC Router IP Addr Name 1: fffc01 fcr_sprint_01 10.33.59.224 160: fffca0 fcr_fd_160 0.0.0.0 10 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 163
Use this command to display the statistics for the fabric. The following information is displayed: • Number of times a switch domain ID has been forcibly changed • Number of E_Port offline transitions • Number of fabric reconfigurations • Number of fabric segmentations as a result of any of the - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 164
2 fabStatsShow Sec Incompatibility: 0 Sec Violation: 0 ECP Error: 0 Duplicate WWN: 0 Eport Isolated: 0 See Also fabRetryShow 138 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 165
the fabric switch state structure information. This command is strictly for debugging; it is not intended as a user command. ME Timer: 0x10069610, IDLE STATE Principal Domain: 2 Upstream Port: 64 Principal Wwn: 10:00:00:60:69:80:06:ce Principal Priority: 0x2 Flags: 0x40 me retry count - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 166
" for details. Operands This command has the following operand: unit Specifies the number of the fan unit to disable. Examples To disable a fan unit: switch:admin> fandisable 1 Fan unit 1 has been disabled See Also fanEnable, fanShow 140 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 167
2 fanEnable Enables a fan unit. Synopsis fanenable unit Description Use this command to set a previously disabled fan unit back to the default RPM speed number to enable. Examples To enable a fan unit: switch:admin> fanenable 1 Fan unit 1 has been enabled See Also fanDisable, fanShow Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 168
switch type and number of fans present. Operands none Examples To display information on the fans in the system: switch:admin> fanshow Fan #1 is OK, speed is 2721 RPM Fan #2 is OK, speed is 2657 RPM Fan #3 is OK, speed is 2700 RPM See Also chassisShow, fanDisable, fanEnable, psShow 142 Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 169
Restrictions" and Appendix A, "Command Availability" for details. Operands Examples none To reboot the Control Processor without executing power-on self test (POST) on startup: switch:admin> fastboot See Also diagDisablePost, diagEnablePost, reboot Fabric OS Command Reference 143 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 170
slot. The blade reverts to FCIP (default). --show Displays the FC fastwrite configuration including the FC fastwrite-enabled ports. The slot number is an optional parameter. If the slot number is not specified, the command displays the FC fastwrite-enabled ports on the entire system. slot This - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 171
-cycling of the affected blade to take effect and may take up to 5 minutes to complete. Non-bladed switches will be rebooted. In all cases, data traffic on all the ports (FC and GbE) of the blade will be disrupted. Continue (Y,y,N,n): [ n] portcfg Fabric OS Command Reference 145 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 172
MBIST and LBIST -unit number Specifies the GbE port to test. By default, all GbE ports in the specified slotnumber are used. Valid number values include: 0 GbE port 0 1 GbE port 1 2 All GbE ports Examples To run all tests on slot 7 and GbE port 1: switch:admin> fcipchiptest --slot 7 -unit - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 173
When a failure is detected, the test might report one or more of the following error messages: CHIP_TEST_ERR CHIP_TEST_CHIP_INIT_ERR CHIP_TEST_IMAGE_VER_ERR CHIP_TEST_TIMEOUT_ERR CHIP_TEST_HEARBEAT_ERR CHIP_TEST_INVALID_RESULT See Also fcipPathTest Fabric OS Command Reference 147 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 174
to display a short description of fibre channel over IP (FCIP) commands. FCIP commands require an FCIP license. Operands none Examples To display FCIP command information: switch:admin> diaghelp fciphelp fastwritecfg portcfg portcmd portshow Configure FC fastwrite feature Create/Delete a new - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 175
test progresses until the specified number of frames are transmitted on each port. The default value is 100. -length data_length Specifies the data length of the frames used in the test. The default is 1,024; the maximum is 2,112 FC frames and 8,196 data packets. Fabric OS Command Reference 149 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 176
to select or to bypass data compression for the test. By default, data compression is used. This setting is applicable only to Examples To run the test on slot 2 with PHY loopback sending 10 frames: switch:admin> fcippathtest --slot 2 -path 2 -nframes 10 Running fcippathtest Test Complete: Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 177
which is used for any LUN query from this switch. Examples To display the LUN information: switch:user> fclunquery Target Index: 1 Target Node WWN: 50:05:07:65:05:03:f9:39 Target Port WWN: 50:05:07:65:05:83:f9:39 Target Pid: 144e8 Number of LUNs returned by query: 1 LUN ID: 0x00 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 178
. The ELS Echo request elicits an ELS Echo response from a port identifier in the fabric and is useful for validating link connectivity. The source and destination port identifiers can be specified as a 24-bit Fibre Channel port identifiers, port World Wide Names, or node World Wide Names. The two - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 179
one device that accepts the request and another device that does not respond to the request: switch:admin> fcping 0x020800 22:00:00:04:cf:75:63:85 Source: 0x20800 Destination: 22:00 5 frames timeout Round-trip min/avg/max = 0/0/0 usec ping Fabric OS Command Reference 153 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 180
Use this command to clear the debug information logged by the Fibre Channel Protocol daemon (FCPD). Note The execution of this command is the FCPD debug information log: switch:admin> fcplogclear See Also fcpLogDisable, fcpLogEnable, fcpLogShow 154 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 181
Use this command to disable the logging of debug information by the Fibre Channel Protocol daemon (FCPD). Notes The execution of this command is subject the FCPD debug information log: switch:admin> fcplogdisable See Also fcpLogClear, fcpLogEnable, fcpLogShow Fabric OS Command Reference 155 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 182
Use this command to enable Fibre Channel Protocol daemon (FCPD) logging. Debug information logging is enabled by default. Note The execution of Examples To enable the FCPD debug information log: switch:admin> fcplogenable See Also fcpLogClear, fcpLogDisable, fcpLogShow 156 Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 183
various stages during the Fibre Channel Protocol daemon (FCPD) debug information log: switch:admin> fcplogshow Time Stamp Event Port file&lineno arg0 arg1 1 536 2 :0 :0 :0 :0 [output truncated] See Also fcpLogClear, fcpLogDisable, fcpLogEnable Fabric OS Command Reference 157 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 184
Fibre Channel Protocol daemon (FCPD) device probing information for the devices attached to the specified F_Port or FL_Port. This information includes the number of successful logins and SCSI INQUIRY commands sent over this port , portLogShow 158 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 185
2 fcpRlsShow Displays the Fibre Channel Protocol (FCP) Read Link Status (RLS) information. Synopsis fcprlsshow [slotnumber/]portnumber Description Use this command to display the FCP RLS information for the specified F_Port or FL_Port. This information describes the number of loss-of-signal - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 186
fcrbcastconfig --enable -f fabric id fcrbcastconfig --disable -f fabric id fcrbcastconfig --help Description Use this command to enable or disable the broadcast frame option or to display the current configuration. If no operands are specified, this command displays the usage. By default, frame - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 187
To display the new configuration: switch:admin> fcrbcastconfig --show Broadcast configuration is disabled for: fid 2 fid 128 SEE ALSO bcastshow, portRouteShow fcrBcastConfig 2 Fabric OS Command Reference 161 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 188
details. This command is supported only on Brocade FR4-18i blades and Brocade 7500 platforms. Operands This command has the following operands: --slot slotnumber Specifies the slot number on which the diagnostic operates. The default is 0 and operates on fixed-port-count products. -testtype type - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 189
fcrChipTest 2 switch:admin> fcrchiptest --slot 7 -unit 1 -testtype 0 Running fcrchiptest Test Complete: fcrchiptest Pass 1 of 1 Duration DMA_READ_TIMEOUT CHIP_INIT_TIMEOUT BIST_TIMEOUT BIST_FAIL fcrPathTest, miniCycle, portLoopbackTest Fabric OS Command Reference 163 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 190
interactively prompts for the following parameter: Backbone Fabric ID A fabric ID uniquely identifies a fabric in FC Router configurations. The backbone fabric is the fabric attached to the U_Ports-for example, E/F_Ports-of this switch. The backbone fabric ID must be unique across all FC Router - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 191
FC Router backbone fabric. The existing syntax is maintained for IPv6 support. When IPv6 addresses are not configured, the output of port number for the EX_Port. FID The fabric ID of the EX_Port. Neighbor Switch Info (WWN, enet IP, name) The WWN, Ethernet IP address, and switch name of the switch - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 192
maximum LSAN count for all the FCR switches in the same backbone that support this feature. Verify the configured maximum limit against the LSANs configured using the fcrResourceShow command. Note The default LSAN count maximum of 3000 is the Fabric OS v5.2 default). It allows v5.2 to run on the - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 193
practice is, therefore, to enter the same information for all the FCR switches in the backbone that support this command. This command is also used to specify FC Router pairs that can talk to each other. All edge fabrics connected to a defined pair of FCRs are allowed to import devices each other - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 194
entry of the pair of FIDS. If no longer specified, the edge fabric assumes the default behavior. --apply -lsan | -fcr | -all Applies the information from from the import/export setup. Examples For the following example, assume that the backbone has the following online edge fabrics (FIDs): 1, 2, - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 195
default/dynamic binding in the backbone where online fabrics are: 1, 2, 4, 5, 7, 8, 10: switch:admin > fcrlsanmatrix --fabricview -lsan LSAN MATRIX is activated Fabric ID 1 Fabric ID 2 4 5 4 7 10 19 Default dd:d0:07 08f002 78 10:32:16:91:24:dd:d0:05 09f001 78 4e0000 Imported 82 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 196
--apply -lsan To view all the static and the default/dynamic fabric binding in the backbone: switch:admin > fcrlsanmatrix --fabricview -lsan LSAN MATRIX is activated Fabric ID 1 Fabric ID 2 52 78 52 82 78 82 Default LSAN Matrix: 57 91 Diagnostics Error message (1): "LSAN Matrix - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 197
on all the FCR switches in the backbone. • In a dual backbone configuration, use fcrlsanmatrix --fabricview on the FCR switches to confirm that the shared edge fabric FIDs have the same access in both backbones. Refer to the Fabric OS Message Reference manual for further diagnostic information - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 198
number of frames transmitted is not equal to the number of frames received. 8. Repeat steps 2 through 7 for all ports present until one of the following conditions is met: a. The number , 0x78, 0x78, 0x78, ... CRPAT 0xbc, 0xbc, 0x23, 0x47, ... 172 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 199
number of frames are transmitted on each port. The default value is 10. Examples To test slot 2 with FC Router FPGA Serdes loopback sending 10 frames: switch:admin INIT - PORTDIED - STATS - TIMEOUT - XMIT fcrChipTest, miniCycle, portLoopbackTest Fabric OS Command Reference 173 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 200
physical devices include physical devices that are configured to be exported from fabrics attached to this FC Router's EX_Ports. The physical devices are listed by fabric. The -f and -w operands allow searching for physical devices based on fabric ID or port World Wide Name. "No device found" is - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 201
fcrPhyDevShow 2 Examples To display the physical devices relevant to this FC Router: fcr:admin> fcrphydevshow Device WWN Physical Exists PID in Fabric 2 10:00:00:00:c9:2b:6a:68 c70000 3 50:05:07:65:05:84:09:0e 0100ef 3 50:05:07:65:05:84:0b: - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 202
. If the configuration is altered, then care must be taken to ensure consistency across all FC Routers attached to the same edge fabric. If no operand is specified, the command displays the following information: importedFID The imported fabric ID of the proxy device. devWWN The port World Wide - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 203
not exist in any proxy device slot." is displayed if the WWN does not exist in any slot for the specified edge fabric. Examples To display the persistent proxy device configuration: switch:admin> fcrproxyconfig Imported FID 002 002 002 002 003 Device WWN 50:05:07:65:05:84:08:d7 50:05 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 204
device appears to the fabric as a real Fibre Channel device. It has a name server entry and is assigned a valid port ID. Proxy device information is available only for proxy devices that are presented by FC Routers on the same backbone fabric as this FC Router. The default output displays only - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 205
fcrProxyDevShow 2 Examples To display the physical devices relevant to this FC Router: switch:admin> fcrphydevshow Device WWN Physical Exists PID in Fabric 2 10:00:00:00:c9:2b:6a:68 c70000 3 50:05:07:65:05:84:09:0e 0100ef 3 50:05:07:65:05:84:0b: - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 206
a translate domain slot. A slot is the port number and AL_PA combination. The slot-to-device WWN association is persistently stored. Phantom Node WWNs The maximum versus the currently allocated phantom switch node WWNs. The phantom switch requires node WWNs for fabric-shortest-path-first (FSPF) and - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 207
switch:Admin> fcrresourceshow Daemon Limits: LSAN Zones: LSAN Devices: Proxy Device Slots: Max Allowed Currently Used 1000 22 10000 1208 10000 2 Phantom Node WWN: Phantom Port , fcrProxyDevShow, fcrRouteShow, lsanZoneShow, switchShow Fabric OS Command Reference 181 53-1000599- - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 208
the default cost is used for that IFL. To set the cost, make sure that admin is enabled for the EX_Port/VEX_Port with portCfgEXPort or portCfgVEXPort. The cost can be set only on a disabled port. If no operands are specified, this command displays the current link costs for all ports on the switch - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 209
To display the cost of one EX_Port: switch:admin> fcrrouterportcost 7/10 Port Cost 7/10 1000 To set the cost of an EX_Port: switch:admin> fcrrouterportcost 7/10 10000 See Also switchShow, fcrRouteShow, portCfgEXPort fcrRouterPortCost 2 Fabric OS Command Reference 183 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 210
EX_Port. NR_Port technology enables EX_Ports to exchange traffic across an intermediate fabric. NR_Ports are addressable entities on the backbone fabric and have port IDs relevant to the backbone fabric. Because cascaded backbone/intermediate fabrics are currently not supported, an NR_Port provides - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 211
configures a translate (xlate) domain ID for both the EX_Port-attached fabric and the backbone fabric . Any changes you intend to make using this command should be issued on the switches to which the edge fabrics are directly attached. Note The execution of this command is subject to Admin Domain - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 212
:00:51:e1:30:30:0f:05 To set the preferred domain ID of the translate domain created in fabric 2 that represents remote fabric 3 to a value of 8: switch:admin> fcrxlateconfig 2 3 8 xlate domain already configured, overwrite?(n) y To clear the preferred domain ID of the translate domain created in - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 213
the fabric-wide consistency policy. Switches can be locally configured to allow or reject a security policy. Supported policies are Switch Connection Control (SCC), Device Connection Control (DCC), Password (PWD), Fabric Configuration Server (FCS), Fabric Element Authentication (AUTH), and IP Filter - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 214
of the form "SCC:S;DCC;FCS". To set the fabric-wide policy to NULL (default) or no fabric-wide consistency, use the policy Set "". Supported policies are Switch Connection Control (SCC), Device Connection Control (DCC), and Fabric Configuration Server (FCS). All members specified in a given policy - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 215
FDMI cache: switch:admin> fdmicacheshow Switch entry for domain 3 state: known version: v310 wwn: 10:00:00:60:69:90:03:c7 HBAs: 10:00:00:00:c9:25:9b:96 Ports: 1 10:00:00:00:c9:25:9b:96 Total count of devices on the switch is 1 See Also fdmiShow Fabric OS Command Reference - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 216
Supported Speed: 0x00000001 Port Speed: 0x00000001 Frame Size: 0x00000800 HBA attributes: Node Name: 20:00:00:00:c9:25:9b:96 Manufacturer: Emulex Network Systems Serial Number: 0000c9259b96 Model: LP9000 Model Description: Emulex LightPulse LP9000 1 Gigabit PCI Fibre Channel - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 217
To clear the RLIR database: switch:user> ficonclear RLIR successfully clear local RLIR Database. To clear the RNID database: switch:user> ficonclear RNID successfully clear not current entries from local RNID Database. See Also ficonHelp, ficonShow Fabric OS Command Reference 191 53-1000599 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 218
timeout value is rounded down to the closest value divisible by 10. For example, an MIHPTO timeout value of 86 defaults to 80. Examples To enable FMS mode for the switch: switch:admin> ficoncupset fmsmode enable fmsmode for the switch is now Enabled 192 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 219
the mode register for the switch: switch:admin> ficoncupset modereg ASM 1 Active=Saved Mode bit is set to 1 See Also To set the MIHPTO value to 60 seconds: switch:admin> ficoncupset MIHPTO 60 MIHPTO has been changed to 60 seconds ficonCupShow ficonCupSet 2 Fabric OS Command Reference 193 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 220
display FICON-CUP (Control Unit Port) parameters for a switch. Note The execution of switch: switch:user> ficoncupshow fmsmode fmsmode for the switch: Enabled To display the mode register for the switch: switch:user> ficoncupshow modereg POSC UAM ASM DCAM ACP HCP 1 0 1 1 1 0 194 Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 221
To display the ASM bit in the mode register for the switch: switch:user> ficoncupshow modereg ASM ASM --1 See Also To display the MIHPTO value for the CUP: switch:user> ficoncupshow MIHPTO MIHPTO for the CUP: 60 seconds ficoncupset ficonCupShow 2 Fabric OS Command Reference 195 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 222
FICON support commands with descriptions. Operands none Examples To display a list of FICON commands: switch:admin switch ficoncupshow Displays FICON-CUP parameters for a switch ficonhelp N/A ficonshow Displays contents of the specified FICON management database See Also none 196 Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 223
domain ID. Fabric WWN Displays the fabric WWN. Flag Indicates if the node is valid, not valid, or not current. Flag values are as follows: 0x00 Indicates the node ID of the storage port for RNID switch for SwitchRNID is valid. 0x10 Indicates the node ID of the channel port is valid. 0x20 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 224
port state Listener PID Same as PID. Listener Port Type Same as Port Type. Listener Port WWN Displays the channel HBA port . Byte BB 0x0a Switch. Byte CC 0x00 Port number. It is dynamically support not specified. 0xa0 Reserved. 0xc0 Reserved. 198 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 225
registered with the switch. 0xID CHIPID if channel port has registered with the switch. 0xPN If switch has registered with the channel, PN represents the FL port number. Part Number Displays the switch chassis part number. PID Displays the 24-bit Fibre Channel port address in 0xDDAAPP format - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 226
channel or storage CU port World Wide Name associated with the device HBA. Sequence Number Displays the sequence number of the self-describing node. Serial Number Displays the switch serial number. Switch node WWN Displays the switch node World Wide Name. Switch Port fabric Specify fabric for - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 227
Number: 0000000169CA tag: 052e } } To display the local and remote LIRR database: switch:admin> ficonshow LIRR fabric {Fmt Type PID Listener Port WWN Switch Port WWN Listener Type 0x18 N 502b00 50:05:07:64:01:00:15:8d 20:2b:00:60:69:80:1e:4e Conditional 0x18 N 502e00 50:05:07:64:01:40 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 228
: switch:user> ficonshow ILIR { {FRU Failure [2]: Power Supply[2] failure occurred on Mon Jan 13 12:11:38 2003 Fmt Protocol Domain Fabric WWN Switch WWN 0x18 FICON 80 10:00:00:60:69:33:33:33 10:00:00:60:69:80:1e:4e FRU part number: FRU serial number: 23000000602 FL2L0001071 {Listener Port - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 229
while FIPS is enabled. The system must be rebooted for FIPS mode changes to take effect. Refer to the Fabric OS Administrator's Guide for information on configuring your system for FIPS 140-2 level 2 compliance. FIPS mode cannot be modified through configDownload. FIPS is not supported on all - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 230
permit state. HTTP port number for the policy is in permit state. RPC port number for the policy is in permit state. SNMP is not in read only mode. Bootprom access is enabled. FIPS mode cannot be configured at this time 204 Fabric OS Command Reference 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 231
To enable FIPS after prerequisites have been met: switch:admin> fipscfg --enable fips FIPS mode has been set to : Enabled Please reboot the system switch:admin> fipscfg --show FIPS mode is : Enabled See Also none fipsCfg 2 Fabric OS Command Reference 205 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 232
commit a new version of the firmware: switch:admin> firmwarecommit Validating primary partition... Doing firmwarecommit now. Please wait ... Replicating kernel image FirmwareCommit completes successfully. See Also firmwareDownload, firmwareRestore 206 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 233
, the BP firmware is downloaded to the BP processors if there is a mismatch between the BP and CP firmware. By default, firmwareDownload performs a full install, autoreboot, and autocommit. These modes are selectable only in single CP (-s) mode, in which case autoreboot is OFF by default. Fabric OS - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 234
single CP mode. This mode supports selectively enabling or disabling a full install, autoreboot, and autocommit on bladed and non-bladed systems. On enterprise-class platforms, this mode supports upgrading a single CP. When downloading the main Fabric OS firmware, this option disables autoreboot - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 235
this option may cause traffic disruption for some switches in the fabric. Examples To download the firmware to an HA switch over a network: switch:admin> firmwaredownload 192.168.166.30,johndoe,/pub/dist/release.plist,12345 The following BP blades are installed in the system. Slot Name Versions - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 236
(all, or slot numbers) [all]: Server Name or IP Address: 192.168.32.10 Network Protocol (1-auto-select, 2-FTP, 3-SCP) [1]: User Name: userfoo File Name: /home/userfoo/dist/release.plist Password: To download SAS firmware without version compatibility checking: switch:admin> firmwaredownload -c Type - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 237
be reached by the switch. • The user does not have permission on host. • The password is not specified correctly. • Indicated firmware does not exist on the host, or is not in the right format, or is corrupted. • The FTP or SSH service is not running on host. • The platform is not supported by the - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 238
The following example shows the status of the firmwaredownload for an SAS image to the blades in slot 2 and 7. switch:admin> firmwaredownloadstatus [1]: Thu Jul 28 00:30:49 2007 Slot 2 (SAS): Firmware is being downloaded to the blade. It may take up to 30 minutes. [2]: Thu Jul 28 00:30:49 2007 Slot - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 239
command has completed successfully. Use firmwareshow to verify the firmware versions. To display the status of a firmware download on a chassis: switch:admin> firmwaredownloadstatus [1]: Mon Dec 19 18:40:19 2007 Slot 6 (CP1, active): Firmware is being downloaded to standby CP. This step may take up - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 240
successfully. [11]: Mon Dec 19 18:55:39 2007 Slot 5 (CP0, active): Firmware has been downloaded successfully on Standby CP. [12]: Mon Dec 19 18:55:46 2007 Slot 5 to verify the firmware versions. See Also firmwareCommit, firmwareDownload, firmwareRestore, firmwareShow 214 Fabric OS Command Reference - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 241
on every switch as a part of the Fabric OS installation. The presence of a firmware key does not imply that the firmware signature is checked during firmwareDownload. Signed Firmware Download must be enabled before the public key can be used for signature validation. Use the configure command to - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 242
switch as a part of the Fabric OS installation. The presence of a firmware key does not imply that the firmware signature is checked during firmwareDownload. Signed Firmware Download must be enabled before the public key can be used for signature Use the configure command to enable Signed Firmware - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 243
updated. To update the public key using the interactive method: switch:admin> firmwarekeyupdate Server Name or IP Address: 192.168.21.34 User Name: johndoe File Name: /pub/dist/pubkey.pem Network Protocol(1-auto-select, 2-FTP, 3-SCP) [1]: Password: Updating the public key, please wait... Public key - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 244
to restore the former active Fabric OS firmware image. This command can downloaded firmware becomes active. If you then do not want to commit the firmware and want to restore the former firmware Examples To restore the former active firmware image: switch:admin> firmwarerestore Restore old image to - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 245
Fabric OS versions on all firmware partitions in the system. Synopsis firmwareshow Description Use this command to display the FOS, SAS, and SA firmware versions. The command shows the firmware the firmware versions in a Brocade director with FA4-18 blades installed in slot 2 and 7: switch:admin> - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 246
. "FC Routing service is already enabled." This means that the FC Routing service is already enabled. iSCSI Enables the iSCSI service on the switch. By default, iSCSI is disabled. iSNSC Enables the iSNSC service on the switch. By default, iSNSC is disabled. 220 Fabric OS Command Reference - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 247
FC Routing service is enabled To enable the iSCSI service: switch:admin> fosconfig --enable iscsi iSCSI service is enabled To disable the iSCSI service: switch:admin> fosconfig --disable iscsi iSCSI service is disabled See Also fcrConfigure, iscsiCfg, iscsiPortCfg, isnscCfg, switchShow Fabric OS - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 248
supported value, specifying the replacement of the WWN card. Examples To replace the World Wide Name card: switch: Switch WWN Card Removal and Replacement document. Do you wish to continue [y/n]? y Backing up WWN card data, please wait about 25 seconds for further instruction. Please install - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 249
FSPF protocol. Domain number of local switch. State of the local switch. TRUE if the domain of the local switch is currently confirmed. Bit map of all the ISL. Bit positions correspond to the default areas of the ports. Bit 0 refers to default area of the switch, bit 1 refers to default area 1, and - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 250
2 fspfShow Examples To display FSPF protocol information: switch:admin> fspfshow version = 2 domainID = 131 switchOnline = TRUE lsrDelayCount = 1 ddb_sem = 0x1003e6e8 fabP: event_sch = 0x0 See Also bcastShow, topologyShow, uRouteShow 224 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 251
has the following operand: mode Specify 1 to enable the alarms, 0 to disable the alarms. If no operand is specified, the default value is 0 (alarms deactivated). This operand is optional. Examples To enable alarms in Fabric Watch: switch:admin> fwalarmsfilterset FW: Alarms are already disabled - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 252
Domain Restrictions" and Appendix A, "Command Availability" for details. Operands none Examples To display the status of alarm filtering in Fabric Watch: switch:user> fwalarmsfiltershow FW: Alarms are enabled switch:user> fwalarmsfiltershow FW: Alarms are disabled See Also fwAlarmsFilterSet 226 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 253
this command to initialize all classes under Fabric Watch. The command should only be used after installing a Fabric Watch license to start licensed Fabric Watch classes. Refer to fwConfigure for a list of classes. Notes This command requires a Fabric Watch license. The execution of this command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 254
Fabric Watch configuration. This command should only be used after downloading a new Fabric Watch configuration file from a host. Notes This command requires a Fabric reload the saved Fabric Watch configuration: switch:admin> fwconfigreload fwConfigReload: Fabric Watch configuration reloaded See - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 255
modifies the Fabric Watch configuration. Synopsis fwconfigure fwconfigure --enable --port portNumber fwconfigure --disable --port portNumber Description Use this command to display and modify threshold information for the Fabric Watch configuration. Switch elements monitored by Fabric Watch are - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 256
changes Zone changes FabricQL Fabric logins SFP state changes Link loss (E-port) Sync loss (E-port) Signal loss (E-port) Protocol error (E-port) Invalid words (E-port) Invalid CRCS E-port) RXPerformance (E-port) TXPerformance (E-port) State Changes (E/VE-port) Utilization (VE-port) Packet Loss - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 257
platforms support fans or power supplies. If you attempt to configure values for these items the following displays: "ERROR: No threshold available. This command has the following optional operands: --enable --port portNumber Enables all thresholds associated with a certain port. Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 258
portNumber Disables all thresholds associated with a certain port. Examples To configure thresholds in Fabric OS mode: switch:admin> fwconfigure 1 : Environment class 2 : SFP class 3 : Port class 4 : Fabric class 5 : E-Port class 6 : F/FL Port (Optical) class 7 : Alpa performance Monitor class - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 259
21 C In_Range 2 envTemp002 enabled 24 C inBetween Sat Oct 7 10:01:53 2006 21 C In_Range 1 : refresh 2 : disable a threshold 3 : enable a threshold 4 : advanced configuration 5 : return to previous page Select choice => : (1..5) [5] 5 See Also fwClassInit, fwConfigReload, fwShow Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 260
2 fwFruCfg fwFruCfg Displays or modifies FRU state alert configuration. Synopsis fwfrucfg [--show] Description Use this command to configure field-replaceable unit (FRU) states and actions. Based on these configuration settings, Fabric Watch generates action when a FRU state changes. To - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 261
Reload Fabric Watch configuration Configure FRU state and notification Configure Fabric Watch Email Alert Create a report with detailed port information Show availability monitor information Set port persistence time Set boundary & alarm level to custom Set boundary & alarm level to default Show - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 262
Alert 3 : Enable Email Alert 4 : Send Test Mail 5 : Set Recipient Mail Address for Email Alert 6 : Relay Host IP Configuration 7 : Quit Select an item => : (1..7) [7]1 Config Show Menu 1 : Environment class 2 : SFP class 3 : Port class 4 : Fabric class 5 : E-Port class 6 : F/FL Port (Optical - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 263
Email Alert 3 : Enable Email Alert 4 : Send Test Mail 5 : Set Recipient Mail Address for Email Alert 6 : Relay Host IP Configuration 7 : Quit Select an item => : (1..7) [7]5 Mail Config Menu 1 : Environment class 2 : SFP class 3 : Port class 4 : Fabric class 5 : E-Port class 6 : F/FL Port (Optical - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 264
calculated based on the following contributors: Port Errors: LFA Number of link loss occurrences exceeded limit for time period LSY Number of requires a Fabric Watch license. Port errors are not supported for virtual ports and SFP errors are not applicable for virtual ports. The execution - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 265
002:53 005 U OFFLINE 080:24 006 U OFFLINE 080:24 007 U OFFLINE 080:24 To retrieve a port detailed report for a switch configured with an IPv4 address: switch:user> fwportdetailshow Port Detail Report Switch Name: switch IP address: 10.202.78.24 Port Exception report [by All] Report - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 266
See Also To retrieve a port detailed report: switch:user> fwportdetailshow --s h Port Detail Report Switch Name: switch IP address: 192.168.163.237 Port Exception report [by Healthy] Report time: 05/21/2007 11:22:58 PM --------Port-Errors SFP-Errors---- Port# Type State Dur(H:M) LFA - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 267
includes total uptime, total downtime, number of faulty occurrences, and total percent of downtime for each port. Notes This command requires a Fabric Watch license. Operands none Examples To generate a SAM report on an eighty-port switch: switch:user> fwsamshow Total Total Down Total - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 268
0 0 0 100 37 U 0 0 0 100 38 U 0 0 0 100 39 U 0 0 0 100 40 T 99 0 0 0 41 T 99 0 0 0 42 T 100 0 0 0 43 T 99 0 100 77 U 0 0 0 100 78 U 0 0 0 100 79 U 0 0 0 100 See Also portShow, switchShow 242 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 269
be set with this option. Port persistence time is the time period in which a port must be persistently in a state before being recognized as such. Examples To set message levels and port persistence time: switch:user> fwset --port --persistence 18 See Also fwShow Fabric OS Command Reference 243 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 270
. Fabric Watch uses two types of settings: factory default settings and user-defined custom settings. • Factory default settings are automatically enabled. These settings vary depending on hardware platform, and cannot be modified. • For some settings, you can create custom threshold configurations - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 271
a threshold 3 : enable a threshold 4 : advanced configuration 5 : return to Custom Unit Time base Low High BufSize Default C 0 60 base 15 : change inBetween alarm 6 : change custom low 16 : apply threshold alarm changes 7 : change custom high 17 : cancel threshold alarm changes Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 272
2 fwSetToCustom 8 : change custom buffer 18 : return to previous page 9 : apply threshold boundary changes 10 : cancel threshold boundary changes Select choice => : (1..18) [18] See Also fwSetToDefault, fwConfigure, fwHelp, fwShow 246 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 273
. Fabric Watch uses two types of settings: factory default settings and user-defined custom settings. • Factory default settings are automatically enabled. These settings vary depending on hardware platform and cannot be modified. • For some settings, you can create custom threshold configurations - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 274
enabled 24 C inBetween Thu Feb 14 01:21:36 2008 24 C In_Range 4 envTemp004 enabled 23 refresh 2 : disable a threshold 3 : enable a threshold 4 : advanced configuration 5 : return to previous page Select choice is set at : Custom Unit Time base Low High BufSize Default C 0 60 10 Custom C - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 275
10 : cancel threshold boundary changes Select choice => : (1..18) [18] See Also fwSetToCustom, fwConfigure, fwHelp, fwShow fwSetToDefault 2 Fabric OS Command Reference 249 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 276
, refer to the help page for fwConfigure or consult the Fabric Watch Administrator's Guide. In Access Gateway mode, only the following class thresholds are supported. F/FL Port (Copper) class threshold is supported only on Embedded platforms. TABLE 14 Access Gateway mode classes Class Environmental - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 277
Fan 1 2576 RPM envFan002 Env Fan 2 2518 RPM envFan003 Env Fan 3 2481 RPM switch:user> fwshow 1 : Show class thresholds 2 : Detail threshold information 3 : Show port persistence time 4 : Quit Select an item => : (1..4) [3] 2 Enter Threshold Name : [] envFan001 Env Temperature 1: Monitored - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 278
time: switch:admin> fwshow --port --persistence FW: current port persistence time = 18s To display ports that have all thresholds disabled: switch:user> fwShow --disable --port Port Threshold Status 1 disabled See Also fwClassInit, fwConfigReload, fwConfigure, fwSet 252 Fabric OS - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 279
commands typed into the shell; the oldest commands are replaced as new ones are entered. Operands none Examples To display previous shell commands: switch:admin> h 1 version 2 switchshow 3 portdisable 2 4 portenable 2 5 switchshow See Also none Fabric OS Command Reference 253 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 280
in place. Refer to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands none Examples To disable the High Availability feature: switch:admin> hadisable HA is disabled See Also haEnable 254 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 281
failover would be disruptive. • IP and Fibre Channel addresses configured for the switch. • Additional internal HA state switch:admin> hadump Local CP (Slot 6, CP1): Active, Cold Recovered Remote CP (Slot 5, CP0): Standby, Healthy HA enabled, Heartbeat Up, HA State synchronized SWITCH Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 282
227.64 Ethernet Subnetmask: 255.255.240.0 Fibre Channel IP Address: 220.220.220.64 Fibre Channel Subnetmask: 255.255.240.0 CP0 Ethernet IP Address: 10.32.227.66 Ethernet Subnetmask: 255.255.240.0 Host Name: cp0 Gateway IP Address: 10.32.224.1 CP1 Ethernet IP Address: 10.32.227.67 Ethernet Subnetmask - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 283
be in place. Refer to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands none Examples To enable the High Availability feature: switch:admin> haenable HA is enabled See Also haDisable Fabric OS Command Reference 257 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 284
mode, the command aborts. Notes When High Availability (HA) synchronization is enabled and the CPs are in sync, the port traffic light does not flash during the failover, even while traffic is continuing to flow. This command is supported only on dual-CP systems. The execution of this command is - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 285
command may not be supported on non-bladed systems. Operands none Examples To display CP status, first on a healthy standby CP and then on a faulty standby CP: switch:admin> hashow Local CP (Slot 6, CP1): Active, Cold Recovered Remote CP (Slot 5, CP0): Non-Redundant Fabric OS Command Reference - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 286
2 haShow See Also switch:admin> hashow Local CP (Slot 6, CP1): Active, Warm Recovered Remote CP (Slot 5, CP0): Standby, Failed Backplane PCI fail, severity: CRITICAL HA enabled, Heartbeat Up, HA State not in sync haDisable, haEnable, haFailover 260 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 287
1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Examples To enable the HA state synchronization: switch:admin> hasyncstart HA State synchronization has started See Also haFailover, haShow, haSyncStop Fabric OS Command Reference 261 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 288
to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands none Examples To disable the HA state synchronizing process: switch:admin> hasyncstop See Also haFailover, haShow, haSyncStart 262 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 289
commands for which help is available. At the end of the list are some additional commands which to the current user; command availability may vary depending on: • Login user role • License key switch:admin> help help See Also diagHelp, fwHelp, licenseHelp, perfHelp, routeHelp, zoneHelp Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 290
(WWN) cards. The type of FRU supported depends on the hardware platform. Each history record switch:admin> historylastshow POWER SUPPLY Unit 2 Inserted at Tue Aug 14 15:52:10 2001 Factory Part Number: 60-0001536-02 Factory Serial Number: 1013456800 Records: 11 See Also historyShow 264 Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 291
which records the insertion and removal of FRUs on a switch or chassis. This command supports two modes of handling new log entries once the history log: switch:admin> historymode History Mode is: Rotating. See Also historyLastShow, historyShow Fabric OS Command Reference 265 53-1000599- - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 292
Available FAN Unit 3 Inserted at Tue Aug 14 10:23:45 2001 Factory Part Number: 20-123456-12 Factory Serial Number: 1013456800 WWN Unit 1 Inserted at Tue Aug 14 11:03:45 2001 Factory Part Number: 40-0000031-03 Factory Serial Number: 1013456800 266 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 293
Tue Aug 14 13:59:50 2001 Factory Part Number: 60-0001604-02 Factory Serial Number: FP00X600128 POWER SUPPLY Unit 2 Inserted at Tue Aug 14 15:52:10 2001 Factory Part Number: 60-0001536-02 Factory Serial Number: 1013456800 Records: 11 See Also historyLastShow Fabric OS Command Reference 267 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 294
which the plug-in can be downloaded. Operands none Examples To display the Java plug-in version: switch:admin> httpcfgshow Current HTTP configuration javaplugin.version = 1,5,0,6 javaplugin.homeURL = http://java.sun.com/update See Also httpCfgSet 268 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 295
specified process or about all processes running on the local switch. One line is displayed per process. Fields displayed or stopped Z a defunct ("zombie") process The effective user ID number of the process The process ID of the process The . Fabric OS Command Reference 269 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 296
the following operand: processID Specifies the process name or process ID for the process to display. Examples To display information about process ID 433: switch:admin> i 433 F S UID PID PPID C PRI NI ADDR SZ WCHAN TTY TIME CMD 000 S 0 433 1 0 69 0 - 1283 5c64 ? 00:00:02 fabricd See Also - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 297
group. --disable Disables the ICL for the specified port group. --help Displays command usage. Examples To disable the ICL for ports 16-31: switch:user> iclcfg --disable 8/1 To enable the ICL for ports 16-31: switch:user> iclcfg --enable 8/1 Fabric OS Command Reference 271 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 298
to an operating mode not supported by the network equipment to which it is attached may result in an inability to communicate with the system through its ethernet interface. It is recommended that you only use this command from the serial console port. 272 Fabric OS Command Reference 53-1000599 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 299
[yes] y Committing configuration...done. To force the link for the eth0 interface from auto-negotiation to 10 Mbps half-duplex operation, when entering this command through the serial console port: switch:admin> ifmodeset eth0 Auto-negotiate (yes, y, no, n): [yes] n Force 100 Mbps / Full Duplex (yes - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 300
network interface and 0 is the physical unit. Examples To display the link operating mode for the "eth0" Ethernet interface: switch:admin> ifmodeshow eth0 Link mode: negotiated 100baseTx-HD, link ok MAC Address: 00:60:69:D0:24:40 See Also ifModeSet 274 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 301
: idbP Pointer to IDB. nghbP Pointer to neighbor data structure. ifNo Interface number. masterPort Port number of the trunk master port, if present, of the trunk group of which this port is a part. defaultCost Default cost of sending a frame over the ISL connection to this interface. cost - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 302
of Hello frames to the neighbor switch. nHloOut Number of Hello frames transmitted to the neighbor switch. attLsuOut Number of attempted transmissions of LSUs to the neighbor switch. nLsuOut Number of LSUs transmitted to the neighbor switch. 276 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 303
number and port number are specified, this command displays the interface information for all ports on the switch (including non-E_Ports). Examples To display FSPF interface information: switch:user helloTID = 0x1008c7a0 dbRtxTID = 0x1008c7d8 Fabric OS Command Reference 277 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 304
inactTo helloTo rXmitTo nCmdAcc nInvCmd nHloIn nInvHlo nLsuIn nLsaIn attHloOut nHloOut attLsuOut nLsuOut attLsaOut nLsaOut = 0x1008c848 = 80000 = 2000 = 5000 = 7 = 0 = 2 = 0 = 2 = 3 = 2 = 2 = 3 = 3 = 2 = 2 See Also nbrStateShow, portShow, switchShow 278 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 305
but there is no check that it is turned off. The configuration is reset. If you have a defined or effective configuration and default zoning is on, when you disable the switch and change to McDATA Open Fabric mode, you are informed that all configurations will be lost and that the system will reboot - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 306
mode is disabled, all configuration parameters return to their default states and can be modified using the configure command. For information on supported hardware platforms and procedures regarding OS v5.2.1_NI to v6.0.0 migration, refer to the Fabric OS Administrator's Guide. The execution of - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 307
change to take effect. Do you want to continue? (yes, y, no, n): [no] y To enable McDATA Open Fabric mode on a disabled switch: switch:admin> interopmode 3 McDATA Open Fabric mode is enabled The switch effective configuration will be lost. The system will reboot to allow the change to take effect - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 308
domain_id Description Use this command to reset the user-defined IOD delay settings to default values (-1). This command resets IOD delay values for a specified domainID that was previously configured with the iodDelaySet command. When IOD delay is not configured or reset, the system uses its own - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 309
must be enabled on the switch before you can set the IOD delay value.Enabling IOD ensures that frames are always delivered in-order, even after fabric topology . The valid range for this value is 10 500 ms. The default value is -1. domain_id Specifies the domain ID to which the IOD delay - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 310
the IOD delay settings for all domains in the fabric. Examples To Display the IOD delay setting for domain 5: switch:user> ioddelayshow 5 omain - Iod Delay 5 - 20 To display IOD settings for all domains in the fabric: switch:user> ioddelayshow 5 omain - Iod Delay (ms) 1- 2 5 - 20 10 - 20 20 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 311
Use this command to disable in-order delivery enforcement on the local switch. IOD is disabled by default, and can only be disabled after it has been enabled with the iodSet command. Disabling IOD allows faster re-routing after a fabric topology change, but it may cause out-of-order delivery of - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 312
2 iodSet iodSet Enables the in-order delivery (IOD) option. Synopsis iodset Description Use this command to enforce in-order delivery of frames during a fabric topology change. In a stable fabric, frames are always delivered in order, even when the traffic between switches is shared among - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 313
the IOD option is enabled or disabled. The default setting for IOD is disabled. Operands none Examples To display the current setting of the IOD option: switch:admin> iodshow IOD is not set See Also iodReset, iodSet, iodDelaySet, iodDelayReset, iodDelayShow Fabric OS Command Reference 287 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 314
command prompts for the Ethernet IP address, Ethernet subnetmask, Fibre Channel IP address, and Fibre Channel subnetmask. When setting the CP, the command prompts for the host name, Ethernet IP address, Ethernet subnetmask, and Gateway IP address. Valid switch and CP numbers depend on the platform - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 315
Fibre Channel IP address, and Fibre Channel subnetmask of logical switch 0. 1 Sets the Ethernet IP address, Ethernet subnetmask, Fibre Channel IP address, and Fibre Channel Subnetmask of logical switch 1. When used in command line mode, the following operands are supported: -Ipv6 Specifies IP - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 316
for switch number 1 on an enterprise-class system in interactive mode: switch:admin> ipaddrset -sw 1 Ethernet IP Address [192.168.166.148]: Ethernet Subnetmask [255.255.255.0]: Fibre Channel IP Address [none]: Fibre Channel Subnetmask [none]: Committing configuration...Done. OK. To enable DHCP - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 317
operands. Examples To display the IP address for logical switch 0: switch:admin> ipaddrshow -sw 0 Ethernet IP Address: 192.168.166.147 Ethernet Subnetmask: 255.255.255.0 Fibre Channel IP Address: 0.0.0.0 Fibre Channel Subnetmask: 0.0.0.0 See Also ipAddrSet Fabric OS Command Reference 291 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 318
default_ipv6 names are reserved for default IP filter policies. The policy name is case-insensitive and is always stored as lower case. The policy type identifies the policy as an IPv4 or IPv6 filter. You can create a maximum of eight IP filter policies. 292 Fabric OS Command Reference 53-1000599 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 319
policy, the policy existing in the defined configuration becomes active. The policy to be activated replaces the existing active policy of the same type. Activating the default IP filter policies returns the IP management interface to its default state. An IP filter policy without any rule cannot be - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 320
policies: switch:admin> ipfilter --show Name: default_ipv4, Type: ipv4, State: active Rule Source IP Protocol Dest Port Action 1 any tcp 22 permit 2 any tcp 23 permit 3 any tcp 897 permit 4 any tcp 898 permit 5 any tcp 111 permit 6 any tcp 80 permit 7 any tcp - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 321
activated policy: switch:admin> ipfilter --show Name: default_ipv4, Type: ipv4, State: active Rule Source IP Protocol Dest Port Action 1 any tcp 22 permit 2 any tcp 23 permit 3 any tcp 897 permit 4 any tcp 898 permit 5 any tcp 111 permit 6 any tcp 80 permit 7 any - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 322
ipfilter --save ex2 switch:admin> ipfilter --show Name: default_ipv4, Type: ipv4, State: active Rule Source IP Protocol Dest Port Action 1 any tcp 22 permit 2 any tcp 23 permit 3 any tcp 897 permit 4 any tcp 898 permit 5 any tcp 111 permit 6 any tcp 80 permit 7 any - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 323
iscsiCfg Configures or displays iSCSI entities. Synopsis iscsicfg create auth -u username -s CHAP_secret [-h] iscsicfg --modify auth -u --enable ddset -n ddset_name [-h] iscsicfg --disable ddset [-n ddset_name] [-h] iscsicfg --show ddset [-n ddset_name] [-v] [-h] iscsicfg --show fabric [-h] - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 324
-enabled switches and blades in the fabric. Changes do not take effect until a --commit all command is issued. Make all necessary configuration changes Displays the username and status for the specified user. If username is not specified, all users in the database are displayed. tgt iSCSI virtual - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 325
based on the login frame from the host. --addusername tgt -t target_name -u user_list [-h] Binds user user names defined in AUTH database from the specific target --clear tgt [-h] Clears the iSCSI target database from the fabric are not a part of the IQN format is supported. Multiple entities - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 326
. ddset_name is optional. fabric iSCSI-enabled switches and their operational states. The action is --show. --show fabric[-h] Displays the database iSNS client status of all iSCSI switches in the fabric. An asterisk (*) next to the switch ID denotes the local switch. initiator iSCSI Initiator - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 327
iscsiCfg 2 --commit all [-f] [-h] Commits the iSCSI configuration database to nonvolatile memory. Any modifications made to the database are not saved until an explicit --commit all is issued. If multiple switches in the fabric have uncommitted changes, this operation is rejected. The -f option - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 328
. To unbind user CHAP from a target: switch:admin> iscsicfg 80:00:43:80:a2 Number of LUN Maps: 5 FC WWN Virtual LUN(s) Physical LUN(s) 50:06:0e:80:00:43:80:a2 0 0x0000000000000000 50:06:0e:80:00:43:80:a2 1 0x0001000000000000 50:06:0e:80:00:43:80:a2 2 0x0002000000000000 50:06:0e:80:00:43:80 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 329
myddset -d mynewdd The operation completed successfully. To display the iSCSI-aware switches and their operational states (Displays switches that are capable of propagating iSCSI data base): switch:admin> iscsicfg --show fabric Switch ID Switch WWN Switch State iSNSC * 1 10:00:00:60:69:e4:20:1e - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 330
See Also To display the iSCSI initiators that attempted to log in: switch:admin> iscsicfg --show initiator Number of records found: 1 Name iqn.1991-05.com.brocade:initiator1 IP Address 172.16.14.101 switch:admin> iscsicfg --show initiator -i iqn.1991-05.com.brocade:initiator1 Initiator details - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 331
- 7 or specify 8 for all ports. Examples To run iscsichiptest: switch:admin> iscsichiptest --slot 7 -unit 1 -testtype 0 Running iscsichiptest Test Complete: iscsichiptest Pass 1 of 1 Duration 0 hr, 3 min & 12 sec (0:3:12:511). passed. See Also iscsiPathTest Fabric OS Command Reference 305 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 332
. Manage/display iscsi switch configuration parameters. Create/Delete a new ip interface/route/arp entry on the GigE port Show configured ip interfaces/routes/arp entries on the GigE Port Display the number of sessions on each iSCSI port See Also switchShow 306 Fabric OS Command Reference 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 333
transmitted on each port. The default value is 100. Examples To run iscsipathtest: switch:admin> iscsipathtest --slot 2 -path 2 -nframes 10 Running iscsipathtest Test Complete: iscsipathtest Pass 10 of 10 Duration 0 hr, 3 min & 1 sec (0:3:0:630). passed. See Also iscsiChipTest Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 334
immediate data support; specify 0 to disable or 1 to enable. -f value Specifies the first burst length value; values include 512, 1024, 2048, 4096, 8192, 16384, and 32768. --clearstats Clears port-level iSCSI statistics on the specified port. --default Resets the port to the default values - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 335
, which displays the initiator IP, TSID, and the number of connections in addition to the other port-level information. Specifies the slot number. This parameter only supports FC4-16IP blades in Brocade 48000 directors. Specifies the port number of a GbE port to be configured in the specified slot - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 336
Session details: Session Number: iSCSI Session Type: Initiator Name: Target Name: ISID: fosConfig, iscsiCfg, iscsiSessionCfg 0 0 0 0 0 0 17 2576 17 1352 1 Normal iqn.1991-05.com.microsoft:win-iscsi.lab iqn.2002-12.com.tgt:21:00:00:04:cf:5d:cf:0e 0x400001370000 310 Fabric OS Command Reference 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 337
Port Leading Connection Switch Port 1 2743 Yes 8/ge4 Security Details CHAP Username: none FC Details Number of FC targets: 1 FC Target Information Index FC WWN 1 2f:df:00:06:2b:0d:10:b9 iSCSI Operating Login Parameters: Session Level Parameter Name Self Value Peer Value Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 338
Length First Burst Length Max outstanding R2T Default time to retain Default time to wait Error recovery level Initial Abort Task Set: 0 iSCSI Clear ACA: 0 iSCSI Clear Task Set: 0 iSCSI LUN Reset: 0 iSCSI Target Reset: 0 iSCSI Task Reassign: 0 Non FCP in PDU: 0 Non FCP in Octet: 0 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 339
all slots. --showconn Displays the configuration of the connection redirection. --modifygw Specifies the IQN prefix of the target name. --showgw Displays the target name prefix. Examples To enable the connection redirection on slot 3: switch:admin> iscsiswcfg --enableconn -s 3 The operation - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 340
2 iscsiSwCfg See Also fosConfig, iscsiCfg, iscsiPortCfg 314 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 341
enabled, if applicable • QoS enabled, if applicable Connection speed is not applicable to LE_Ports or VE_Ports,. For these port types, speed displays as "sp:-------". Operands none Examples To display the ISL connections for the switch: switch:user Fabric OS Command Reference 315 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 342
only supports Brocade FC4-16IP blades in Brocade 48000 directors. -s server_ip Specifies the IP address in dotted-decimal form. Examples To set the IP address of an external iSNS server with an attached GbE port: switch:admin> isnsccfg --set 7/ge0 -s 192.168.131.124 iSNS client configuration - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 343
2 See Also To register the iSNS objects: switch:admin> isnsccfg --reregister Initiated re-register of iSNS objects with iSNS server To clear the IP address of iSNS server: switch:admin> isnsccfg --clear Cleared iSNS server configuration. none Fabric OS Command Reference 317 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 344
it is legal syntax, the ports do not exist. • If no slot number is specified, all lists except user port lists use the default slot 0. • No list type except for user port lists may specify multiple conflicting slot numbers. For instance, "1/0, 2/0, 3/0" is a valid user port list but is not valid - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 345
which user-accessible external ports within the current switch (selected during Telnet login) are tested. When specified in an item list, user ports might be specified by either the area portion of the ports Fibre Channel address or with slot/port notation. For non-blade systems, the port number on - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 346
serial port login sessions and information such as session number, login name, idle time, IP address USER TTY IDLE FROM LOGIN@ ~ 0 root0 ttyS0 1:17m - 5:13pm 1 admin0 pts/1 3.00s 192.168.130.29 6:31pm Enter Session Number to terminate (q to quit) q See Also none 320 Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 347
server role to one of the default roles available on a switch. This command also provides an option user belonging to that group to login to the switch with the permissions associated with the mapped switch role. This command supports one-to-one role mapping only. For example, you might map the "SAN - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 348
role to the switch role of "operator": switch:admin> ldapcfg --maprole SANoperator operator LDAP role SANoperator has been successfully mapped. switch:admin> ldapcfg --unmaprole SANoperator LDAP role SANoperator has been successfully unmapped. aaaConfig, userConfig 322 Fabric OS Command Reference - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 349
. Some features of the switch and the fabric to which it is connected are optional, licensed products. Without a license installed for such products, their services are not available. A license key is a string of approximately 16 upper- and lowercase letters and numbers. Case is significant. The - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 350
licenseremove licenseshow Adds license keys to switch Print license help info Displays the system license ID Removes a license key from this system Displays current license keys See Also licenseAdd, licenseIdShow, licenseRemove, licenseShow 324 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 351
Use this command to display the license ID of the system. Some features of the switch and the fabric are optional, licensed products. Without a license installed for such products, the services provided by these features are not available. This command displays the system license ID used - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 352
--reserve 5 To change the POD license method to the Dynamic method: switch:admin> licensePort -method dynamic To display the POD license assignments: switch:admin> licensePort --show 20 ports are available in this switch 1 POD license is installed 326 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 353
POD license Ports assigned to the base switch license: 0, 1, 2, 3, 4, 5, 6, 7, 15, 16 Ports assigned to the first POD license: 8, 9, 17, 18, 19 Ports assigned to the second POD license: 10, 11, 12, 13, 14 [Note: these ports cannot be activated due to an insufficient number of installed POD licenses - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 354
key, in quotation marks. This operand is required. Examples To remove a license key from the switch: switch:admin> licenseremove "bQebzbRdScRfc0iK" removing license key "bQebzbRdScRfc0iK" See Also licenseAdd, licenseHelp, licenseIdShow, licenseShow 328 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 355
keys on a switch with permanent licenses installed: switch:admin> licenseshow S9bddb9SQbTAceeC: Fabric license eezeRRySff0fSe: Remote Switch license bzbzRcbcSc0c0SY: Remote Fabric license dSeR9RcSeeTfSAq: Extended Fabric license RyeSzRScycTzfT09: Entry Fabric license RyeSzRScycUzfT0A: Fabric Watch - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 356
on the switch, including non-ISLs. An E_PORT suffix is appended to the interface number of active ISLs. If a static cost is assigned to a port, a STATIC suffix is appended to the link cost. In this case, only the current link cost displays. Use interfaceShow to display both the default and current - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 357
Cost 500 (STATIC) To delete the cost value and reset to default: switch:admin> linkcost 2/4 0 To display the change: switch:admin> linkcost 2/4 Interface2/4 Cost 1000 See Also interfaceShow, lsDbShow, topologyShow, uRouteShow, fcrRouterPortCost Fabric OS Command Reference 331 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 358
that session is left open. This command allows you to access commands that you cannot access at your current user level. Operands none Examples To log in as admin from the login user: switch:user> login login: admin Password:xxxxxx See Also logout 332 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 359
command is accepted as a synonym for logout, as is Ctrl-D at the beginning of a line. Operands none Examples To log out from an rlogin session: switch:admin> logout See Also login Fabric OS Command Reference 333 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 360
information (information about the devices in the zone) is provided for each LSAN zone. The default output displays only WWNs of the zone members. Search parameters -f, -w, and -z allow searching for LSAN zones based on fabric ID, WWN of an LSAN zone member, or LSAN zone name. "No LSAN zone found - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 361
Also To display the LSAN zones: switch:admin> lsanzoneshow Fabric ID: 4 Zone Name: lsan_fcr10_0 50:05:07:65:05:84:0b:83 50:05:07:65:05:84:09:0e 10:00:00:00:c9:2b:6a:68 21:00:00:20:37:18:22:55 Fabric ID: 5 Zone Name: lsan_fcr11_0 10:00 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 362
state database record for switches in the fabric, or one domain switch. Pointer to LSR. Number of LSRs accepted, even though they were not sufficiently spaced apart. Number of LSRs not accepted because they were not sufficiently spaced apart. Last time an LSR was ignored. Time this LSR was installed - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 363
number of the switch on the other side of the link. Port number on the local switch. Port number of the port on the other side of the link. Cost of this link. The default = 0x10053d18 lsAge = 16 reserved = 0 type = 1 options = 0x0 lsId = 1 Fabric OS Command Reference 337 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 364
2, out port = 16, rem port = LinkId = 2, out port = 17, rem port = LinkId = 2, out port = 18, rem port = LinkId = 2, out port = 19, rem port = LinkId = 2, out port = 24, rem port = LinkId = 2, out port = 25, rem port = LinkId = 2, out port = 26, rem port = LinkId = 2, out port = 27, rem port - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 365
total used Mem: 129740800 112562176 Swap: 0 0 switch:admin> memshow -m total used Mem: 123 107 Swap: 0 0 free 17178624 0 free 16 0 shared 0 buffers cached 139264 30396416 shared 0 buffers 0 cached 28 See Also supportSave Fabric OS Command Reference 339 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 366
rapidly while the test runs. For each path, the path test performs the following steps: 1. Clears port statistics and error counters. 2. Enables ports for specified self-loopback mode. 3. Configures the routing table so that when port M receives frames, the frames are routed back to the partner - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 367
periodic checks of the hardware counters. At the end of a path test, all statistics and routes are reset for the next path test. An example of progresses until the specified number of frames has been transmitted on each port. The default value for count is 1, so the total number of frames sent will - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 368
) are used. Refer to itemList for further details. If all ports in the ASIC pair are not specified, only paths between selected ports are tested. ASIC-pair 0: -ports 0-15 ASIC-pair 1: -ports 16-31 ASIC-pair 2: -ports 32-47 ASIC-pair 3: -ports 48-63 342 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 369
, 1 min & 4 sec (0:1:4:409). passed. To run a functional test on ports 0, 1, 2, and 8 using port loopback: switch:admin> minicycle -ports 0,1,2,8 -lb_mode 1 Back Plane Loop Back mode is ON. Running mini Cycle One ERR_STAT_TRUNC FDET_PERR FINISH_MSG_ERR Fabric OS Command Reference - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 370
LESSN_STATUS_ERR MBUF_STATE_ERR MBUF_STATUS_ERR NO_SEGMENT PORT_ABSENT PORT_DIED PORT_ENABLE PORT_M2M PORT_STOPPED PORT_WRONG RXQ_FRAME_ERR RXQ_RAM_PERR STATS STATS_C3FRX STATS_FRX STATS_FTX TIMEOUT XMIT Refer to the Fabric OS Message Reference for more information. itemList, portLoopbackTest 344 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 371
switch in the fabric: switch:admin> mscapabilityshow Switch WWN Capability Switch Name 10:00:00:60:69:20:15:71 0x0000008f "switch1"* 10:00:00:60:69:00:30:05 0x0000008f "switch2" Capability Bit Definitions: Bit 0: Basic Config Service Supported. Bit 1: Platform Management Service Supported - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 372
Use this command to configure the MS Access Control List (ACL). The MS allows a Storage Area Network (SAN) management application to retrieve and administer the fabric and Interconnect Elements, such as switches. This application is located at the Fibre Channel well-known address, 0xFFFFFA - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 373
list 2 Add member based on its Port/Node WWN 3 Delete member based on its Port/Node WWN select : (0..3) [1] 0 done ... msCapabilityShow, msPlatShow, msPlClearDB, msPlMgmtActivate, msPlMgmtDeactivate, msTdDisable, msTdEnable, msTdReadConfig, secPolicyShow Fabric OS Command Reference 347 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 374
, and associated node names. Operands none Examples To display the MS platform database for a fabric: switch:admin> msplatshow Platform Name: [9] "first obj" Platform Type: 5 : GATEWAY Number of Associated M.A.: 1 Associated Management Addresses: [35] "http://java.sun.com/products/plugin - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 375
Examples To display the MS platform service database control block: switch:admin> msplatshowdbcb Domain Worldwide Name Retry == 255. msPlDBCB.enabled == 1. See Also msCapabilityShow, msConfigure, msPlatShow, msPlClearDB, msPlMgmtActivate, msPlMgmtDeactivate Fabric OS Command Reference 349 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 376
" for details. This command is supported only in AD0 and AD255 contexts. Operands none Examples To clear the MS platform database: switch:admin> msplcleardb MS Platform Service is currently enabled. This will erase MS Platform Service Database in the entire fabric. Would you like to continue - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 377
reboots. Notes By default, the MS platform service is disabled. Before issuing this command, run msCapabilityShow to verify that all switches in the fabric support the MS platform service; if one switch does not support the service, the command fails. When FCS policy is enabled, this command can - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 378
This command is supported only in AD0 and AD255 contexts. Operands none Examples To deactivate the MS platform service on all switches in the fabric: switch:admin> msplmgmtdeactivate MS Platform Service is currently enabled. This will erase MS Platform Service configuration information as well - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 379
service on a local switch or an entire fabric. This change takes effect immediately and commits to the configuration database for all affected switches (including attached switches) to support request node identification data (RNID) extended link service (ELS). When FCS policy is enabled, and this - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 380
mstdenable ["ALL"] Description Use this command to enable the MS topology discovery service on the local switch or throughout the fabric. The change takes effect immediately and commits to the configuration database for all affected switches. The change is persistent across power cycles and - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 381
Operands none Examples To display the status of the topology discovery service: switch:admin> mstdreadconfig *MS Topology Discovery is enabled. See Also msCapabilityShow, msConfigure, msPlMgmtActivate, msPlMgmtDeactivate, msTdDisable, msTdEnable Fabric OS Command Reference 355 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 382
CP/switch (or console/serial port) used to log in. • The IP address of the current login session for Telnet or the name of the current console port or the serial port ( switch:admin> myid Current Switch: switch Session Detail: switch (123.123.123.123) Active Redundant See Also version 356 Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 383
Domain Domain number of remote switch. Remote Port E_Port (interface) on remote switch. State switches directly connected to the local switch: switch:user> nbrstateshow 2/0 Local Domain ID: 1 Local Port Domain Remote Port State 16 2 48 NB_ST_FULL See Also interfaceShow Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 384
number of the port to display, followed by a slash (/). portnumber Specify the port number to display, relative to its slot for bladed systems. Use switchShow to list valid ports. This operand is optional; if omitted, FSPF statistics are reset. Examples To display the counters on a port: switch - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 385
To reset the counters on a port: switch:admin> nbrstatsclear 1/0 To verify the changes: switch:admin> interfaceshow 1/0 idbP = 0x10050a38 Interface 0 data structure: nghbP ifNo masterPort defaultCost cost = 0x1004ce68 = 0 = 0 (self) = 500 = 500 (output truncated) See Also interfaceShow, - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 386
matching the alias "a320": switch:user> nodefind a320 Local: Type Pid COS PortName NodeName SCR NL 0314d9; 3;22:00:00:04:cf:5d:dc:2d;20:00:00:04:cf:5d:dc:2d; 0 FC4s: FCP [SEAGATE ST318452FC 0001] Fabric Port Name: 20:14:00:60:69:80:04:79 Permanent Port Name: 22:00:00:04 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 387
Other AD: No Aliases: To display all the device information matching the PID "0x020eef": switch:user> nodefind 0x020eef Remote: Type Pid COS PortName NodeName NL 020eef; 3;20:00:00:e0:8b:01:ce:d3;20:00:00:e0:8b:01:ce:d3; Fabric Port Name: 20:0e:00:60:69:51:0b:ba Permanent - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 388
to the Nx_Port, using FLOGI to log in to the switch. • Virtual - Contrived device by the switch. • NPV - Device connected to the Nx_Port, using FDISC to log in to the switch. • iSCSI - Device connected to the iSCSI port. The second part indicates the role of the device. Currently, four roles are - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 389
Server has 6 entries } To display local NS information with aliases with the -r option: switch:admin> nsaliasshow -r { Type Pid COS PortName NodeName SCR N 021200; 2,3;10:00:00:60:69:00:03:19;30:00:00:60:69:00:03:19; 3 FC4s: FCIP Fabric Port Name: 20:02:00:60:69:01:44:22 Permanent - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 390
has 6 entries } To display local NS information with aliases with the -r and -t options: switch:admin> nsaliasshow -r -t { Type Pid COS PortName NodeName SCR N 021200; 2,3;10:00:00:60:69:00:03:19;30:00:00:60:69:00:03:19; 3 FC4s: FCIP Fabric Port Name: 20:02:00:60:69:01:44:22 Permanent - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 391
IP type device Other FC-PH types are displayed in the format "x ports supporting FC4 code," where x is the number of ports of a type and code is the FC-PH type code. Examples To display all devices in the fabric, followed by all type 8 (SCSI-FCP) devices and all type 5 (SCSI-FCIP) devices: switch - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 392
for that domain number. For each device found in the devices list, the following information is displayed: Type U for unknown, N for N_Port, NL for NL_Port. Pid The 24-bit Fibre Channel address. COS A list of classes of service supported by the device. PortName The device's port World Wide - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 393
;10:00:00:60:69:00:ab:ba; FC4s: FCIP PortSymb: [28] "SEAGATE ST318452FC 0001" Fabric Port Name: 20:02:00:60:69:00:68:19 Permanent Port Name: 10:00:00:60:69:00:ab:ba Switch entry for 4 state rev owner known v320 0xfffc01 Device list: count 0 No entry is found! To - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 394
to display NS information for all switches in the fabric. Each line of output displays the following information: Type U for unknown, N for N_Port, NL for NL_Port. PID 24-bit Fibre Channel address. COS List of classes of service supported by device. PortName Device port World Wide Name (WWN - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 395
Of the two device type parts, the first part indicates the origination of the switch:admin> nsshow { Type Pid COS PortName NodeName TTL(sec) N 010100; 3;21:00:00:e0:8b:13:08:10;20:00:00:e0:8b:13:08:10; na FC4s: FCP NodeSymb: [41] "QLA2340 FW:v3.03.06 DVR:v9.0.0.2 (w32 IP)" Fabric Port - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 396
name server information with "-r" and "-t" options. switch:admin> nsshow -r -t { Type Pid COS PortName NodeName SCR N 010100; 3;21:00:00:e0:8b:13:08:10;20:00:00:e0:8b:13:08:10; 1 FC4s: FCP NodeSymb: [41] "QLA2340 FW:v3.03.06 DVR:v9.0.0.2 (w32 IP)" Fabric Port Name: 20:01:00:05:1e:34 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 397
unknown, N for N_Port, NL for NL_Port. Pid The 24-bit Fibre Channel address. COS A list of classes of service supported by the device. PortName The device's port World Wide Name (WWN). NodeName The device's node WWN. Permanent Port Name The physical N_Port or NL_Port WWN. DeviceType The - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 398
about all the online devices zoned with the given device: switch:admin> nszonemember 0x0416e2 3 local zoned members: Type Pid COS PortName NodeName SCR NL 041901; 2,3;10:00:00:00:c9:26:0e:ae;20:00:00:00:c9:26:0e:ae; 3 Fabric Port Name: 20:09:00:60:69:50:06:78 Permanent - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 399
Aliases: hds9200_6p4 hds9200_6p4 Port: 14 Pid: 0xb00e00 Aliases: dl360_130251a dl360_130251a Zoned Members: 2 devices Pid: 0xb00e00 Aliases: dl360_130251a dl360_130251a Pid: 0xba1ae4 Aliases: trimm100a_2 To display all the unzoned devices in the fabric: switch:admin> nszonemember -u Pid - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 400
to other switches in the fabric, the switches must be configured to accept the password database with the fddCfg command. The password database is distributed manually with the distribute command. If RADIUS authentication is enabled, password change is blocked for users changing their own - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 401
error messages. Refer to the Fabric OS Message Reference for more diagnostic information. RADIUS enabled error Password change disallowed, RADIUS authentication is enabled. Password error Password length, strength, or history policy not met. "user" is not a valid user name You have not specified - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 402
. You must wait longer to change your password. You cannot change the password before the minimum aging period expires. Password contains invalid characters. The password you entered contains invalid characters. See Also login, logout, passwdCfg 376 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 403
password expiration policy is enforced across all user accounts except the root and factory accounts. Account Lockout Policy The account lockout policy disables a user account when the user exceeds a configurable number state. The account lockout Fabric OS Command Reference 377 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 404
--showall Displays all the password configuration parameters. --set Configures a specified password policy. The following arguments are supported: -lowercase value Specifies the minimum number of lowercase alphabetic characters that must occur in the password. The default value is 0. The maximum - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 405
is displayed. The valid range for -warning is 0 to 999. The default value to 0. -lockoutthreshold value Specifies the number of times a user can specify an incorrect password during login before the account is locked. The number of failed login attempts is counted from the last successful login - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 406
already enabled and sets the config parameter "passwdcfg.adminlockout" to 0. By default, admin lockout policy is disabled. --setdefault Resets all password policies to their default values. --help Displays command usage. Examples To display the current password configuration parameters: switch - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 407
The -history value must be between 1 and 24. minpasswordage value out of range The -minpasswordage value be between 0 and 999. invalid password expiration specification The -minpasswordage value or 40. sequence value out of range The -sequence value must be between 1 and 40. passwd, userConfig Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 408
along the path is busy: for instance, if a switch is performing a warm recovery or if a switch along the path does not support this feature. If the advanced performance tuning (APT) policy in effect on the intermediate switches is not a port-based policy, subsequent data streams might not take the - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 409
per second received or transmitted; reports for multiple time periods, displayed in parentheses. Words Total number of 4-byte Fibre Channel words. Frames Total number of frames. Errors Total number of errors that might cause a frame not to be received correctly. This includes CRC errors - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 410
to the portions of the path described by domains, not to the part described by output ports or areas. Switches running pre-v5.2 firmware cannot use port numbers greater than 256 as a destination port on a remote switch. Note The execution of this command is subject to Admin Domain restrictions - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 411
time allowed to wait for the response; default is 10 seconds. To display basic path information to a specific domain, using the command line (non-interactive mode): switch:admin> pathinfo 91 Target port is Embedded Hop In Port Domain ID (Name) Out Port BW Cost 0 E 9 (web226) 2 1G 1000 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 412
2 pathInfo Words Frames Errors 240434036 20025929 - 2294316 54999 4 2119951 162338 - Hop In Port Domain ID (Name) Out Port BW Cost 2 14 8 (web228) E - - (output truncated) See Also portStatsShow, switchShow 2121767 56710 0 386 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 413
from the latest panic dump file available on the switch. If a panic dump file is specified as an the following optional operand: panic_dump_file Specify the full path name of a panic dump file. Tue Dec 3 16:06:11 UTC 2002 Kernel= 2.4.19 Fabric OS= v4.1.0_j_dist_1103 Made on= Tue Dec 3 19:07: - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 414
number of CRC errors for both directions. Adding a monitor on port 1, specifying 0x010100 as SID and 0X050200 as the DID has a similar effect, except the RX and TX counts are interchanged. If ISL monitoring is enabled, end-to-end cannot be 0x000000. 388 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 415
blade 1 port 2: switch:admin> perfaddeemonitor 1/2 "0x050200" "0x1182ef" End-to-End monitor number 0 added. See Also perfAddIPMonitor, perfAddReadMonitor, perfAddRWMonitor, perfAddSCSIMonitor, perfAddUserMonitor, perfAddWriteMonitor, perfDelEEMonitor, perfMonitorClear, perfMonitorShow Fabric OS - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 416
. The default alias is "IP Frame". Examples To add an IP monitor to a port: switch:admin> perfaddipmonitor 1/4 IP_MONITOR IP traffic frame monitor #0 added See Also perfAddEEMonitor, perfAddReadMonitor, perfAddRWMonitor, perfAddSCSIMonitor, perfAddUserMonitor, perfAddWriteMonitor 390 Fabric OS - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 417
command. Synopsis perfaddreadmonitor [slotnumber/]portnumber [alias] Description Use this command to create a filter-based monitor that counts the number of SCSI FCP Read commands in Fibre Channel frames. Only frames transmitted are counted. Execution of this command displays a numeric key that - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 418
. Synopsis perfaddrwmonitor [slotnumber/]portnumber [alias] Description Use this command to create a filter-based monitor that counts the number of SCSI FCP Read and Write commands in Fibre Channel frames. Only frames transmitted are counted. Execution of this command displays a numeric key - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 419
to create a filter-based monitor that counts the number of SCSI traffic frames. port: switch:admin> perfaddscsimonitor 2/4 "SCSI FR" SCSI traffic frame monitor #0 added See Also perfAddEEMonitor, perfAddIPMonitor, perfAddReadMonitor, perfAddRWMonitor, perfAddUserMonitor, perfAddWriteMonitor Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 420
command for a listing of valid keys and user-defined aliases. Notes This command requires an Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. The execution of this command is subject to - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 421
. This operand is optional. By default, the alias is an empty string. Examples To add a filter-based monitor for all Extended Link Service requests (R_CTL=0x22 and TYPE=0x01) to a port: switch:admin> perfaddusermonitor 1/4 "4, 0xff, 0x22; 12, 0xff, 0x01" User monitor #0 added As a special case - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 422
command. Synopsis perfaddwritemonitor [slotnumber/]portnumber [alias] Description Use this command to create a filter-based monitor that counts the number of SCSI FCP write commands in Fibre Channel frames. Only frames transmitted are counted. Execution of this command displays a numeric key that - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 423
the previously saved end-to-end and filter configuration settings of performance monitoring from nonvolatile memory. Notes This command requires an Advanced Performance Monitoring license. This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE ports. The - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 424
nonvolatile memory: switch:admin> perfcfgrestore This will overwrite current Performance Monitoring settings in RAM. Do you want to continue? (yes, y, no, n): [no] y Please wait ... Performance monitoring configuration restored from FLASH. See Also perfCfgClear, perfCfgSave 398 Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 425
configuration to firmware: switch:admin> perfcfgsave This will overwrite previously saved Performance Monitoring settings in FLASH. Do you want to continue? (yes, y, no, n): [no] y Please wait ... Performance monitoring configuration saved in FLASH. See Also perfCfgClear, perfCfgRestore Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 426
" for details. This command is not supported on all platforms. Refer to the Fabric OS Administrator's Guide for specific hardware support. Operands This command has the following operands: slotnumber For bladed systems only, specifies the slot number of the port on which the monitor is to be - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 427
an end-to-end monitor on a port, or all such monitors: switch:admin> perfdeleemonitor 7/2 5 End-to-End monitor number 5 deleted switch:admin> perfdeleemonitor 7/2 This will remove ALL EE monitors on port 2, continue? (yes, y, no, n): [no] y See Also perfAddEEMonitor, perfMonitorShow Fabric OS - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 428
monitors from the port: switch:admin> perfdelfiltermonitor 2/3 4 The specified filter-based monitor is deleted. switch:admin> perfdelfiltermonitor 2/3 This will remove ALL monitors on port 19, continue? (yes, y, no, n): [no] y See Also perfAddUserMonitor, perfMonitorShow 402 Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 429
an end-to-end monitor Delete filter-based monitor Clear end-to-end/filter-based/ISL monitors Show end-to-end/filter-based/ISL monitors Set overall mask for end-t-end monitors Get ALPA CRC count by port and ALPA Show the current end-to-end mask Install Top Talker monitor See Also none Fabric OS - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 430
' counters on port 2, continue? (yes, y, no, n): [no] y To clear statistics counters for a filter-based monitor: switch:admin> perfmonitorclear --class FLT 1/2 4 Filter-based monitor number 4 counters are cleared switch:admin> perfmonitorclear --class FLT 1/2 404 Fabric OS Command Reference - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 431
monitor: switch:admin> perfmonitorclear --class ISL 1 This will clear ISL monitor on port 1, continue? (yes, y, no, n): [no] y See Also perfAddEEMonitor, perfAddIPMonitor, perfAddReadMonitor, perfAddRWMonitor, perfAddSCSIMonitor, perfAddUserMonitor, perfAddWriteMonitor, perfMonitorShow Fabric OS - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 432
[slotnumber/]portnumber [interval] Description Use this command to display performance monitors on a port. Monitor classes include end-to-end monitors (EE), filter-based monitors (FLT), and Inter-Switch Link monitors (ISL). ISL monitors are automatically activated on E_Ports (not including trunk - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 433
0x1182ef TELNET 0x0000000000000000 0x0000000000000000 N/A To display end-to-end monitors on a port at an interval of every 5seconds: switch:admin> perfmonitorshow --class EE 8 5 Showing EE monitors 8, 5: Tx/Rx are # of bytes 0 1 2 3 4 5 6 7 Fabric OS Command Reference 407 53-1000599 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 434
26k 204 717 717 717 513 204 To display ISL monitor information on a port: switch:admin> perfmonitorshow --class ISL 1/1 Total transmit count for this ISL: 1462326 Number of destination domains monitored: 3 Number of ports in this ISL: 2 Domain 97: 110379 Domain 98: 13965 Domain 99 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 435
this command to set the mask for an end-to-end (EE) performance monitor. This command allows selecting the Fibre Channel frames for which to collect performance statistics. When setting the EE mask on a port, all existing EE monitors on that port are deleted. This command controls all three address - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 436
mask for end-to-end monitors on a port: switch:admin> perfsetporteemask 1/6 "00: port will cause ALL EE monitors on this port to be deleted. continue? (yes, y, no, n): [no] y The EE mask on port 6 is set and EE Monitors on this port are deleted See Also perfAddEEMonitor, perfShowPortEEMask 410 Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 437
" for details. This command is not supported on all platforms. Refer to the Fabric OS Administrator's Guide for specific hardware support. Operands This command has the following operands: slotnumber For bladed systems only, specifies the slot number of the port to be displayed, followed by - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 438
Examples To display the end-to-end mask on a port: switch:admin> perfshowporteemask 2/4 The EE mask onport 20 is set by application NONE TxSID Domain: on TxSID Area: on TxSID ALPA: on TxDID Domain: on TxDID Area: on TxDID ALPA: on RxSID Domain: on RxSID Area: on 412 Fabric OS Command Reference - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 439
perfShowPortEEMask 2 RxSID ALPA: on RxDID Domain: on RxDID Area: on RxDID ALPA: on See Also perfAddEEMonitor, perfDelEEMonitor, perfSetPortEEMask Fabric OS Command Reference 413 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 440
the Brocade 7500. Top Talker supports two modes, Port Mode and Fabric Mode: • In Port Mode, Top Talker is installed on an F_Port to measure the traffic originating from the F_Port and flowing to different destinations. The output displays the data in a sorted order based on the data rate of each - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 441
an existing Top Talker monitor on a specified F_Port. Fabric Mode Top Talker commands: --add fabricmode Installs the Top Talker monitor on all switches in the fabric.When a new switch joins the fabric, this command needs to be run again on the switch. The TT config information is not propagated - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 442
6.830 0xa909d5 0xa05200 6.772 To delete the Fabric Mode Top Talker: Switch:admin> perfttmon --del fabricmode To add the Fabric Mode Top Talker: Switch:admin> perfttmon --add fabricmode To display to Fabric Mode Top Talker output: Switch:admin> perfttmon --show dom 101 pid Src_PID - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 443
is displayed: switch:admin> pkicreate Pki objects already exist. If you want to regenerate new objects, remove current objects by running pkiRemove command with security disabled. WARNING: Recertification is required with new pki objects before security can be enabled pkiRemove, pkiShow Fabric OS - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 444
the security functionality of this fibre channel switch. If you want secure mode enabled, you will need to get the switch certificate again. About to remove Pki objects. ARE YOU SURE (yes, y, no, n): [no] y All PKI objects removed. See Also pkiCreate, pkiShow 418 Fabric OS Command Reference 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 445
-phrase, CSR, root certificate, and switch certificate. Operands none Examples To view PKI objects: switch:admin> pkishow Passphrase : Exist Private Key : Exist CSR : Exist Certificate : Empty Root Certificate: Exist See Also pkiCreate, pkiRemove Fabric OS Command Reference 419 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 446
algorithm. The default is SHA-1. Algorithms include: Secure hash algorithm. Message digest 5. Advanced encryption standard. Valid only with IPSec. Specifies the perfect forward secrecy. This operand is valid only with IKE policies. Values are on (default) or off. 420 Fabric OS Command Reference - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 447
to 250000000 or 0. The default is 28800. Examples To create a new policy: switch:admin> policy --create Life (seconds): 28800 IKE Policy 29 Authentication Algorithm: SHA-1 Encryption: AES-128 Perfect Forward Secrecy: on Diffie-Hellman Group: 1 SA Life (seconds): 28800 Operation Succeeded Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 448
Algorithm: SHA-1 Encryption: AES-128 Perfect Forward Secrecy: 0 Diffie-Hellman Group: 1 SA Life (seconds): 28800 To delete a policy: switch:admin> policy ike --delete 10 The policy has been successfully deleted. See Also portCfg, portCfgShow, portShow 422 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 449
Specify the port number to display, relative to its slot for bladed systems. Use switchShow to list valid ports. Examples To display the AL_PAs of a port: switch:user> portalpashow 4/14 AL_PA type AL_PA 0xe2 public 0xe4 type public AL_PA type See Also switchShow Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 450
the port at full bandwidth (depending on the port configuration). If the number of Buffer Usage is less than the number of Needed Buffers, the port is operating in the buffer limited mode. Link Distance For L0 (not in long distance mode), the command displays the fixed distance based on port speed - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 451
by a slash (/). portnumber Specifies the number of a port associated with the port group, relative to its slot for bladed systems. Use switchShow for a list of valid ports. Examples To display the port buffer information for a port: switch:admin> portbuffershow 17 User Port Lx Max/Resv Buffer - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 452
and 7/39 are shared ports and 7/31 is primary. In this case portCamShow displays the following output: switch:user> portcamshow 7/39 Area SID used DID used SID entries DID entries 207 3 1 03b380 03cf80 034100 03cf00 SID free, DID free: (2044, 1020) 426 Fabric OS Command Reference - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 453
) To display the filter CAM utilization for a single port on a switch: switch:user> portcamshow 3/2 Area SID used DID used SID entries DID entries 34 3 1 350400 2b2200 2b1200 220400 SID Free, DID Free: (61, 511) See Also switchShow Fabric OS Command Reference 427 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 454
, modify, and delete Fibre Channel over IP (FCIP) tunnels. - Delete, reset, and modify QoS mappings on an existing tunnel. - Create or modify a tunnel with VLAN tagging and Class of Service (CoS). • Configure IP interfaces on the GbE port. • Configure static routes on the IP interface. • Manage - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 455
ARP table. Only dynamic entries can be flushed, static entries cannot be cleared. fciptunnel Creates Fibre Channel over IP (FCIP) tunnels. You can configure up to a maximum of eight FCIP tunnels per GbE port. This feature requires an FCIP license. The syntax for portCfg fciptunnel is as follows - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 456
with -ike and -ipsec. NOTE: Only a single IPSec-enabled tunnel can be configured on a port. No other tunnels (IPSec or otherwise) can be configured on the same port. Jumbo frames are not supported on secure tunnels. Only a single route is supported on an interface with a secure tunnel. -v vlan_id - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 457
to 16; default is 8. If tape pipelining is enabled, the default value is calculated based on the minimum enable (1) selective acknowledgement (SACK) on the existing tunnel. -t 0|1 Disable (0) or enable (1) tape pipelining on the existing tunnel (requires fast write to be turned on as well). Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 458
qosmap: tunnel_id Specifies the tunnel_id. Range is 0-7. -default Resets/sets VC QoS map to default values. -delete Deletes associated QoS map configuration file. Delete QoS mappings before downgrading to pre-v6.0.0 firmware versions that do not support QoS mapping. It removes the file from - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 459
IPv4 address of the virtual port. iproute Defines static IP routes on a GbE port. After defining the IP interface of the remote switch, you can define destination routes on an interface. A maximum of 32 routes per GbE port are supported. IPv6 addresses are supported on platforms running v6.0.0 or - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 460
to the mirror port. Port mirroring can aid in troubleshooting common FC end-to-end communication problems. The command prompts for confirmation that the specified port be enabled as a mirror port. Once a port is configured as a mirror port, the port can only be used as part of a mirror connection - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 461
also be used to list all ports configured for FC fastwrite. This feature requires a Brocade license. The syntax for portcfg fastwrite is as follows: portcfg fastwrite [slot/]port mode Valid modes for fastwrite are: Enables FC fastwrite on the specified port. Disables FC fastwrite on the specified - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 462
when a TIN/TIR exchange occurs as part of a channel recovery operation during tape emulation. 1 is enabled, O is disabled. -l 1|0 Enables or disables Device Level Acknowledgement emulation. This feature is applicable to both FICON Disk and Tape configurations. The feature removes one network round - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 463
|--oxidBase value Defines the base value of an entry pool of 256 OXIDs supplied to emulation-generated exchanges. It should fall outside the range used by FICO channels and devices to avoid conflicts. The default value is 0x1000. The range is 0x0000 to 0xF000. Fabric OS Command Reference 437 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 464
Deletes an existing FTRACE configuration. The following optional feature arguments are supported with the cfg and del options. These configurations are persistent. -a 1|0 Enables or disables ACO. 1 is enabled, O is disabled. The default value is 0. -b Specifies the number of buffers. The range - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 465
create a static IP route using IPv4: switch:admin> portcfg iproute ge0 create 172.16.123.231.255.255.0.0 192.168.255.25 1 Operation Succeeded To create a static IP route using IPv6: switch:admin> portcfg iproute 8/ge0 create 3000:4444:800::3456/64 1080::8:800:200C:1234 Fabric OS Command Reference - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 466
and FTRACE enabled on port ge0/tunnel 3: switch:admin> portcfg ftrace ge0 3 cfg -a 0 -e 1 -p 5 -s 00000003 -t ffffffff To delete the FTRACE on the same port/tunnel: switch:admin> portcfg ftrace ge0 3 del See Also portCfgShow, portCmd, portShow, switchShow, configure, fastWriteCfg 440 Fabric OS - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 467
to 0x13. A value of 0 sets the default AL_PA to 0x0. This operand is required. Examples To configure a port with AL_PA 0x0 (default): switch:admin> portcfgalpa 1/3 0 To configure a port with AL_PA 0x13: switch:admin> portcfgalpa 1/3 1 See Also portCfgShow Fabric OS Command Reference 441 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 468
credit recoery configuration on the specified port. --help Displays command usage. Examples To enable credit recovery on a port: switch:admin> portcfgcreditrecovery --enable 3/15 To disable credit recovery on a port: portcfgcreditrecovery --disable 3/15 See Also portCfgShow 442 Fabric OS - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 469
followed by a slash (/). port Specify the number of the port to be reset to default, relative to its slot for bladed systems. Use switchShow to list valid ports. Examples To reset a port to factory defaults: switch:admin> portcfgdefault 1/3 To reset a GbE port to factory defaults: switch:admin - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 470
the slot number of the port to be configured, followed by a slash (/). port Specify the number of the port to be configured, relative to its slot for bladed systems. Use switchShow to display a list of valid ports. mode Specify 1 to enable the port as an E_Port. This is the default port state - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 471
values are what the edge switch specifies in the ELP request. If the state is "Not OK", the R_A_TOV and E_D_TOV display "Not Applicable". By default, all EX_Ports are auto-ELP enabled. If the Fabric Parameter attribute value is "User configured", the port ID format R_A_TOV and E_D_TOV values - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 472
displays the current port configuration. -a admin Enables or disables the specified port as an EX_Port. Valid values are 1 (enable as EX_Port), 2 (disable as EX_Port and enable as non-EX_Port). portCfgDefault may also be used to disable EX_Ports. -f fabricid Specifies the fabric ID. Valid values - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 473
-a 1 -f 4 To disable fabric parameter negotiation on port 2/0 of an EX_Port: switch:admin> portcfgexport 2/0 -t 2 To enable IDID on port 2: switch:admin>portcfgexport 2 -i 1 To display the configuration on port 2: switch:admin> portcfgexport 2 Port 2 info Admin: enabled State: NOT OK Pid - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 474
designation from the port. A value of 0 is the default port state. Mode must be preceded by a comma. This operand is required. Examples To configure port as a locked G_Port: switch:admin> portcfggport 1/3, 1 See Also configure, portCfgLPort, portShow, switchShow 448 Fabric OS Command Reference - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 475
enabling ISL R_RDY mode, ensure that all fabric-wide parameters are consistent for every switch in the fabric. Use configshow fabric.ops to view a complete listing of fabric operating mode parameters on the switch. The following E_Port configurations are not applicable to a port configured for - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 476
2 portCfgISLMode To disable ISL R_RDY mode on a port: switch:admin> portcfgislmode 1/3, 0 See Also configure, portCfgLongDistance, portCfgShow 450 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 477
mode due to a lack of frame buffer credits. The number of credits reserved for a port depends on the switch model and on the extended fabric mode for which it is configured. Not all distance modes are supported by all platforms. For example, the FC10-6 only supports LO and LS up to 120 km at 10 Gbps - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 478
configured based on the actual link distance. Up to a total of 1452 full-size frame buffers are reserved depending on the distance measured during E_Port initialization. Fabric OS v6.0 or later supports buffers required for the port. Examples To configure a switch port 63 to support a 100 km link - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 479
: 0 Loss_of_sig: 9 Protocol_err: 0 Invalid_word: 0 Invalid_crc: 0 Delim_err: 0 Address_err: 0 Lr_in: 0 Lr_out: 0 Ols_in: 0 Ols_out: 0 Fbsy: 0 See Also configure, portCfgISLMode, portCfgTrunkPort, portCfgShow, portShow, switchShow Fabric OS Command Reference 453 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 480
command to designate a port as an L_Port, and to configure its behavior. When a port is designated as an L_Port, the switch attempts to initialize that port as a fabric L_Port (FL_Port). The switch will never attempt a point-to-point (F_Port) initialization on the port. By default the L_Port will be - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 481
the L_Port conditions: switch:admin> portcfglport [output from other slots suppressed] Ports of Slot 4 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Locked L_Port ON ON Private L_Port ON Locked Loop HD Loop Fairness See Also configure, portShow, switchShow Fabric OS Command Reference - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 482
port Specify a port number to be configured, relative to its slot for bladed systems. Use switchShow to display a list of valid ports. mode Specify 1 to enable and 0 to disable the NPIV function. Examples To enable NPIV functionality on a port: switch:admin> portcfgnpivport 1/3 1 456 Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 483
ON QOS E_Port EX Port Mirror Port Rate Limit Credit Recovery where AN:AutoNegotiate, ..:OFF, ??:INVALID. LM:L0.5 To disable NPIV functionality on a port: switch:admin> portcfgnpivport 1/3 0 See Also configure, portCfgDefault, portCfgShow Fabric OS Command Reference 457 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 484
if it is connected to an enterprise fabric switch that supports NPIV. Notes NPIV capability should be enabled on the ports connected to the Access Gateway. Use portcfgnpivport to enable NPIV capability on the specific port. By default, NPIV is enabled on Goldeneye. The execution of this command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 485
when executed on a a persistently disabled port. The persistent switch disable or enable configuration does not alter the persistent disable or enable configurations of the ports within the switch. Because the default state of the port is persistently enabled, the persistent disable state is cleared - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 486
, or switchDisable command. The persistent switch disable or enable configuration does not alter the persistent disable or enable configurations of the ports within the switch. Notes If this port is connected to another switch, then the Fabric may reconfigure. If this port is connected to one or - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 487
portCfgPersistentEnable 2 See Also ficonCupSet, ficonCupShow, portDisable, portEnable, portCfgPersistentDisable, portCfgShow, portShow, switchShow Fabric OS Command Reference 461 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 488
for all ports. --default Applies the default QoS configuration to the specified ports. QoS is enabled by best effort based on availability of buffers. --disable Disables QoS configuration on the specified ports. --enable Enables QoS configuration on the specified ports. --resetratelimit Turns - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 489
the ingress rate limit on a port to 2 Gbps: switch:admin> portcfgqos --setratelimit 3/15 2000 To set the default QoS configuration on a port: switch:admin> portcfgqos --default 3/15 See Also portCfg, portCmd, portShow, switchShow, configure : PortCfgQos 2 Fabric OS Command Reference 463 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 490
to display specific FCIP parameters configured for a gigabit Ethernet port, such as the following: • Address resolution protocol (ARP) entries • IP interfaces on the GbE port • Static routes on the IP interfaces • Fibre Channel over IP (FCIP) tunnel configuration settings - IKE and IPSec policy - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 491
ON when Quality of Service (QoS) is enabled on the port. Displays (..) or OFF when QoS is disabled. By default, QoS is enabled by best effort based on availability of buffers. This value is set by the portCfgQos command. EX_port. Displays ON when the port is configured as an EX_Port. Otherwise - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 492
Availability" for details. Operands This command supports the following port options: slot For bladed systems only, specifies the slot number of the port to be configured, followed by a slash (/). [ge]port Specifies the number of the port to be configured, relative to its slot for bladed - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 493
ON ON ON ON ON ON ON ON ON Ports of Slot 2 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Speed AN ON ON ON ON ON ON ON ON ON ON ON ON To display the configuration settings for a port with Access Gateway enabled: SW4016_5311:admin> portcfgshow Ports of Slot 0 0 1 2 3 4 5 6 7 8 9 10 11 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 494
2 portCfgShow To display the configuration settings for a single port: switch:admin> portcfgshow 2/16 Area Number: 144 Speed Level: AUTO AL_PA Offset 13: OFF Trunk Port ON Long Distance OFF VC Link Init OFF Locked L_Port OFF Locked G_Port OFF Disabled E_Port OFF ISL R_RDY Mode - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 495
7 31 0 11 47 4 15 63 0 Vlantag configuration Display of VLAN tagging on a GbE port. Refer to the portCfg help page for an explanation of the displayed parameters. switch: admin> portcfgshow vlantag 8/ge0 Port: 8/ge0 IpIfAddress VlanId L2 CoS Dest IP Address Flags 192.168.10.1 100 7 192 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 496
a specified speed. This command disables and then re-enables the port, so that it comes up with the new speed setting. The configuration is saved in nonvolatile memory and is persistent across switch reboots or power cycles. Notes This configuration cannot be set on VE/VEX_Ports. Use portShow to - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 497
[,] mode Description Use this command to enable or disable trunking on a port. Use switchCfgTrunk to enable or disable trunking on all ports of a switch. When the command is executed to update the trunking configuration, the port to which the configuration applies is disabled and subsequently re - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 498
negotiated values are what the edge switch specifies in the ELP request. If the state is "Not OK", R_A_TOV and E_D_TOV display "Not Applicable". By default, all VEX_Ports are auto-ELP enabled. If the Fabric Parameter attribute value is "User configured", port ID format, R_A_TOV, and E_D_TOV display - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 499
interoperability modes with the interopMode command. Examples To display the VEX_Port configuration of port 2/16: switch:admin> portcfgvexport 2/16 Port 2/16 Admin: State: Pid format: Edge Fabric ID: Front Domain ID: Front WWN: Principal Switch: info enabled OK core(N) 16 160 50:06:06:9e:20:9f - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 500
E_D_TOV: 2000(N) Edge fabric's primary wwn: N/A Edge fabric's version stamp: N/A To set the fabric ID of port 2/21 to 5 and the port ID format to core: switch:admin> portcfgvexport 2/21 -f 5 -p 1 To configure port 2/20 as a VEX_Port and set the fabric ID to 4: switch:admin> portcfgvexport 2/20 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 501
is optional. -p port Specifies the TCP port number for the listener end-point. This operand is optional. -q diffserv Specifies the DSCP (DiffServ Code Point) marking used for the TCP connection. This operand accepts values between 0 and 63 (inclusive). The default value is 0. Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 502
may not be accurate. --ping Pings a destination IP address from one of the source IP interfaces on the GbE port. Valid arguments include: -s src_ip Specifies the source IP address that originates the ping request. IPv6 addresses are supported. 476 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 503
dst_ip Specifies the destination IP address to which to target the ping request. IPv6 addresses are supported. -n num_requests Specifies the number of ping requests. Valid values are 1 to 255. The default is 4. This operand is optional. -q service_type Specifies the type of service in the ping - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 504
Specifies Class of Service/Priority, as defined by IEEE 802.1p. Values must be in the range 0 to 7. The default is 0. This operand is optional. with the -v option. Examples To verify if packets can be sent to the destination IP address with maximum wait_time specified: switch:admin> portcmd --ping - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 505
level to be set for port modules; valid values are 1 to 5. vbs_lvl Specify the verbose level to be set for port modules; valid values are 1 to 5. Examples To set debug level and verbose level of port modules: switch:admin> portdebug 3 4 See Also dbgShow Fabric OS Command Reference 479 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 506
Specify a port number to be disabled, relative to its slot for bladed systems. Use switchShow to display a list of valid ports. Examples To disable a port: switch:admin> portdisable 2/4 See Also portCfgPersistentDisable, portCfgPersistentEnable, portEnable, portShow, switchShow 480 Fabric OS - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 507
(/). port Specify a port number to be enabled, relative to its slot for bladed systems. Use switchShow to display a list of valid ports. Examples To enable a port: switch:admin> portenable 2/4 See Also portCfgPersistentDisable, portCfgPersistentEnable, portDisable, portShow, switchShow Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 508
Frames with bad end-of-frame delimiters counters for ports on a switch: switch:admin> 0 0 0 0 0 2 0 0 29: 0 0 - 0 0 0 0 - 0 - - - - 30: 0 0 - 0 0 0 0 - 0 - - - - 31: 0 0 - 0 0 0 0 - 0 - - - - (output truncated) See Also portShow, portStatsShow 482 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 509
port, whether the port is active, and the port type. Operands none Examples To display the port status for all ports in the switch: switch:user> portflagsshow Slot Port No_Light PRESENT LED (output truncated) See Also portShow, switchShow Fabric OS Command Reference 483 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 510
the command has finished and exited. You can enable the current switch (using the switchEnable command) to set the number of times to perform this test. The default value is 10. -ports itemlist Specify a list of user ports on which to run the test. If omitted, all the active ports in the switch - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 511
log events related to that activity. If the port log is disabled, portLogClear enables it. The port log is disabled automatically when certain errors occur clear the port log: switch:admin> portlogclear switch:admin> portlogshow port log is empty See Also portLogDump, portLogShow Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 512
"Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands none Examples To display the current port log configuration: switch:admin> portlogconfigshow max portlog entries = 8192 See Also portLogResize 486 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 513
that may be in place. Refer to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands none Examples To display the port log facility: switch:admin> portlogdisable See Also portLogEnable Fabric OS Command Reference 487 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 514
: WARNING: port log is disabled Refer to the portLogClear command for more information. For a full explanation of the information displayed by this command, refer to the Fabric OS Administrator's Guide. Operands This command has the following operands: count Specify the maximum number of lines - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 515
Availability" for details. Operands This command has the following operand: portid Specify the port area or index number. Examples To display the port log dump for a port: switch:user> portlogdumpport 14 time task event port cmd args 08:35:27.899 tShell pstate 14 OL1 08:35:27.899 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 516
that may be in place. Refer to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands none Examples To enable the port log facility: switch:admin> portlogenable See Also portLogDisable 490 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 517
information about the ID associated with the various port log events. The Disabled field indicates whether the port log for that event ID is disabled (1) or enabled (0). Operands none Examples To display information about port log events: switch:admin> portlogeventshow ID Event-Name Disabled - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 518
24-bit Port ID of the attached device. WorldWideName The port's World Wide Name. credit The credit for this login as appropriate. This is BB (buffer-to-buffer) credit for Flogs and EE (end-to-end) credit for PLOGIs. df_sz The default frame size for this login. cos Class of Services supported - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 519
part of the environmental monitor. A setting of 1 will enable logging of Port Discovery parameters. The PDISC log is disabled by default. debug_pdisc_flag. The default is 0. Examples To set the debug_pdisc_flag: switch:admin> portlogpdisc 1 PDISC log setting = 1 See Also none Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 520
Domain restrictions that may be in place.Refer to chapter 1, "Understanding Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands none Examples To enable the port log: switch:admin> portlogreset See Also none 494 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 521
Specifies the number of port log entries. The valid range of values is 32,768 to 65,536 for the Brocade 48000 and the Brocade 7500. For all other platforms, the range is 8,192 to 16,384. Examples To resize the portlog: switch:admin> portlogresize 12288 See Also portLogConfigShow Fabric OS - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 522
displays the same information as portLogDump, but it enables you to press Enter after each page of output. Port logs are circular log files in the switch firmware, which can save up to 32,768 entries. Refer to portLogConfigShow to display the current port log size. Once the log has reached the - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 523
nsRemQ rscn xalloc xfree xerr xstate payload Port Cmd ioctl Tx & Rx scn pstate ctin fc f8 ctout errlog loopscn OLP LIP LIM BMP OLD TMO Args start disable Speed negotiation states. Incoming Fibre Channel information unit. Outgoing Fibre Channel information unit. Information unit header log from - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 524
2 portLogShow enable Tx & Rx reject busy 1 is valid, 0003 means arguments 1 and 2 are valid). [B] the CT-based service command code. Argument 1 is the first word of the CT payload, if applicable timeout. 94 F0F0ARB(F0) timeout. 40 CLS timeout. 498 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 525
LIP reason 8001 Retry loop init. 8002 Start loop after gaining sync. 8003 Restart loop after port reset. 8004 LIP when a loop hangs. 8005 Restart loop if LIP received when sending out ARB . WS Wait for signal. NF Negotiation follows. Fabric OS Command Reference 499 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 526
the saved log is displayed. This operand is optional. . Examples To view the port log for a port: switch:user> portlogshow 24 time task event port cmd args 17:05:30.384 PORT Rx 0 40 02fffffd,00fffffd,08fbffff,14000000 17:05:30.384 PORT Tx 0 0 c0fffffd,00fffffd,08fb0e02 17:05:30.384 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 527
portid Specify the number of the port for which to display the log. Examples To display a port log for port 14: switch:user> portlogshowport 14 time task event port cmd args 08: (output truncated) See Also portLogClear, portLogShow, upTime Fabric OS Command Reference 501 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 528
values corresponding to different log types can be obtained by running portLogEventShow. Examples To disable event 2 from reporting to the port log: switch:admin> portlogtypedisable 2 See Also portLogDisable, portLogEventShow, portLogTypeEnable 502 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 529
corresponds to the port log type to be enabled. The values corresponding to different log types can be obtained by running portLogEventShow. Examples To enable event 2 to report to the port log: switch:admin> portlogtypeenable 2 See Also portLogEventShow, portLogTypeDisable Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 530
port N->N path. Synopsis portloopbacktest [--slot number][-nframes count][-lb_mode mode][-spd_mode mode] [-ports itemlist] Description Use this command to verify the functional operation of the switch by sending frames from the port " for details. 504 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 531
slot (--slot) are used. See itemList for more information on the itemlist parameter. Examples To run a functional test of a connection: switch:admin> portloopbacktest -ports 1/10-1/20 -nframes 1 -lb_mode 1 Running Port Loopback Test .... passed. Fabric OS Command Reference 505 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 532
2 portLoopbackTest Diagnostics Following are possible error messages if failures are detected: DATA ERRSTAT INIT PORTDIED STATS TIMEOUT XMIT Refer to the Fabric OS Message Reference for more information. See Also itemList 506 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 533
not been hardware-configured due to at least one port not being online. A connection that is "Enabled" has been configured in the hardware. A new connection cannot conflict with a "Defined" or "Enabled" port mirror connection. To display all configured mirror ports on a switch, use the portCfgShow - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 534
cannot both be 0x000000. Examples To configure a port as a mirror port: switch:admin> portcfg portmirror 2/1 --enable Please confirm enable of Mirror Port: 17 (Y,y,N,n): [n] y To add a port mirror connection between two local switch ports: switch:admin> portmirror --add 2/1 0x011400 0x012400 To - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 535
delete 0x011400 0x240400 To display port mirror connections: switch:admin> portmirror --show Number of mirror connection(s) configured: 2 Mirror_Port SID DID State 10/12 0x791800 0x791900 Defined 10/15 0x791a00 0x799300 Enabled See Also portCfgShow Fabric OS Command Reference 509 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 536
This command has the following operands: slotnumber For bladed systems only, specify the slot number of the port to be configured, followed by a slash (/). portnumber Specify a port number to be configured, relative to its slot for bladed systems. Use switchShow to display a list of valid - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 537
ports on the switch. Output includes the number of bytes received plus the number Default is one second. This operand is optional. When fastwrite or tape pipelining is enabled device port. Examples To display port throughput for a switch: switch:user> Fabric OS Command Reference 511 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 538
For bladed systems only, specifies the slot number of the port to display, followed by a slash (/). portnumber Specifies the number of the port to display, relative to its slot for bladed systems. Use switchShow to display a list of valid ports. 512 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 539
switch:user> portrouteshow 4/15 port address ID: 0x02bf00 external unicast routing table: 1: 0x4 (vc=3) 2: 0x10000 (vc=0) internal unicast routing table: 60: 0x8000 (vc=2) 63: 0x1000 (vc=5) broadcast routing table: 0x10000 See Also bcastShow, fabricShow, switchShow, topologyShow, uRouteShow Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 540
command displays specific FCIP related port configuration parameters, such as the following: • Address resolution protocol (ARP) entries • IP interfaces on the GbE port • Static routes on the IP interfaces • Fibre Channel over IP (FCIP) tunnel configuration settings • Port Mode information • FICON - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 541
. portId The port's 24-bit port ID. portIfId The user port's interface ID. portWwn The port's World Wide Name. portWwn of devices(s) connected The World Wide Port Names of connected devices. Distance The port's long-distance level. In case of LD mode, the user configured distance and actual - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 542
supported on EX_Ports. DH Group Displays DH group [0-4] if DH-CHAP authentication is used. Otherwise displays N/A. Hash Algorithm Displays hash type (MD5 or SHA-1) if DH-CHAP authentication is used. Otherwise, displays N/A. Edge fabric's primary WWN If the EX_Port is connected to an edge switch - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 543
Ports is a part of the current AD, the complete device information attached to the port is shown in the output. This command supports the following port options: slot For bladed systems only, specify the slot number of the port to be configured -enabled tunnels. Security policies are configured - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 544
configuration settings. ftrace FTRACE is a debug tool for developers and support (not intended for customer use). For usage information, execute portShow ftrace. Examples To display the state of a port: switch 64 Segmented port generation number: 12 portId: Fabric OS Command Reference 53-1000599 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 545
: 3 Port part of other ADs: No To view xlate domains, you must be running a Brocade 7500 or 48000 with an FC4-18i blade. Note that the Front Domain ID is what is shown: switch:admin> portshow 8/4 portName: portHealth: No Fabric Watch License Authentication: None EX_Port Mode: Enabled Fabric ID - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 546
Port part of other ADs: No To display IPv4 interfaces on a GbE port: switch:admin> portshow ipif 10/ge0 Slot: 10 Port: ge0 Interface IP ISCSI Port WWN and Sessions: switch:admin> portshow iscsi 2/ge0 GE Port 2/ge0 Port WWN Sessions 50:06:06:9e:40:09:a2:00 0 520 Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 547
as control connection: switch:admin> portshow fciptunnel 9/ge0 0 -params Slot: 9 Port: ge0 Tunnel ID 0 Remote IP Addr 10.62.0.100 Local IP Addr 10.10.9.100 Remote WWN Not Configured Local WWN 10: 90 ms, variance 0 peer advertised window 26998784 Bytes Fabric OS Command Reference 521 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 548
on an FCIP tunnel: switch:admin> portshow fciptunnel 9/ge0 0 -perf Slot: 9 Port: ge0 Tunnel ID 0 Remote IP Addr 10.62.0.100 Local IP Addr 10.10.9.100 Remote WWN Not Configured Local WWN 10:00: pkt/s 30s avg, 5 pkt/s lifetime avg 34118172 output Bytes 522 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 549
port: switch:admin> portshow fciptunnel 9/ge0 0 -ipsec Slot: 9 Port: ge0 Tunnel ID 0 Remote IP Addr 10.62.0.100 Local IP Addr 10.10.9.100 Remote WWN Not Configured Diffie-Hellman Group: 14 SA Life (seconds): 28800 IPSec Policy 1 Authentication Algorithm: SHA-1 Fabric OS Command Reference 523 53- - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 550
path credit data: switch:admin> portshow fciptunnel 9/ge0 0 -credits Slot: 9 Port: ge0 Tunnel ID 0 Remote IP Addr 10.62.0.100 Local IP Addr 10.10.9.100 Remote WWN Not Configured Local WWN 10:00 Knobs for tuning Credit processing: 524 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 551
1 IPSec Policy 1 Pre-Shared Key testingFIPSandIPSec To display QoS Mappings: switch:admin> portshow fciptunnel 9/ge0 0 -qosmap Slot: 9 Port: ge0 Tunnel ID 0 Remote IP Addr 10.62.0.100 Local IP Addr 10.10.9.100 Remote WWN Not Configured Local WWN 10:00:00:05:1e:39:d4:5a Compression on - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 552
2 portShow This command displays the same information as the previous but posts selected statistical areas: switch:admin> portshow ficon ge0 all -fdcb 10008000 -clear See Also authUtil, portCfg, portCfgLongDistance, portLoginShow, portName, switchShow 526 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 553
Number of frames with CRC errors. er64_trunc Number of frames shorter than minimum. er64_toolong Number of frames longer than maximum. er_bad_eof Number of frames with bad end-of-frame. er64_enc_out Number Tx peak Byte rate (Bps). Fabric OS Command Reference 527 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 554
port number to be displayed, relative to its slot for bladed systems. Use switchShow to display a list of valid ports. Examples To display the 64-bit hardware statistics for a port: switch:user maximum 0 bottom_int : Frames longer than maximum 528 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 555
2 er_bad_eof 0 top_int : Frames with bad end-of-frame 0 bottom_int : Frames with bad end-of-frame er64_enc_out 0 top_int : Encoding error words transmitted 0 bottom_int : 4-byte words transmitted See Also portStatsClear, portStatsShow Fabric OS Command Reference 529 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 556
a slash (/). port Specify a port number to be cleared, relative to its slot for bladed systems. Use switchShow to display a list of valid ports. Examples To clear hardware statistics for a port: switch:admin> portstatsclear 4/15 See Also portStats64Show, portStatsShow 530 Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 557
ordered sets (platform- and port-specific). er_c3_timeout The number of class 3 frames discarded due to timeout (platform- and port-specific). er_c3_dest_unreach The number of class 3 frames discarded due to destination unreachable (platform and port specific). Fabric OS Command Reference 531 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 558
a port number to be configured, relative to its slot for bladed systems. Specify the optional ge option to display the GbE port hardware statistics. Use switchShow to display a list of valid ports. ge Displays the GbE statistics. ip Displays all the GbE port statistics related to IP addresses - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 559
minimum Frames longer than maximum Frames with bad end-of-frame Encoding error outside of frames number of times FL has the tenancy number of times NL has the tenancy zero tenancy To display GbE port statistics for slot 8 and GbE port 1: switch Fabric OS Command Reference 533 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 560
8, and GbE port 1: switch:admin> portstatsshow ip 8/ge1 ip_err_crc ip_err_hdr_cksum ip_err_tcp_data_chksum 0 IP CRC Errors 0 IP Checksum Errors 0 IP TCP Data Checksum Errors To display port statistics for IP address 192.168.255.10, slot 8, and GbE port 1: switch:admin> portstatsshow ip 8/ge1 192 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 561
, relative to its slot for bladed systems. Examples To swap area numbers between a pair of ports: switch:admin> portswap 1/3 2/5 portswap done See Also portDisable, portEnable, portShow, portSwapDisable, portSwapEnable, portSwapShow, switchShow Fabric OS Command Reference 535 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 562
the portswap feature is persistent across reboots and power cycles. Enabling or disabling the portswap feature does not affect previously performed portswap switch:admin> portswapdisable See Also portSwap, portDisable, portEnable, portShow, portSwapEnable, portSwapShow, switchShow 536 Fabric OS - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 563
Restrictions" and Appendix A, "Command Availability" for details. Operands none Examples To enable the portswap feature: switch:admin> portswapenable See Also portSwap, portDisable, portEnable, portShow, portSwapDisable, portSwapShow, switchShow Fabric OS Command Reference 537 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 564
of the portswap feature, as well as port and area information for ports whose area number differs from the default area number. The default area number of a port is the same as its switch port number. Operands none Examples To display the enabled state of the portswap feature and information for - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 565
"Command Availability" for details. Operands This command has the following operands: -ports itemlist Specify a list of user ports to test. By default, all the user ports in the switch are tested. Refer to itemList help pages for further details. Fabric OS Command Reference 539 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 566
for porttype: -1 All ports (default). -2 All L_Ports. -3 All F_Ports. -4 All E_Ports. -5 All N->N loopback ports. Examples To run a functional test on an active switch: switch:admin> porttest -ports 1/1-1/3 See Also portLoopbackTest, portTestShow, spinFab, stopPortTest 540 Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 567
user ports to test. By default, all user ports in the current slot is assumed. Refer to the itemList help page for further details. Examples To display information from portTest: switch:admin> porttestshow 1 Port , portTest, spinFab, stopPortTest Fabric OS Command Reference 541 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 568
Trunk Master, Slave, or --. Master Displays the master port of the trunk group. TA On standalone switches, displays the user assigned TA number. DA On standalone switches, displays the default port area. The default area can be a port swapped area. TI On enterprise-class platforms, displays - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 569
supported on ports 16 - 47. 12. Ports included in a TA share the same port index. The original port index may be removed in the process. This means that D, I zones referring to these indices are no longer part of the switch. For details and workarounds, refer to the Fabric OS Administrator's Guide - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 570
which masterless F_Port trunking is enabled). disabled Displays configuration details for all ports not included in a user assigned TA (all portson which masterless F_Port trunking is notenabled). all Displays configuration details for all ports on a switch. 544 Fabric OS Command Reference 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 571
the TA. 2. Enable Trunk Area for ports 36 - 39 with area number 37: switch:admin> porttrunkarea --enable 36-39 -area 37 Trunk area 37 enabled for ports 36, 37, 38 and 39. 3. Re-enable ports 36-39 by executing portenable port for each port in the TA. 4. Show switch/port information: switch:admin - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 572
-index 125 Trunk index 125 enabled for ports 10/13 and 10/14. 3. Show the TA port configuration (ports still disabled): switch:admin> porttrunkarea --show enabled Slot Port Type State Master TI DI 10 13 -- -- -- 125 125 10 14 -- -- -- 125 126 546 Fabric OS Command Reference 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 573
Show the TA port configuration after enabling the ports: switch:admin> porttrunkarea --show enabled Slot Port Type State Master TI DI 10 13 F-port Master 10/13 125 125 10 14 F-port Slave 10/13 125 126 portCfgTrunkPort, portCfgShow, portShow, switchCfgTrunk, switchShow Fabric OS Command Reference - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 574
a switch. Output shows virtual port number (decimal), physical port number (decimal), online status, and if online, port type. If the current zone configuration has been disabled by cfgDisable, the fabric is in non-zoning mode, in which all devices see each other. When default zoning is enabled with - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 575
a power supply goes out of service or a field-replaceable unit ( processors to cease executing the firmware. For example, if only switch:admin> powerofflistset Slot Current POL 10 1st 9 2nd 8 3rd 7 4th 4 5th 3 6th 2 7th 1 8th 1st slot to be powered off: (1..10) [10] 1 Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 576
8 3 3rd 7 4 4th 4 10 5th 3 9 6th 2 8 7th 1 7 8th Proceed to change the POL order? (yes, y, no, n): [no] y See Also chassisShow, powerOffListShow, psShow, slotPowerOff, slotPowerOn, slotShow 550 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 577
a power supply goes out of service or a field-replaceable unit (FRU the CP board processors to cease executing the firmware. For example, if only one power supply the slot power off list order: switch:admin> powerofflistshow Slot 10 will be powered Fabric OS Command Reference 551 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 578
supply unit installed. predicting failure Power supply is present but predicting failure. faulty Power supply present but faulty (no power cable, power switch turned off, IXD0111000088 IXD0111000162 IXD0111000120 See Also chassisShow, fanShow 552 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 579
. Synopsis reboot -f Description When this command is issued on a switch, if the switch is part of a fabric, all traffic to and from that switch stops. All Fibre Channel ports on that switch including E_Ports become inactive until the switch comes online. You are warned to commit to the reboot - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 580
settings to default values Displays the user-defined IOD delay settings in the fabric. Set or print the FSPF cost of a link Displays the FSPF link state database Display FSPF (TM) neighbors' states Reset the FSPF (TM) interface counters Display the unicast fabric topology Configure a static route - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 581
and later, the maximum security database size is 1 Megabyte. For switches running earlier versions of Fabric OS (up to v5.3.0), the maximum is 256 Kilobytes. Notes The effective security DB size is the lowest supported by the fabric. The presence of a Standby CP that runs an earlier version of - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 582
. If switch is configured to do DH-CHAP, it is performed whenever a port or a switch is enabled. Warning: Please use a secure channel for setting secrets. Using an insecure channel is not safe and may compromise secrets. Following inputs should be specified for each entry. 556 Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 583
setting up shared secrets > Enter WWN, Domain, or switch name (Leave blank when done): 10:00:00:60:69:80:05:14 Enter peer secret: Re-enter peer secret: -CHAP secret keys. If a fabric requires authentication, deleting this database may cause switch to segment from the fabric. Do want to remove secret - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 584
[-enable https]] [-protocol ftp | scp] [-ipaddr IP address] [-remotedir remote directory ] [-certname certificate name] [-login login name] [-password password] seccertutil show [-ldapcacert] | [file name] Description Use this command to manage third-party certificates on a switch, including - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 585
quotes. -locality locality Specifies the city. Provide the full name, for example, "San Jose". If the locality consists of multiple words, it Domain Name, or IP address. showcsr Fabric OS Command Reference 53-1000599-02 Displays the content of the CSR on the switch without page breaks. Use - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 586
. -ipaddr IP address Specifies the IP address of the remote host. -remotedir remote directory Specifies the remote directory. Provide a fully qualified path name. -login login name Specifies the login name for the server. -password password Specifies the password for the user account. When - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 587
name for the server. -password password Specifies the password for the user account. When using SCP, for security reasons, do not enter a password on the command line. Use the interactive version instead. show Lists all existing PKI-based certificates on the switch. The following operands are - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 588
. To import a PKI-based certificate with configure and enable option in non-interactive mode: switch:admin> seccertutil import -config swcert -enable https -protocol ftp \ -ipaddr 195.168.38.206 -remotedir /users/home/remote_certs -certname file.crt \ -login abcd -password passwd Success: imported - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 589
secCertUtil 2 Enter remote directory: /users/home/remote/mycerts Enter Login Name: username Enter LDAP certificate name (must have ".pem" \ suffix):filename.cer Password:password Success: exported LDAP certificate To export an LDAP CA certificate from the local switch to a remote host in non- - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 590
OS v6.0.0 and later, the maximum security database size is 1 MB. For switches running earlier versions of Fabric OS (up to v5.3.0), the maximum is 256 KB. The effective security DB size is the lowest supported by the fabric. The presence of a Standby CP that runs an earlier version of the operating - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 591
support staff. The information displayed may not be supported : switch:admin enabled sec_aca: free RCS latest Phase: Completion RCS Message ==> RCS transaction completes. ----DataBase STATUS---Retry Role 0 Retry Qeury0 Security Active DataSize 35 bytes -----Domain State----- Active Sum 215b Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 592
secGlobalShow Security Defined DataSize 35 bytes Define Sum 215b Zone Size (include enabled configuration) 312 bytes Zone sum e04b215b sec_db: free primaryDLPhase 0 ----wwnDL completion [Output truncated] See Also secActiveSize, secDefineSize 566 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 593
secpolicysave secpolicyshow secstatsreset secstatsshow Configure FIPS mode operation Creates public policy set and sends to all switches Shows members of one or more policies Resets security statistics Displays security statistics See Also none Fabric OS Command Reference 567 53-1000599- - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 594
to policy creation and modification operations from all the switches if a fabric-wide consistency policy is not set for the particular policy. Notes When FCS Policy is enabled, this command can be issued only from the Primary FCS switch. Only the user who made the changes to the defined database - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 595
Policy Sets. Notes The behavior of this command is the same for tolerant and strict fabric-wide consistency. When FCS Policy is enabled, this command can be issued only from the Primary FCS switch. Any modifications to the SCC, DCC, and FCC DB are saved and activated. When secPolicyActivate - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 596
enabled, this command can be issued only from the Primary FCS switch. The secpolicyadd command can be issued on all switches for SCC and DCC policies as long as fabric has the common prefix DCC_POLICY_ followed by a string of user-defined characters. These characters do not have to be capitalized - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 597
all devices attached to those ports. [*] Selects all ports on the switch and devices currently attached to those ports. Examples To add a member to the SCC_POLICY using the device WWN: primaryfcs:admin> secpolicyadd "SCC_POLICY", "12:24:45:10:0a:67:00:40" Member(s) have been added to SCC_POLICY - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 598
[, "member[;member...]"] Description Use this command to create a new policy and to edit Switch Connection Control (SCC), Device Connection Control (DCC), and Fabric Configuration Server (FCS) policies on the local switch. All policies can be created only once, except for the DCC_POLICY_nnn. Each - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 599
DCC_POLICY does not stop access to the switch. The device is specified by its port WWN. The switch and port combination must be in the switch port format switch can be specified using a WWN, domain, or switch name. port can be specified by port numbers separated by commas and enclosed in either - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 600
To create a SCC policy in a Fabric with three switches: 1. Check if a policy exists. switch:admin> secpolicyshow ACTIVE POLICY SET DEFINED POLICY SET 2. Identify switches in the fabric. switch:admin> fabricshow Switch ID Worldwide Name Enet IP Addr FC IP Addr Name 2: fffc02 10:00:00 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 601
string of user-defined characters. These characters do not have to be capitalized. ALL_DCC_POLICY Deletes all DCC policies from the defined policy list. SCC_POLICY Deletes the Switch Connection Control (SCC) policy from the defined policy list. FCS_POLICY Deletes the Fabric Configuration Server - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 602
2 secPolicyDelete See Also secPolicyAbort, secPolicyActivate, secPolicyAdd, secPolicyCreate, secPolicyDump, secPolicyRemove, secPolicySave, secPolicyShow 576 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 603
" for details. This command can be issued from all FCS switches in the fabric. Operands This command has the following operands: "listtype" Specify name has the common prefix DCC_POLICY_ followed by a string of user-defined characters. These characters do not have to be capitalized like - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 604
2 secPolicyDump See Also secPolicyAbort, secPolicyActivate, secPolicyAdd, secPolicyCreate, secPolicyDelete, secPolicyRemove, secPolicySave, secPolicyShow 578 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 605
position in the FCS list. Only one FCS can be moved at a time. The first FCS switch in the list that is also present in the fabric is the Primary FCS. FCS Policy must be enabled on the switch to execute this command. Notes If a backup FCS is moved to the first position, it - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 606
, y, no, n): [no] y secpolicyactivate command was completed successfully. switch:admin> secpolicyshow ACTIVE POLICY SET FCS_POLICY Pos Primary WWN DId swName 1 Yes , secPolicyDump, secPolicyRemove, secPolicySave, secPolicyShow 580 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 607
devices associated with a specific switch and port combination. The device is specified with a WWN string. The switch and port combination must be specified in the switch port format where switch can be specified by switch WWN, domain, or switch name. The port Fabric OS Command Reference 581 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 608
all devices attached to those ports. [*] Selects all ports on the switch and devices currently attached to those ports. Examples To remove a member that has a WWN of 12:24:45:10:0a:67:00:40 from SCC policy: switch:admin> secpolicyremove "SCC_POLICY", "12:24:45:10:0a:67:00:40" Member(s) have been - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 609
saves the modified SCC, DCC, and FCS policies to the Defined Security Policy Set on the local switch. Notes This command is always a local switch operation. A fabric-wide consistency configuration does not affect the behavior of this command. The execution of this command is subject to Admin - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 610
prefix DCC_POLICY_ followed by a string of user-defined characters. These characters do not have switch:admin> secpolicyshow "active ACTIVE POLICY SET FCS_POLICY Pos Primary WWN DId swName 1 Yes 10:00:00:60:69:30:15:5c 1 primaryfcs 2 No 10:00:00:60:69:30:1e:62 4 switch 584 Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 611
WWN DId swName 1 Yes 10:00:00:60:69:30:15:5c 1 primaryfcs 2 No 10:00:00:60:69:30:1e:62 4 switch fddCfg, secPolicyAbort, secPolicyActivate, secPolicyAdd, secPolicyCreate, secPolicyDelete, secPolicyDump, secPolicyRemove, secPolicySave Fabric OS Command Reference 585 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 612
command can be issued on any switch to reset the security statistics on the local switch or chassis. If FCS policy is enabled and secStatsReset is issued on the primary FCS switch, this command can reset security statistics for any or all switches in the fabric. Note The execution of this command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 613
of domain IDs on which to reset the security statistics. Specify an asterisk (*) to represent all switches in the fabric or specify a list of domains, separated by semicolons and enclosed in quotation marks. This option can only be executed when FCS policy is enabled and when the command is issued - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 614
to display local security statistics. If FCS policy is enabled and secStatsShow is issued on the primary FCS switch, this command can retrieve and display the security statistics for any or all switches in the fabric. Operands When invoked without operands, this command displays the security - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 615
an asterisk (*) in quotation marks to represent all switches in the fabric or specify a list of domains separated by semicolons. This option can only be executed when FCS policy is enabled and the command is issued from the primary FCS switch. When domain is specified, the name operand is required - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 616
sensors located on the switch. The actual location of the sensors varies, depending on the switch type. Operands none Examples To view all sensor values: switch:admin> sensorshow sensor 1: 13: (Power Supply ) is Absent See Also fanShow, tempShow 590 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 617
debug messages to the serial console. By default, no debug messages are displayed. High debug system response time. The set of supported modules and their current debug levels switch:admin> setdbg NS 3 switch:admin> dbgshow NS Module NS, debug level = 3, verbose level = 0 See Also dbgShow Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 618
to a CP modem serial port. When the CP is active and dial-in is enabled, the modem is configured to answer an incoming call on the first ring. When the CP is standby and dial-in is enabled, the modem is configured to answer an incoming call on the seventh ring. Fabric OS Command Reference 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 619
configuration, a separate modem is connected to each modem port of Enables modem dial-in. -d Disables modem dial-in. Examples To disable modem dial-in to a CP: switch:admin> setmodem -d disabling modem, please wait, this can take a couple of minutes... modem disabled See Also none Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 620
filter the display of the debug message to the serial console. By default, no debug messages are displayed. Note The execution of this command is 3: switch:admin> setverbose NS 3 switch:admin> dbgshow NS Module NS, debug level = 0, verbose level = 3 See Also dbgShow, setDbg 594 Fabric OS - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 621
number of the port for which to display the SFP information, relative to its slot for bladed systems. Use switchShow for a list of valid ports. This operand is optional; if omitted, this command displays a summary of all SFPs on the switch Fabric OS Command Reference 595 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 622
detailed SFP information for a Finisar "smart" SFP: switch:user> sfpshow 1/3 Identifier: 3 SFP Connector: 7 LC uWatts To display detailed information for GbE port 0 on a Brocade 7500: switch:admin> sfpshow ge0 Identifier: 3 SFP 020313 596 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 623
Code: 020511 To display all SFP information: switch:user> sfpshow -all Port 0: Identifier: 3 SFP Connector: 7 LC Port 1 Identifier: 3 SFP Connector: 7 LC Transceiver: 050c402000000000 100,200_MB/s M5,M6 sw Inter_dist Encoding: 1 8B10B Baud Rate: 21 (units 100 megabaud) Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 624
Vendor Rev: AA10 Wavelength: 0 (units nm) Options: 001a Loss_of_Sig,Tx_Fault,Tx_Disable BR Max: 5 BR Min: 5 Serial No: 21P70530005BW Date Code: 01062301 (output truncated) switchShow 598 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 625
is disabled by default. Because this command changes the flow control on the console serial port, it must be executed from a session that is logged in from the console serial port. This command cannot run from a Telnet session. This setting is saved in the configuration database; therefore, it - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 626
Admin Domain Restrictions" and Appendix A, "Command Availability" for details. Operands none Examples To enable flow control: switch:admin> shellflowcontrolenable Enabling flowcontrol flow control is now enabled See Also shellFlowControlDisable 600 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 627
: slotnumber Specify the slot number of the blade to be powered down. This operand is required. Examples To power off blade unit 3: switch:admin> slotpoweroff 3 Slot 3 is being powered off See Also powerOffListSet, powerOffListShow, slotPowerOn, slotShow Fabric OS Command Reference 601 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 628
This command has the following operand: slotnumber Specify the slot number of the blade to be powered on. This operand is required. Examples To power on blade unit 3: switch:admin> slotpoweron 3 Powering on slot 3. See Also slotPowerOff, slotShow 602 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 629
processor blade 17 FC4-16 port blade 18 FC4-32 port blade 24 FR4-18i port blade 31 FC4-16IP port blade 33 FA4 -18 port blade 36 FC4-48 port blade 39 FC10-6 port blade 50 CP8 control processor blade 52 Core8 switch blade 37 FC8-16 port blade 55 FC8-32 port blade 51 FC8-48 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 630
name for each blade. Examples To display a basic view of all slots and their status: switch:user> slotshow Slot Blade Type ID Status 1 SW BLADE 51 FAULTY 2 SW BLADE 51 DISABLED 3 SW BLADE 55 ENABLED(User Ports Disabled) 4 SW BLADE 51 DIAG RUNNING POST2 5 CORE BLADE 52 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 631
: 9.91 watts per port, 2.48 watts per Gb To display Brocade model names for each blade in the chassis: switch:user> slotshow -m Slot Blade Type ID Model Name Status 1 AP BLADE 33 FA4-18 ENABLED 2 SW BLADE 55 FC8-32 ENABLED 3 SW BLADE 37 FC8-16 ENABLED 4 SW BLADE 39 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 632
this command to manage the configuration of the SNMP agent in the switch. The configuration includes SNMPv1 and SNMPv3 configuration, access control list (ACL), MIB capability, system group, and security level settings. The command supports set, reset to default, and display operations. All values - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 633
s enabled, community strings can be changed on the primary FCS switch only, and only the primary FCS switch propagates changes across the fabric. For an SNMP management station to receive a trap generated by the agent, the administrator must configure a trap recipient to correspond to the IP address - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 634
option sets the user name and password to default. If FCS policy is enabled, the configuration has to be updated on both primary and nonprimary switches, and unlike community strings, user names and passwords are not distributed for other switches in the fabric. When new passwords are entered for - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 635
Group Configuration Parameters sysDescr The system description. The default value is Fibre Channel Switch. sysLocation The location of the system (switch). The default value is End User Premise. sysContact The contact information for this system (switch). The default value is Field Support - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 636
configured yet To set the SNMPv1 configuration of a switch: switch:admin> snmpConfig --set snmpv1 SNMP community and trap recipient configuration: Community (rw): [Secret C0de] Trap Recipient's IP t, false, f): [true] Committing configuration...done. 610 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 637
configuration to default values: switch:admin> snmpconfig --default systemGroup ***** This command will reset the agent's system group configuration back to factory default ***** sysDescr = Fibre Channel Switch sysLocation = End User Premise sysContact = Field Support (1..3) [1] Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 638
on SNMP: Fabric OS MIB Reference SW_v5_x.mib, "Switch Management Information & Switch Enterprise Specific Trap" RFC1157, "A Simple Network Management Protocol (SNMPv1)" RFC1213, "Management information Base for Network Management of TCP/IP-based internets: MIB-II" RFC2574, "User-based Security Model - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 639
and the actual number of frames sent will be slightly larger, particularly at 2 Gbps link speeds. -ports itemlist Specify a list of user ports to test. By default, all of the ISL ports in the current switch are tested. Refer to itemList help pages for further details. Fabric OS Command Reference - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 640
This mode is disabled by default. Examples To test cascading ISL links: switch:admin> spinfab -ports 1/0 - 1/2 spinfab running... spinfab: Completed 11 megs, status: passed. port 0 test status: 0x00000000 -- passed. port 1 test status: 0x00000000 -- passed. port 2 test status: 0x00000000 -- passed - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 641
Refer to the Fabric OS Message Reference for more information. See Also itemList, portLoopbackTest spinFab 2 Fabric OS Command Reference 615 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 642
to enable and manage SSH public key authentication on a switch. SSH public key authentication provides a mechanism for authenticating an authorized user without a password. SSH public key authentication is more secure than password authentication and can be used to securely access services that - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 643
Enter the IP address for the remote host. IPv4 and IPv6 addresses are supported. remote directory Enter the path to store the public key. The default directory where SSH stores public keys is ~username/.ssh. login name Enter the user name for the configured user. password Enter the password for - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 644
letters, numbers, and IP Address, remote directory, login name and password. Refer to importpubkey for a description of these parameters. delprivkey Deletes the private key for outgoing connection from the switch. This option can only be performed by a configured user. Deletion of a configured user - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 645
sshUtil 2 Password: public key is imported successfully. 3. Connect to switch using remote ssh client with the -i private_key option: username@remotehost> ssh username@switch IP address -i id_dsa To display the imported public keys on a switch: switch:username> sshutil showpubkeys user's public - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 646
for the blade ports specified in -bports clears. A value of zero (0) clears the user ports specified in -uports. The default value is 0. Examples To clear port and diagnostic statistics: switch:admin> statsclear -bports 1/10-1/62 -use_bports 1 See Also itemList 620 Fabric OS Command Reference - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 647
stopporttest [-ports itemlist] user ports to test. By default, all the user ports in the switch are tested. Refer to itemList help pages for further details. Examples To stop the portTest command: switch:admin> stopporttest See Also portLoopbackTest, portTest, portTestShow, spinFab Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 648
. Examples To display the FFDC configuration: switch:admin> supportffdc --show First Failure Data Capture (FFDC) is disabled. To enable the FFDC events: switch:admin> supportffdc --enable First Failure Data Capture (FFDC) is enabled. See Also none 622 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 649
, the supportFtp command defaults to supportFtp -S. Examples To set the FTP parameters: switch:admin> supportftp -s -h 1080::8:800:200C:417A -u njoe -p password -d support supportftp: ftp parameters changed. To display the FTP parameters: switch:admin> supportftp Fabric OS Command Reference 623 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 650
IP Addr[1080::8:800:200C:417A]:192.168.67.126 User Name[njoe]:admin Password[********]:password Remote Dir[support]:temp Auto file transfer parameters changed To display a time interval to check the FTP server: switch:admin> supportftp -t 24 supportftp: ftp check period changed. To enable auto - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 651
blades installed on the switch, a support file (a.tar.gz file) is generated from each slot. This command accepts IPv4 and IPv6 addresses. If the configured IP address is in IPv6 format, the RAS auto file transfer and event notification to syslog will not work in the case where the Fabric OS version - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 652
requests to copy files, it is important that the scp mode service be configured so that passwords are not required for each attempted transfer by the supportSave command. Failure to pretest and properly configure the service could result in significant delays in obtaining transferred output from the - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 653
. OK to proceed? (yes, y, no, n): [no]y Host IP or Host Name: 192.168.126.115 User Name: admin Password: Protocol (ftp or scp): ftp Remote Directory: /users/home/admin/support Saving support information for switch:art_saturn1, module:CONSOLE0... ...ave_files/art_saturn1-S6-200802171208-CONSOLE0.gz - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 654
/art_saturn1-S6-200802171211-CONSOLE1.gz: 7.45 kB 217.17 kB/s Saving support information for switch:art_saturn1, module:SSAVELOG... ...ave_files/art_saturn1-S6-200802171212-sslog.ss.gz: 1.88 kB 53.35 kB/s SupportSave completed See Also supportShow 628 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 655
exception Exception group commands, enabled by default. port Port group commands, enabled by default. fabric Fabric group commands, enabled by default. services Service group commands, enabled by default. security Security group commands, enabled by default. network Network group commands - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 656
:17 2008 Thu Feb 14 18:38:31 2008 4.6.6 supportshow groups enabled: os enabled exception enabled port enabled fabric enabled services enabled security enabled network enabled portlog enabled system enabled extend disabled filter disabled perfmon disabled ficon disabled iswitch - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 657
os | exception | port | fabric | services | security | network | portlog | systemextend | filter | perfmon | ficon | iswitch | asic_db |iscsi Description Use this command to disable a group of commands under the supportShow command. Use the supportShowCfgEnable command to enable groups of commands - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 658
the exception group commands. port Enables the port group commands. fabric Enables the fabric group commands. services Enables the service group commands. security Enables the security group commands. network Enables the network group commands. portlog Enables the portlog group commands - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 659
which groups of commands are enabled in the supportShow command: switch:admin> supportshowcfgshow os enabled exception enabled port enabled fabric enabled services enabled security enabled network enabled portlog enabled system enabled extend disabled filter disabled perfmon - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 660
Use this command to enable or disable switch beaconing mode. Switch beaconing can be used to locate a failing unit. When beaconing mode is turned on, the port LEDs flash amber, left to right and right to left, from port 0 to the highest port number and back to port 0. The beaconing mode continues - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 661
switch. All Fibre Channel ports are taken offline. If the switch was part of a fabric, the remaining switches reconfigure. The switch as each port is disabled. A persistently disabled switch can be temporarily enabled using the switchEnable command. A temporarily enabled switch remains disabled - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 662
command to persistently enable the switch. All Fibre Channel ports that passed the power-on self-test (POST) are enabled and come online if connected to a device, or remain offline if disconnected. The switch might need to be enabled if it was previously disabled to make configuration changes or to - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 663
at 2 Gbps. 4 4-Gbps mode. The port is fixed at 4 Gbps. 8 8-Gbps mode. The port is fixed at 8 Gbps. Examples To set the speed level for all ports on a switch: switch:admin> switchcfgspeed 0 Committing configuration...done. See Also portCfgSpeed, portShow Fabric OS Command Reference 637 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 664
1 to enable trunking on all ports. Specify 0 to disable trunking on all ports. Examples To disable trunking on all ports of a switch: switch:admin> switchcfgtrunk 0 Committing configuration...done. See Also portCfgShow, portCfgTrunkPort, portShow, portTrunkArea, switchShow 638 Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 665
Description Use this command to disable the switch. All Fibre Channel ports are taken offline; if the switch was part of a fabric, the remaining switches reconfigure. The switch must be disabled before making configuration changes (using configure or configDefault) or before running many of - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 666
to enable the switch. All Fibre Channel ports that passed POST are enabled. They can come online if connected to a device, or remain offline if disconnected. Use switchEnable if you disable the switch to make configuration changes or to run diagnostics. If the switch is connected to a fabric, it - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 667
this command to display or set the switch name. All switches have a symbolic name that is primarily used for switch management. This name is shown in the Fabric OS CLI prompt, under each switch icon on the Fabric Web page, and in the output of various Fabric OS commands, such as fabricShow. Use this - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 668
The backbone fabric ID for FC routing. The switch summary is followed by one-line description for non-EX_Ports and one or two lines for EX_Ports: Area Part of the 24-bit port ID, which consists of domain, area number, and optional AL_PA. Area column is only displayed for non-slot based platforms - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 669
. Module signaling a laser fault. Port marked faulty. Port failed diagnostics. Locking to the reference signal. Running diagnostics. Connection not established (for virtual ports only). Port is up and running. Protocol support by GbE port. Ports support ISCSI. Fabric OS Command Reference 643 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 670
FCIP Ports support FCIP. comment Optionally displays: Disabled Port is disabled. Bypassed Port is bypassed (loop only). Loopback Port is in loopback mode. E_Port Fabric port; displays WWN and name of attached switch. If the port is configured as EX_Port, the WWN of the attached switch is - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 671
if one of the L_Ports or NPIV Ports is a part of the current AD, the complete device information attached to the port is displayed. Operands This command has the following operands: -portcount Displays the number of ports on the switch. -iscsi Displays the number of ports on the iSCSI sessions - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 672
10:00:00:00:00:02:00:00 208 8 16 03d000 -- -- Offline [output truncated] 216 8 24 03d800 -- -- Online 10:00:00:60:69:e2:0c:00 "bot_4a3_a10" (upstream) 217 8 25 03d900 Port F-Port VE-Port VE-Port VE-Port VE-Port VE-Port VE-Port VE-Port VE-Port To display a switch in Access Gateway mode: switch - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 673
example, assuming that the switch contributor values are set to the default values, if there is one faulty port in a switch, then this contributor would set the overall switch status to MARGINAL. If two ports were faulty, then this contributor would set the overall switch status to DOWN. Note The - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 674
** the policy parameter is NOT applicable to the switch. ** Simply hit the Return key. The minimum number of Bad PowerSupplies contributing to DOWN status: (0..4) ) [0] Policy parameter set has been changed switchStatusPolicyShow, switchStatusShow 648 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 675
0 The policy parameters determine the number of failed or non-operational units for each contributor that trigger a status change in the switch. For example, if the FaultyPorts DOWN parameter is set to 3, and three ports fail in the switch, then the status of the switch changes to DOWN. Note The - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 676
2 switchStatusPolicyShow Flash 0 1 MarginalPorts 2 1 FaultyPorts 2 1 MissingSFPs 0 0 See Also switchStatusPolicySet, switchStatusShow 650 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 677
Use this command to display the overall status for a switch that is configured with IPv4 and IPv6 addresses. In addition, users with a Fabric Watch license are able to view the list of unhealthy ports. This command displays the overall switch status, and the status of the following contributors - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 678
is configured with an IPv4 address: switch:user> switchstatusshow Switch Health Report Switch Name: switch IP address: 10.32.89.26 SwitchState: MARGINAL Duration: 80:12 Report time: 09/11/2006 05:39:28 PM Power supplies monitor Temperatures monitor Fans monitor Flash monitor Marginal ports - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 679
Description Use this command to display the current time and the amount of time that the switch has been operational. Operands none Examples To view the uptime for the switch: switch:user> switchuptime 9:50pm up for 20 mins See Also none Fabric OS Command Reference 653 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 680
command displays the device WWN and the port where the violation occurred. Operands This support High Availability (HA). Examples To display DCC violations for a switch: switch:admin> switchviolation --dump -dcc Device WWN Port 22:00:00:04:cf:75:59:87 10 See Also none 654 Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 681
reads and forwards system messages to the appropriate log files or users, depending on the system configuration. The specified facility is used when forwarding messages to the servers added through the command syslogdIpAdd. The default facility is LOG_LOCAL7. Note The execution of this command is - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 682
servers are supported. You can specify a syslogd server in one of two ways: • By IP address: The syslogdipadd command accepts IPv4 and IPv6 addresses. • By host name: The host must have a DNS entry and accept DNS requests. The DNS name service must be configured on the switch with dnsconfig before - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 683
switch:admin> dnsconfig Enter option 1 Display Domain Name Service (DNS) configuration 2 Set DNS configuration 3 Remove DNS configuration 4 Quit Select an item: (1..4) [4] 2 Enter Domain Name: [] brocade.com Enter Name Server IP address in dot/colon notation: [] 192.168.126.120 Enter Name Server IP - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 684
. Synopsis syslogdipremove ip_address Description Use this command to remove the IP address of the server that is running the syslogd process and to which system messages are sent. IPv6 and IPv4 syslogd address configurations are supported. Note The execution of this command is subject to Admin - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 685
. IPv4 and IPv6 addresses are supported. Operands none Examples To display all syslog daemon IP addresses configured on a switch: switch:admin> syslogdipshow syslog.1 1080::8:800:200C:417A See Also errShow, syslogdFacility, syslogdIpAdd, syslogdIpRemove Fabric OS Command Reference 659 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 686
manually power off the system. To reboot the system, manually turn the power switch on. Notes This command is not supported : Switching to switch:admin> sysshutdown This command will shutdown the operating systems on your switch. You are required to power-cycle the switch INIT: Switching to runlevel - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 687
To attempt a system shutdown from the standby CP (not supported): switch:admin> sysshutdown Shut down the whole system is not support from the standby CP For shut down the whole system please run the sysshutdown from the active CP See Also haDisable Fabric OS Command Reference 661 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 688
designed to operate with switches connected to a fabric and restrict the frame loopback to inside the unit. If loopback plugs are installed in all ports, the burn-in parameter min_lb_mode can be changed to 1 to test the Fibre Channel through the loopback plug. Notes The switch must be offline for - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 689
. To initiate a system verification test on all switches in the fabric: switch:admin> systemverification -short systemverification: Setting parameters for short run. systemverification: burnin parameters. CURRENT - KEYWORD : DEFAULT 1 - number_of_runs : 1 2 - vib : 2 10 - thermal : 10 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 690
in a switch. For each sensor, this command displays the slot number (if switch:user> tempshow Index Slot State Centigrade Fahrenheit 1 1 Ok 41 105 2 2 Ok 39 102 3 3 Absent 4 4 Absent 5 5 Ok 26 78 6 6 Ok 27 80 See Also fanShow, psShow, sensorShow, slotShow 664 Fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 691
details. Operands This command has the following operand: timeval Specify the number of minutes for the Telnet timeout value. Valid values are 1 to : switch:admin> timeout 10 IDLE Timeout Changed to 10 minutes The modified IDLE Timeout will be in effect after NEXT login See Also none Fabric OS - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 692
The following rules apply: 1. On all switches, the command displays the number of domains in the fabric and the local Domain IDs. If translate domains are configured, existing translate domains and associated ports are displayed. 2. On an edge fabric, the command displays the following additional - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 693
all domains, including local domains and local translate domains: switch:user> topologyshow 6 domains in the fabric; Local Domain ID: 7 Domain: Metric: Name: Path Count: 1 10500 fcr_xd_1_1 1 Hops: Out Port: In Ports: Total Bandwidth: Bandwidth Demand: Flags: 2 11 0 1 2 3 4 5 6 7 8 9 15 8.000 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 694
for the three remote domains, not for the two local translate domains. switch:user> topologyshow 5 domains in the fabric; Local Domain ID: 2 Local Translate Domain 4 owned by port: 24 Local Translate Domain 5 owned by port: 23 33 Domain: Metric: Name: Path Count: 1 500 pengsaturn104 1 Hops: Out - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 695
See Also In Ports: Total Bandwidth: Bandwidth Demand: Flags: 23 24 33 38 39 8.000 Gbps 350 % D fcrXlateConfig, portRouteShow, uRouteShow topologyShow 2 Fabric OS Command Reference 669 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 696
dump, or to display the dump status on the switch. If there is no parameter specified, this command defaults to traceDump -S. The default remote file name format is chassisname-S#-YYYYMMDDHHMMSS.dmp, in which # is the slot number (0 on nonbladed systems) and YYYYMMDDHHMMSS (year-month-day-hour - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 697
Examples To display information on the track-changes commands: switch:admin> trackchangeshelp trackChangesSet Configure alert for login/logout/config update trackChangesShow Displays status of track changes See Also trackChangesSet, trackChangesShow Fabric OS Command Reference 671 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 698
optional. Examples To enable the track-changes feature: switch:admin> trackchangesset 1, 1 Committing configuration...done. switch:admin> trackchangesshow Track changes status: ON Track changes generate SNMP-TRAP: YES See Also snmpConfig, trackChangesHelp, trackChangesShow 672 Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 699
status of the track-changes feature. It shows whether the feature is enabled or disabled and if SNMP traps are generated. The output from the feature: switch:admin> trackchangesshow Track changes status: ON Track changes generate SNMP-TRAP: YES See Also trackChangesHelp, trackChangesSet Fabric OS - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 700
area numbers for a port. This operand is required. Examples To debug a trunk connection: switch:admin> trunkdebug 43 44 Switch does not support trunking switch:admin> trunkdebug 62 63 port 62 and 63 are trunked together See Also portCfgTrunkPort, switchCfgTrunk, trunkShow 674 Fabric OS Command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 701
are part of this trunking group are displayed. Port to port connections Displays the port-to-port trunking connections. WWN Displays the WWN of the connected port. Domain Displays the domain IDs of the switches directly connected to the physical ports. In case of a FC Router backbone fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 702
16 4 deskew 17 4 deskew 17 4 deskew 15 4 deskew 16 switch:admin> switchshow 48 4 0 013000 id N4 Online EX-Port (Trunk port, master is Slot 4 Port 1 ) 49 4 1 013100 id N4 Online EX-Port 10:00:00:05:1e:35:b3:03 "SW4100_33" (fabric id = 100 )(Trunk master) E-Port 50:00:51:e3:70:bb:af:c1 "fcr_xd_9_100 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 703
enable fabric-wide clock synchronization with the specified clock server. A value of LOCL may be specified as operand to set the clock server back to default. Each ipaddr specified should be the IP address of an NTP server and should be accessible from the switch. The NTP server must support a full - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 704
.123.123.123 Updating Clock Server configuration...done. switch:admin> tsclockserver 123.123.123.123 To configure multiple NTP servers: switch:admin> tsclockserver "12.134.125.24; 12.234.87.01" Updating Clock Server configuration...done. See Also date 678 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 705
switches in a fabric are located in the same time zone, you may leave the default time zone setup. Time zone is used in computing local time for error reporting and logging. An incorrect time zone setup does not affect the switch operation in any way. System services Specifies the number of hours - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 706
in name format. Examples To display the current time zone setup and then change it to GMT-3:30: switch:admin> tstimezone Time Zone Hour Offset: 0 Time Zone Minute Offset: 0 switch:admin> tstimezone -3, -30 Updating Time Zone configuration...done. System Time Zone change will take effect at next - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 707
Enter number or control-D to quit ?1 System Time Zone change will take effect at next reboot To revert back to the offset format and verify the configuration: switch admin> tstimezone --old 2 switch admin> tsttimezone Time Zone Hour Offset: 2 Time Zone Minute Offset: 0 See Also date Fabric OS - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 708
the number of times to perform this test. The default value is 1. -ports itemlist Specifies a list of blade ports to test. By default, all the blade ports in the specified slot are tested. Refer to the itemList command help page for more information. Examples To execute this test: switch:admin - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 709
in minutes. The output format adjusts accordingly. Operands none Examples To display the length of time the system has been operational: switch:admin> uptime 12:03am up 4:56, 3 users, load average: 1.17, 1.08, 1.08 See Also date, fastboot, reboot Fabric OS Command Reference 683 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 710
if this port becomes part of a valid path in the future. If a static route requires hardware resources that are already used, a platform conflict warning message is displayed and the configuration does not take effect. When using static routes, load sharing may be affected. The switch attempts to - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 711
a previously configured static route. After this command is issued, the route to domain for in_area might change to use a different output port, but only from port 1 and addressed to domain 2: switch:admin> urouteremove 1 2 done. See Also configShow, dlsShow, uRouteConfig, uRouteShow Fabric OS - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 712
number of local switch. In Port Port from which a frame is received. Except for the cases in which you perform a port swap or enable extended-edge PID (PID Format 2) on a switch, the value is equal to the Area field displayed by the switchShow command. Refer to Fabric OS Administrator's Guide - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 713
the routing information of port 11 to domain 4 only: switch:admin> urouteshow 1/11, 4 Local Domain ID: 3 In Port Domain Out Port Metric Hops Flags Next (Dom, Port) 11 4 16 500 1 D 4,16 See Also portRouteShow, topologyShow, uRouteConfig, uRouteRemove Fabric OS Command Reference 687 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 714
:admin> usbstorage -e USB storage enabled To list the contents of the attached USB device: switch:admin> usbstorage -l firmwarekey\ 0B support\ 106MB support1034\ 105MB config\ 0B 2007 Aug 15 15:13 2007 Aug 24 05:36 2007 Aug 23 06:11 2007 Aug 15 15:13 688 Fabric OS Command Reference 53 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 715
74% To remove an application area: switch:admin> usbstorage -r firmware FW_v6.0.0 To disable an attached USB device: switch:admin> usbstorage -d USB storage disabled supportSave, firmwareDownload, configUpload, configDownload, firmwareKeyupdate Fabric OS Command Reference 689 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 716
functions. Notes The userConfig command operates on the switch-local user database only, regardless of whether the switch is configured to use RADIUS authentication or not. The account database supports a maximum of 256 customer created accounts. 690 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 717
userConfig 2 The backup account database is no longer supported on switches running Fabric OS v6.0 or later. As a consequence, account recovery from backup as well as backup display option (former --show -b option) are no longer supported in Fabric OS v6.0 or later. The execution of this command - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 718
permissions of the account that runs the userConfig --delete command. --addad --deletead Adds one or more ADs to a user account or deletes ADs from a user account. The following operands are supported: username Specifies the account login name. 692 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 719
AD is deleted, the new home AD is set to the lowest numbered AD in the user's AD permissions. The existing AD permission for username, and the AD_ID_list switch:admin> userconfig --show joe Account name: joe Role: admin Description: Joe Smith Enabled: Yes Password Last Change Date: Unknown Password - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 720
See Also To add AD 0 & 255 to bob's AD member list. Home AD is unchanged: switch:admin> userConfig --addad bob -a 0,AD255 To delete AD 128 from bob's AD member list. New home AD is set to 0: switch:admin> userConfig --deletead bob -a 128 -h 0 none 694 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 721
are case-sensitive. old_username Specifies the current user login name. new_username Specifies thee new user login name. Examples To rename the admin-level login name from "USERID" to "admin": switch:admin> userrename USERID admin See Also none Fabric OS Command Reference 695 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 722
in the time period between firmwareDownload and the next reboot, the dates can differ. Operands none Examples To display the firmware version information in a switch: switch:admin> version Kernel: 2.6.14.2 Fabric OS: v6.1.0 Made on: Wed Feb 13 06:59:17 2008 Flash: Thu Feb 14 18:38:31 2008 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 723
to display or change the WWN associated with a switch and to display the switch serial number. All switches have a numeric address that is the unique Fibre Channel address used for communicating with the switch. Alternately, use switchShow to display the switch WWN. A WWN must have eight colon - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 724
2 wwn See Also To display the switch WWN and serial number: switch:admin:admin> wwn -sn WWN: 10:00:00:05:1e:01:23:e0 SN: RC030000089 switchShow 698 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 725
-switch traffic by provisioning certain E_Ports to carry only traffic flowing from a specific set of source ports. The provision (a.k.a TI Zone) is part of the defined zone configuration and does not appear in the effective zone configuration. A Maximum of 255 TI Zones can be created in one fabric - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 726
redirect zones exist. Use zoneDelete to remove the base RD zone, "red_______base". Use cfgDelete to remove the RD zone configuration "r_e_d_i_r_c__fg." TI zones are not supported in fabrics involving switches running firmware versions preceding Fabric OS v6.0. However, the existence of a TI Zone - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 727
--validate Lists all zone members that are not part of the current zone enforcement table. If a zone. mode Specifies the zone database location. Supported mode flag values are: 0 Uses the to existing TI zones. The remove option removes port list members from existing zones. Removal of the - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 728
by default, with failover enabled, and the zone will be activated. This operand is supported only ISL, the alternative ISL is not used and the switch generates a SCN/RSCN to indicate that no ISL the Backbone fabric specify "Port WWN" in portlist to indicate devices talking across fabrics. -- - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 729
across a Fibre Channel router (FCR). Specify FCR to support FCR. Specify nonFCR if you do not wish to support FCR. --rddelete Deletes the RD Zone specified by name. RD Zones are unique in that the zone name is not user-defined. It is derived based on members and the specified configuration. Use - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 730
-f You are about to prune the zone configurations, based on zone --validate output. Do you want to prune the zone configurations (yes, y, no, n): [no] y 2. Traffic isolation zone commands: To create a traffic isolation zone with failover enabled (default). switch:admin>zone --create -t ti red_zone - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 731
defined configuration: switch:admin>zone --show blue_zone Zone Name: blue_zone: List of port: 1,2; 1,3; 3,3; 4,5 Failover: Enabled Status: Activated To create an FCR TI Zone within an Edge fabric where a host should to talk to target1 and target4 through port number 2 on an Edge fabric switch with - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 732
40:40:40:40:40:40:40:40 restartable noFCR This command creates the following zone objects: 4. RD zone "red_0917_10_10_10_10_10_10_10_10_20_20_20_20_20_20_20_20", with a restrictedly policy and no FCR support. 5. The base zone object, "red_______base". 6. The RD zone configuration, "r_e_d_i_r_c__fg - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 733
memory with the cfgSave command. For the change to become effective, enable the configuration with the cfgEnable command. Note When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands The following operands are required: "zoneName" Specify the name of - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 734
". Only one "broadcast" zone can exist within a fabric. This type of zone is enforced by the hardware; the switch controls the data transfer to a port. This command changes the defined configuration. For the change to be preserved across switch reboots, save it to nonvolatile memory with the cfgSave - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 735
using a combination of port numbers and zone aliases: sw5:admin> zonecreate "Purple_zone", "1,0; loop1" sw5:admin> zonecreate "Blue_zone", "1,1; array1; 1,2; array2" sw5:admin> zonecreate "Green_zone", "1,0; loop1; 1,2; array2" zoneAdd, zoneDelete, zoneRemove, zoneShow Fabric OS Command Reference - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 736
, enable the configuration with the cfgEnable command. Notes When FCS policy is enabled, this command can be issued only from the primary FCS switch. the zone "Blue_zone": switch:admin> zonedelete "Blue_zone" See Also zoneAdd, zoneCreate, zoneRemove, zoneShow 710 Fabric OS Command Reference 53- - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 737
help information: switch:admin> zonehelp configuration information Add a member to a configuration Clear all zone configurations Create a zone configuration Delete a zone configuration Disable a zone configuration Enable a zone configuration Configure Fabric OS Command Reference 711 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 738
enable the configuration with the cfgEnable command. Note When FCS policy is enabled, this command can be issued only from the primary FCS switch marks are optional. A zone configuration name must begin with a letter followed by any number of letters, numbers, and underscores. Names are case - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 739
become effective, enable the configuration with the cfgEnable command. Note When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands , cfgEnable, cfgRemove, cfgSave, cfgShow, zoneObjectCopy, zoneObjectRename Fabric OS Command Reference 713 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 740
with the cfgSave command. For the change to become effective, enable the configuration must be enabled with the cfgEnable command. Note When FCS policy is enabled, this command can be issued only from the primary FCS switch. Operands The following operands are required: "objectName" The name of - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 741
Use switchShow for a list of valid port area or index numbers. • A World Wide Name • A zone alias name Examples To remove "array2" from "Blue_zone": switch:admin> zoneremove "Blue_zone", "array2" See Also zoneAdd, zoneCreate, zoneDelete, zoneShow Fabric OS Command Reference 715 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 742
is specified, it is used as a pattern to match zone configuration names, and those that match in the defined configuration are displayed. Notes When FCS policy is enabled, this command can be issued on any FCS switch in the fabric. Operands This command has the following operands: "pattern - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 743
on the primary Fabric Configuration Server (FCS) when FCS policy is enabled. Primary FCS commands switch. Must be run from the primary FCS switch. Must be run from the primary FCS switch. Must be run from the primary FCS switch. Can be run on all FCS switches. Must be run from the primary FCS switch - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 744
. Must be run from the primary FCS switch. Must be run from the primary FCS switch. Must be run from the primary FCS switch. Must be run from the primary FCS switch. Must be run from the primary FCS switch. Must be run from the primary FCS switch. 718 Fabric OS Command Reference 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 745
POST. This comand does not reboot the switch from standby. firmwareCommit Commits the firmware to nonvolatile memory. firmwareDownload Downloads the firmware onto switch. firmwareDownloadStatus Displays the progress and status of a firmware download. firmwareKeyShow Displays the keys used to - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 746
interface. (UNIX command. No Fabric OS help page.) ping6 Displays the link operating mode for a network interface. (Linnux command. No FOS help page.) reboot Reboots the standby CP. setModem Enables or disables modem dial-in to a control processor (CP). Not supported on the Brocade DCX - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 747
is part of the current AD. • AD0Disallowed = Allowed to execute only in AD255 and AD0 (if no ADs are configured). • AD0Only = Allowed to execute only in AD0 when ADs are not configured. 4. Command-specific: checks whether the command is supported on the platform for which it is targeted. Fabric OS - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 748
types Refer to Table 1 for the RBAC and Admin Domain availability of all Fabric OS commands. TABLE 1 RBAC availability and admin domain type Command Name User Admin Operator Switch Admin aaaConfig ad ag agShow aliAdd aliCreate aliDelete aliRemove aliShow aptPolicy auditCfg authUtil bannerSet - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 749
domain type Command Name User Admin Operator Switch Admin cfgDisable O cfgEnable configShow N configUpload N configure N dataTypeShow O date OM OM OM OM N N N O O O O O O O O N N N OM N N N O N N N N Fabric Admin OM OM OM OM OM OM OM OM OM OM OM OM OM O O O O O O O O OM OM OM OM OM - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 750
admin domain type Command Name User Admin Operator Switch Admin diagShow diagSkipTest diagStopBurnin OM OM OM O OM OM OM Zone Admin N N N N N N N N N O O O O O O O N O N N N N N N N O O N O N O O N N Fabric Admin OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 751
domain type Command Name User Admin Operator Switch Admin fcpLogEnable fcpLogShow fcpProbeShow OM OM OM OM OM OM OM OM OM Zone Admin N N N N O N O O O O N O O O O O O O N O O N N N O N N O O O O O O O Fabric Admin OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 752
admin domain type Command Name User Admin Operator Switch Admin foscConfig fruReplace fspfShow OM O OM O OM O OM Zone Admin O N O N N N N N N O N N N N N N N OM N N N N N N N OM N N N N OM O N N Fabric Admin OM OM OM OM OM OM OM OM OM O OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 753
and admin domain type Command Name User Admin Operator Switch Admin interfaceShow interOpMode O OM OM O O O O Zone Admin O O N N N N N N O O N O N O N O O O N O N N O O O N O O O OM OM OM O N Fabric Admin OM OM OM OM OM OM OM OM OM OM OM OM OM O OM OM OM OM OM OM OM N OM O OM OM OM - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 754
TABLE 1 RBAC availability and admin domain type Command Name User Admin Operator Switch Admin miniCycle O OM OM OM msCapabilityShow O OM OM N O O O O O O O O O O N O O O O O O O O O N OM N O N N N N N N N N Fabric Admin OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 755
and admin domain type Command Name User Admin Operator Switch Admin perfCfgClear O perfCfgRestore O perfCfgSave OM OM Zone Admin N N N N N O N N N N N O N N N N N O O O N N O N N N N N N N O N N Fabric Admin OM OM OM OM OM O OM OM OM OM OM OM O O O OM OM OM OM OM OM OM OM OM OM OM OM - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 756
admin domain type Command Name User Admin Operator Switch Admin portCfgPersistentEnable O OM OM O OM OM OM O OM OM OM Zone Admin N N N N N N O N O O O O N O O O O O O O O O O O O O O O N N N N O O Fabric Admin OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 757
type Command Name User Admin Operator Switch Admin portStats64Show portStatsClear O O N N N O O N N N N N OM N N N N N N N N N N N N Fabric Admin OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM O OM N O OM OM OM OM OM OM OM OM OM OM OM OM OM OM OM Basic Switch Admin O O O OM OM OM OM O O OM OM - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 758
availability and admin domain type Command Name User Admin Operator Switch Admin sensorShow O setDbg O setModem O OM OM OM Zone Admin N N N N N N N N N N N N N N N N O O O O O O O O O O N N O O O O N Fabric Admin OM OM OM OM OM OM OM OM OM OM OM OM OM O OM OM OM OM OM OM OM OM OM OM OM - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 759
admin domain type Command Name User Admin Operator Switch Admin switchStatusPolicyShow O switchStatusShow O N version O OM OM OM Zone Admin N N O O O O O O O N N N N O N O O N N N N N N O O O N OM N N O Fabric Admin OM OM OM OM OM OM OM OM OM OM OM OM OM OM N OM OM OM OM OM OM OM O OM - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 760
RBAC availability and admin domain type Command Name User Admin Operator Switch Admin wwn O OM OM OM zone zoneAdd O OM O O Zone Admin O OM OM OM OM O OM OM OM OM OM Fabric Admin OM OM OM OM OM O OM OM OM OM OM Basic Switch Admin O O O O O O O O O O O Security Admin Domain Admin OM - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 761
chassisConfig, 72 clock server, 677, 678 command line interface, 1 commands supported on the active CP, 719 commands supported on the standby CP, 719 Condor-based platform, 456, 505 configDefault, 78 configure, 91 Control Processor, 721 and RBAC, 721 Fabric OS Command Reference 735 53-1000599-02 - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 762
default service, 119 dual CP system active CP and supportFTP, 625 dynamic load sharing, 37, 116, 117, 118, 685 E E_D_TOV and configDownload, 81 and configure 685 fabric log, 132 Fabric OS Command Line Interface, 2, 722 fabric parameter, 445, 447, 472, 474 fabric port information, 128, 130 Fabric Watch - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 763
Fibre Channel Extended Link Service, 152, 499, 539 Fibre Channel Protocol, 158, 159 FICON, 98, 191, 192, 194, 196, 197, 200, 202, 459, 608, 609, 629, 631, 632, 633, 644 FICON-MIB, 608, 609 FICON-TRAP, 609 field replaceable unit, see FRU filter-based monitor, 395, 402, 403, 404, 408 firmware download - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 764
, 78 Extended Fabrics, 92, 451, 452 Fabric Watch, 72, password and login, 332 and SNMPv3, 608 and supportFTP, 623 and supportSave, 625 expiration policy, 377 password port configuration, 72, 92, 424, 443, 445, 464, 472, 473 port ID, 93, 152, 174, 178, 184, 371, 445, 447, 456, 472, 474, 515, 642 port - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 765
341, 342, 343, 505 serial port, 127, 320, 333, 356, switch configuration, 80, 87 switch model, 91, 263, 642 switch name, 81, 123, 126, 165, 570, 571, 573, 581, 641 switch speed, 637 switchBeacon, 634 switchShow, 644 SW-TRAP, 609 syslog, 122, 655, 656, 659 sysShutdown active CP, 660 system services - HP StorageWorks 8/80 | Brocade Fabric OS Command Reference Guide v6.1.0 (53-1000 - Page 766
, 72, 377, 690 user port, 318, 424, 484, 515 V VC_RDY, 452 VEX_Port, 472, 473, 474 virtual channel settings, 92, 93 W WAN_TOV, 81, 91, 92 Web Tools, 268, 406 Z zone, 699 zone configuration and cfgActvShow, 55 and zone, 699 clearing, 57 inaliShow, 36 zoneObjectRename, 714 740 Fabric OS Command
53-1000599-02
12 March 2008
Fabric OS
Command Reference Manual
Supporting Fabric OS 6.1.0