-TE This document is an addendum for Fabric OS users to supplement the Fabric OS version 3.x documentation set. This document is specific to Fabric OS version 3.x and all switches running Fabric OS version 3.x, including the HP StorageWorks SAN Switch 2/8 EL, SAN Switch 2/16, and MSA SAN Switch 2/8. - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 2
Development Company, L.P. © Copyright 2004 Brocade Communications Systems, Incorporated. Hewlett-Packard HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 3
documentation 10 Conventions 11 Document conventions 11 Text symbols 11 Getting help 12 HP technical support 12 HP storage web site 12 HP authorized reseller 12 1 Advanced performance monitor user guide 13 ISL Monitoring 13 Using ISL Monitoring 14 Displaying ISL Monitors 14 Clearing - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 4
an Account Password 136 Setting Up RADIUS AAA Service 137 Considerations for RADIUS Use 138 Accounting Support 139 Setting Up the RADIUS Server 139 Windows 2000 139 Linux 141 Setting Up the Switch 142 Configuring for SNMP 145 Configuring for SNMPv1 146 7 ISL trunking user guide 151 Long - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 5
Contents 8 Fabric OS reference guide 153 aaaconfig 155 agtcfgshow 157 authutil 159 configdownload 161 configure zoneobjectcopy 233 zoneobjectexpunge 234 zoneobjectrename 236 9 Fabric Watch User Guide 239 Fabric Watch Reports 239 Switch Health Report 239 Fabric Watch Message Formats 239 - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 6
16 Configure (Upload/Download) Tab 42 17 Routing (FSPF Route) Tab 44 18 Routing (Static Route) Tab 45 19 Routing (Link Cost) Tab 46 20 Extended Fabric Tab 47 21 AAA Service View Example 64 29 Alias Tab 67 30 Zone Tab 68 31 Fabric Assist Tab 69 32 Config Tab 70 33 Switch Health Report - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 7
2 Supported platforms 18 3 Firmware field descriptions 29 4 Configure (Upload/Download) Field Descriptions 43 5 AAA Service Tab Limitations 74 12 Access Defaults 133 13 Switch Fabric Settings 165 14 Virtual Channel Settings 168 15 Zoning Operation Parameter 169 16 RSCN Transmission Mode 169 - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 8
Contents 8 Fabric OS 3.x Document Addendum - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 9
About this Guide ■ HP StorageWorks SAN Switch 2/8 EL ■ HP StorageWorks SAN Switch 2/16 ■ HP StorageWorks MSA SAN Switch 2/8 For example, this document provides important technical updates to the following documents: ■ HP StorageWorks Advanced Performance Monitor Version 3.1.x/4.1.x User Guide, part - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 10
product, for example SAN Switch 2/16, SAN Switch 2/8 EL, or MSA SAN Switch 2/8 models. The switch overview page displays. 5. Go to the Product information section, located on the far right side of the web page. 6. Click Technical documents. 7. Follow the on-screen instructions to download the - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 11
, italic font Blue underlined sans serif font text: http://www.hp.com Element Cross-reference links User input, commands, code, file and directory names, and system responses (output and messages) Variables web site addresses Text symbols The following symbols may be found in the text of this guide - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 12
still have a question after reading this guide, contact an HP authorized service provider or access our web site: http://www.hp.com. HP technical support Telephone numbers for worldwide technical support are listed on the following HP web site: http://www.hp.com/support/. From this web site, select - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 13
monitor user guide 1 This chapter contains updates to the HP StorageWorks Advance Performance Monitor Version 3.1.x/4.1.x User Guide, part Telnet Commands," add the following: ISL Monitoring Note: ISL monitoring is supported only in Fabric OS v3.2.x. ISL monitoring measures the outbound traffic - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 14
port goes offline. ISL monitoring is enabled by default, except when using HP Fabric Manager, for which ISL monitoring must be enabled on a per-switch basis. For more information, refer to the HP StorageWorks Fabric Manager User Guide. You can display existing ISL monitors using the perfMonitorShow - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 15
Advanced performance monitor user guide Clearing ISL Monitors Use the perfMonitorClear command to clear ISL monitor counters. The following example clears statistical counters for an ISL monitor. switch:admin> perfmonitorclear "ISL", 0 This will clear ISL monitor on port 0, continue? (yes, y, no, - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 16
Advanced performance monitor user guide 16 Fabric OS 3.x Document Addendum - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 17
Advanced Web Tools user guide 2 This chapter contains updates to the HP StorageWorks Web Tools Version 3.1.x/4.1.x User Guide, part number AA- manually refresh the status of a switch within the fabric by right-clicking the name of that switch in the Fabric Tree and selecting Refresh. The Switch - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 18
Advanced Web Tools user guide On original Table 2: Supported platforms Operating system RedHat Linux® 9.0 Solaris 2.8 Solaris 2.9 Windows® 2000 Windows 2003 as follows: ■ 128 MB or more RAM for fabrics comprising 10 switches or fewer ■ 256 MB or more RAM for fabrics comprising 15 switches or fewer ■ - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 19
user guide On original page 38, replace the entire "Installing a Web Browser" section with the following: If not already installed, install one of the following browsers: ■ Internet Explorer 6.0 ■ Mozilla 1.6 For instructions with Internet Explorer or Mozilla (supported on Solaris only). Configuring - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 20
Advanced Web Tools user guide On original page 40, replace the following text: Installing the Java Plug-in on Windows XP, 2000, or NT To determine the version of the Java Plug-in installed on Windows XP, NT, or 2000, and install if necessary: With the this text: Installing the Java Plug-in on - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 21
Advanced Web Tools user guide On original page 65, under the heading "Switch Status Example," replace original Figure 13, "Switch status window," with the following: Figure 2: Switch status window On original page 66, under the heading "Using the Switch Status Button," add the following at the end - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 22
Advanced Web Tools user guide Figure 3: Switch status window, port detail 22 Fabric OS 3.x Document Addendum - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 23
Tools user guide On original page 67, under the heading "Switch Events Example," replace original Figure 14, "Switch events window," with the following: Figure 4: Switch events window On original page 67, under the heading "About the Switch Events Button," add the following: Filtering Switch Events - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 24
Web Tools user guide Figure 5: Event filter dialog box Filtering Events by Time Intervals To filter events by time intervals: 1. Launch Web Tools. 2. Select the desired switch from the Fabric Tree. The Switch View opens. 3. Select the Switch Events button from the Switch View. A Switch Events - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 25
Advanced Web Tools user guide 3. Select the Switch Events button from the Switch View. A Switch Events Report appears Switch Admin Window Field Descriptions," modify original Table 17, "Switch Admin Window Field Descriptions," as follows. Delete the following row: Reset Click this button to reset - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 26
Advanced Web Tools user guide On original page 95, under the heading "Switch Information Tab Example," replace original Figure 18, "Switch Information Tab," with the following: Figure 6: Switch Information Tab 26 Fabric OS 3.x Document Addendum - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 27
Advanced Web Tools user guide On original page 99, under the heading "Network Config Tab Example," replace original Figure 19, "Network Configuration Tab," with the following: Figure 7: Network Configuration Tab - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 28
Advanced Web Tools user guide On original pages 103 through 105, replace the entire section, "About the Upload/Download Tab," with the following: About the Firmware Tab Use the Firmware tab to complete tasks such as: ■ Downloading firmware ■ Returning the switch to the original configuration ■ - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 29
Web Tools user guide Firmware Field Descriptions The Firmware fields are described in Table 3. Table 3: Firmware field descriptions Field Firmware Version Firmware download Firmware download and Fastboot Protocol Host IP File Name User Name Password Fastboot Reboot Firmware Download Progress - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 30
Click Fastboot. 5. Click Apply. Performing a Reboot To perform a reboot of a switch: 1. Access the Switch Admin Window (see "About the Switch Admin Window"). 2. Enter the admin user name and password. 3. Select the Firmware tab. 4. Click Reboot. 5. Click Apply. 30 Fabric OS 3.x Document Addendum - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 31
Advanced Web Tools user guide On original page 109, under the heading "SNMP Tab Example," replace original Figure 22, "SNMP information. Delete the following row: Trap Level Use to set the severity level of switch events that prompt SNMP traps. Default is 0. Fabric OS 3.x Document Addendum 31 - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 32
Advanced Web Tools user guide Delete the following both viewed and make changes. Use to set the severity level of switch events that prompt SNMP traps. Default is 0. On original page 111, under the heading "Using the SNMP See "About the Switch Events Button." 32 Fabric OS 3.x Document Addendum - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 33
Advanced Web Tools user guide On original page 112, under the heading "License Admin Tab Example," replace original Figure 23, "License Admin Tab," with the following: Figure 10: License Admin - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 34
Advanced Web Tools user guide On original page 114, under the heading "Add a License to a Switch," delete the following steps 4 and License button. On original page 114, under the heading "Remove a License From a Switch," replace step 4: 4. Enter the license key to remove, or double-click a license - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 35
Advanced Web Tools user guide On original page 116, under the heading "Port Settings Tab Example," replace original Figure 24, "Port Setting Tab," with the following: Figure 11: Port Setting - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 36
Advanced Web Tools user guide On original page 119, under the heading "Disabling a Port over Reboots," Parameters, Virtual Channel parameters, Arbitrated Loop parameters, and System Services parameters, and to back up and download the switch configuration file. 36 Fabric OS 3.x Document Addendum - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 37
Advanced Web Tools user guide On original page 121, under the heading "Configure (Fabric) Tab Example," replace original Figure 25, "Configure (Fabric) Tab," with the following: Figure 12: Configure (Fabric) Tab Fabric OS 3.x Document Addendum 37 - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 38
format that is compatible with Fibre Channel Storage Switch 8 and Fibre Channel Storage Switch 16. ■ Format 0 (16-port encoding) - Native format ■ Format 1 (0-base, 256-port encoding) - Core PID format ■ Format 2 (16-base, 256-port encoding) - Extended-edge PID format Delete the following row: VC - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 39
Advanced Web Tools user guide On original page 124, under the heading "Configure (Virtual Channel) Tab Example," replace original Figure 26, "Configure (Virtual Channel) Tab," with the following: Figure 13: Configure (Virtual Channel) Tab Fabric OS 3.x Document Addendum 39 - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 40
Advanced Web Tools user guide On original page 126, under the heading "Configure (Arbitrated Loop) Tab Example," replace original Figure 27, "Configure (Arbitrated Loop) Tab," with the following: Figure 14: Configure (Arbitrated Loop) Tab 40 Fabric OS 3.x Document Addendum - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 41
Advanced Web Tools user guide On original page 128, under the heading "Configure (System) Tab Example," replace original Figure 28, "Configure (System) Tab," with the following: Figure 15: Configure (System) Tab Fabric OS 3.x Document Addendum 41 - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 42
Advanced Web Tools user guide On original page 129, after the section "Configure (System) Field Descriptions," add the following sections: Configure (Upload/Download) Tab Example An example of the Configure (Upload/Download) Tab is shown in Figure 16. Figure 16: Configure (Upload/Download) Tab - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 43
the following sections: Backing Up a Switch Config File To back up a firmware configuration file: 1. Access the Switch Admin Window (see "About the Switch Admin Window.") 2. Enter the admin user name and password. 3. Select the Switch Information tab. 4. Disable the switch. 5. Click the Apply button - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 44
Advanced Web Tools user guide 7. Select the Upload/Download subtab. 8. Select the Config Download to Switch radio button. 9. Enter the User Name, Password, and Host IP information. 10. Enter the name of the config file with a fully qualified path. 11. Click Apply. You can monitor the progress by - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 45
Advanced Web Tools user guide On original page 135, under the heading "Routing (Static Route) Tab Example," replace original Figure 30, "Routing (Static Route) Tab," with the following: Figure 18: Routing (Static Route) Tab Fabric OS 3.x Document Addendum 45 - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 46
Advanced Web Tools user guide On original page 137, under the heading "Routing (Link Cost) Tab Example," replace original Figure 31, "Routing (Link following text to the end of step 6: Setting the value to 0 sets the link cost to the default value for that port. 46 Fabric OS 3.x Document Addendum - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 47
Advanced Web Tools user guide On original page 143, replace the section "Extended Fabrics Tab Example" with the following: Extended Fabric Tab Example An example of the Extended Fabric tab - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 48
Advanced Web Tools user guide In original Table 33, "Extended Fabric Field Descriptions," delete the following rows: Enable Disable Extended Fabric Mode Click the radio button to enable the Extended Fabric mode. The switch must be disabled to enable the Extended Fabric mode. Click to disable the - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 49
Advanced Web Tools user guide On original page 145, after the section "Using the Extended Fabric Tab to Configure a Port For Long-Distance," add the following sections: About the AAA Service Tab Use the AAA Service tab to manage the RADIUS server. Through the AAA Service tab, you can perform the - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 50
in as admin to configure the RADIUS server. To configure the RADIUS server: 1. Access the Switch Admin Window (see "About the Switch Admin Module.") 2. Enter the admin user name and password. 3. Select the AAA Service tab. 4. Click Add. You can configure up to five RADIUS servers. If five RADIUS - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 51
Tools user guide The . 10. Optional: Select an authentication protocol from CHAP or PAP. The default value is CHAP; if you do not change it, CHAP will be Access the Switch Admin Window (see "About the Switch Admin Module.") 2. Enter the admin user name and password. 3. Select the AAA Service tab. - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 52
Advanced Web Tools user guide Removing a RADIUS Server To remove a RADIUS server: 1. Access the Switch Admin Window (see "About the Switch Admin Module.") 2. Enter the admin user name and password. 3. Select the AAA Service tab. 4. Select a RADIUS server from the RADIUS Configuration list. 5. Click - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 53
Advanced Web Tools user guide On original page 174, replace original Figure 41, "Alarm Notification Tab of Fabric Watch," with the following: Figure 23: Alarm Notification Tab On original page - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 54
Advanced Web Tools user guide On original page 177, delete the section "About the Threshold Configuration Tab." On original page 177, in the section "Threshold Configuration Tab Example," replace the - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 55
Advanced Web Tools user guide On original pages 177 and 178, add the following table after original Figure 42, the threshold boundary buffer size of the selected area. Selects either System Default or Custom Defined to indicate which traits are to be activated. Fabric OS 3.x Document Addendum 55 - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 56
user guide Alarm Configuration Tab Table 8 lists and describes the components of the Alarm Configuration tab. Table 8: Alarm Configuration Components Component System Default , and Email to be active on the switch side. Select either System Default or Custom Defined to indicate which traits are - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 57
Advanced Web Tools user guide On original page 181, under the heading "Configuring Boundary and Alarm Settings," you do not need to finish the steps in this procedure. If you want to change the system default settings, proceed to the next step. 6. Enter custom values in the trait fields (such as Unit - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 58
Advanced Web Tools user guide On original page 184, replace original Table 45, "Email Configuration : The Fabric Events window provides a running log of events for all switches in the fabric. Events are displayed for all switches in the fabric in the Fabric Events window. Fabric events can be - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 59
Advanced Web Tools user guide On original page 190, under the heading "Fabric Events Example," replace original Figure 45, "The Fabric Events Window," with the following: Figure 26: The Fabric - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 60
Advanced Web Tools user guide 5. Optional: To filter events within a certain time period: a. Click From and enter the start time and date in the fields. b. Click To and enter the - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 61
Advanced Web Tools user guide On original page 195, under the heading "Name Server Example," replace original Figure 47, "Name Server Table Window," with the following: Figure 27: Name Server - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 62
Tools user guide On Fibre Channel FC4 layer types supported by the device, such as IP or FCP. Displays the Fibre Channel classes of service supported by the device. Displays Name Server information for a particular device: 1. Access the Switch Explorer view. 2. Select the Name Server icon in the - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 63
has a Zoning license installed but is not the primary switch, the Zone Admin icon is displayed in the Fabric Toolbar but not activated. For specific information regarding secure fabrics, refer to the HP StorageWorks Secure Fabric OS Version 1.0 User Guide. When you click the Zone Admin icon from the - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 64
Advanced Web Tools user guide In the Zone Admin module module is identified in the top right corner. This information is updated only when you manually refresh the Zone Admin contents by clicking the Refresh icon at the bottom right corner corner is not updated. 64 Fabric OS 3.x Document Addendum - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 65
Advanced Web Tools user guide Caution: Clicking the Refresh icon in the lower right corner zone is enabled, a message is displayed, indicating that there is no active zoning configuration on the switch. On original page 208, in the section "Adding a WWN in the Zoning Database," replace the - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 66
Advanced Web Tools user guide On original page 209, in the section "Replacing a WWN in the Zoning Database," replace the following heading: Replacing a WWN in the Zoning Database With this - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 67
Advanced Web Tools user guide On original page 217, under the heading "Alias Tab Example," replace original Figure 51, "Alias Tab in the Zone Administration Window," with the following: Figure - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 68
Advanced Web Tools user guide On original page 223, under the heading "Zone Tab Example," replace original Figure 52, "Zone Tab in the Zone Administration Window," with the following: Figure - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 69
Advanced Web Tools user guide On original pages 232 and 233, under the heading "Deleting an QuickLoop," in step 5, replace the following text: The selected QuickLoop is deleted from the - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 70
Advanced Web Tools user guide On original page 238, under the heading "Deleting an Fabric Assist Zone," in step 5, replace the Tab Example," replace original Figure 55, "Config Tab in the Zone Administration Window," with the following: Figure 32: Config Tab 70 Fabric OS 3.x Document Addendum - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 71
Advanced Web Tools user guide On original page 246, after the section "Creating a Configuration Analysis Report," add the following section: Displaying an Initiator/Target Accessibility 1. Access the Zone Administration window. - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 72
Advanced Web Tools user guide 72 Fabric OS 3.x Document Addendum - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 73
3 This chapter contains updates to the HP StorageWorks Zoning Version 3.1.x/4.1.x User Guide, part number AA-RS26C-TE. On original page 17, under the heading "License Activation Using Web Tools," replace the following text: 6. Enter the license key - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 74
Zoning version user guide On page 30, under the heading "Detailed Zone Configuration Procedures," 4.4.0 Maximum Database Size (KB) 64 64 96 128 96 256 128 256 Note: Zoning databases larger than 96 KB are not supported on SAN Switch 2/8 EL and SAN Switch 2/16 with 16 MB of memory. 74 Fabric OS - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 75
Diagnostic and system error messages reference guide 4 This chapter contains updates to the HP StorageWorks Diagnostic and System Error Messages Version 3.1.x Reference Guide, part number AA-RUPZA-TE. The following modules report new (AUTH and SEC) or modified messages in Fabric OS v3.2.x: ■ AUTH - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 76
Diagnostic and system error messages reference guide AUTH-AUTHCFGCHANGE Message INFO AUTH- problem is transient. Retry the command. If the command fails consistently, copy the message, collect switch information using the supportshow command, and contact your switch service - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 77
problem is transient. Reinitialize authentication by issuing switchdisable and switchenable commands or the portdisable and portenable commands. If the command fails consistently, copy the message, collect switch information using the supportshow command, and contact your switch service provider - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 78
system error messages reference guide AUTH-AUTHERROR Message is rejected because the other side does not support authentication or a required protocol. ■ Internal error switch. ■ Failed to get security license. ■ Failed to validate switch or port name. ■ Disabled port due to unauthorized switch - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 79
the problem is Switch PID format changed to Format 2 ('Extended Edge PID Format'). Probable Cause The PID format for the fabric was changed to Format 2, extended-edge PID. For more information on PID format, refer to the HP StorageWorks Fabric OS Procedures Version 3.1.x/4.1.x User Guide - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 80
Diagnostic and system error messages reference guide DIAG-BADINT Message CRITICAL DIAG-BADINT, 1, , Action For the HP StorageWorks SAN Switch 2/16, replace the motherboard FRU. For the HP StorageWorks SAN Switch 2/8 EL, replace the entire switch. Severity CRITICAL DIAG - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 81
Diagnostic and system error messages reference guide DIAG-CAMFLTR Message CRITICAL DIAG-CAMFLTR, 1, - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 82
error messages reference guide This can be caused by a faulty cable or deteriorated SFP. It can also indicate more serious problems in the motherboard If the problem persists: ■ For the SAN Switch 2/16, replace the motherboard FRU. ■ For the SAN Switch 2/8 EL, replace the entire switch. Severity - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 83
Diagnostic and system error messages reference guide DIAG-CAMSTAT Message CRITICAL DIAG-CAMSTAT, 1, , pass . Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL, replace the entire switch. Severity CRITICAL DIAG-CLEAR_ERR - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 84
Diagnostic and system error messages reference guide DIAG-CMBISRF Message CRITICAL DIAG-CMBISRF, 1, use only. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL, replace the entire switch. Severity CRITICAL DIAG-CMBISRTO Message < - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 85
guide problem was detected at the wrong port. This usually indicates an ASIC failure. This message is generated by the centralmemorytest command. The error code value is for internal use only. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 86
Diagnostic and system error messages reference guide Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL, replace the entire switch. Severity CRITICAL DIAG-CMICKSUM Message CRITICAL DIAG-CMICKSUM, 1, , pass , Pt< - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 87
Diagnostic and system error messages reference guide DIAG-CMIDATA Message CRITICAL DIAG-CMIDATA, 1, < use only. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL, replace the entire switch. Severity CRITICAL DIAG-CMIINVCAP Message - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 88
Diagnostic and system error messages reference guide DIAG-CMINOCAP Message CRITICAL DIAG-CMINOCAP, 1, use only. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL, replace the entire switch. Severity CRITICAL DIAG-CMISA1 Message < - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 89
Diagnostic and system error messages reference guide DIAG-CMNOBUF Message CRITICAL DIAG-CMNOBUF, 1, - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 90
Diagnostic and system error messages reference guide Severity CRITICAL DIAG-ERRSTAT (2LONG) Message CRITICAL DIAG- necessary. If the problem persists: ■ For the SAN Switch 2/16, replace the motherboard FRU. ■ For the SAN Switch 2/8 EL, replace the entire switch. Severity CRITICAL - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 91
Diagnostic and system error messages reference guide DIAG-ERRSTAT (BADEOF) Message CRITICAL DIAG-ERRSTAT (BADEOF), 1, . If the problem persists: ■ For the SAN Switch 2/16, replace the motherboard FRU. ■ For the SAN Switch 2/8 EL, replace the entire switch. Severity CRITICAL - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 92
error messages reference guide Recommended Action Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if necessary. If the problem persists: ■ For the SAN Switch 2/16, replace the motherboard FRU. ■ For the SAN Switch 2/8 EL, replace the entire switch. Severity CRITICAL DIAG - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 93
Diagnostic and system error messages reference guide DIAG-ERRSTAT (DISCC3) Message CRITICAL DIAG-ERRSTAT (DISCC3), . If the problem persists: ■ For the SAN Switch 2/16, replace the motherboard FRU. ■ For the SAN Switch 2/8 EL, replace the entire switch. Severity CRITICAL DIAG - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 94
error messages reference guide Recommended Action Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if necessary. If the problem persists: ■ For the SAN Switch 2/16, replace the motherboard FRU. ■ For the SAN Switch 2/8 EL, replace the entire switch. Severity CRITICAL DIAG - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 95
Diagnostic and system error messages reference guide DIAG-ERRSTAT (TRUNC) Message CRITICAL DIAG-ERRSTAT (TRUNC), necessary. If the problem persists: ■ For the SAN Switch 2/16, replace the motherboard FRU. ■ For the SAN Switch 2/8 EL, replace the entire switch. Severity CRITICAL DIAG - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 96
error messages reference guide Recommended Action Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if necessary. If the problem persists: ■ For the SAN Switch 2/16, replace the motherboard FRU. ■ For the SAN Switch 2/8 EL, replace the entire switch. Severity CRITICAL DIAG - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 97
command. The error code value is for internal use only. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL, replace the entire switch. Severity CRITICAL DIAG-LCMEM Message CRITICAL DIAG-LCMEM, 1, , pass , Pt - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 98
Diagnostic and system error messages reference guide DIAG-LCMEMTX Message CRITICAL DIAG-LCMEMTX, 1, use only. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL, replace the entire switch. Severity CRITICAL DIAG-LCMRS Message < - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 99
Severity CRITICAL Diagnostic and system error messages reference guide DIAG-LCMTO Message CRITICAL DIAG-LCMTO, 1, - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 100
Diagnostic and system error messages reference guide Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL, replace the entire switch. Severity CRITICAL DIAG-MEMORY Message CRITICAL DIAG-MEMORY, 1, , Memory Error, Address < - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 101
Diagnostic and system error messages reference guide DIAG-MEMSZ Message CRITICAL DIAG-MEMSZ, 1, , only. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL, replace the entire switch. Severity CRITICAL DIAG-NOSEGMENT - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 102
Diagnostic and system error messages reference guide Severity CRITICAL DIAG-PORTABSENT Message CRITICAL DIAG-PORTABSENT, . If the problem persists: ■ For the SAN Switch 2/16, replace the motherboard FRU. ■ For the SAN Switch 2/8 EL, replace the entire switch. Severity CRITICAL - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 103
error messages reference guide Recommended Action Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if necessary. If the problem persists: ■ For the SAN Switch 2/16, replace the motherboard FRU. ■ For the SAN Switch 2/8 EL, replace the entire switch. Severity CRITICAL DIAG - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 104
or deteriorated SFP. Replace the cable or SFP if necessary. If the problem persists: ■ For the SAN Switch 2/16, replace the motherboard FRU. ■ For the SAN Switch 2/8 EL, replace the entire switch. Severity CRITICAL DIAG-PORTWRONG Message CRITICAL DIAG-PORTWRONG, 1, , pass - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 105
Diagnostic and system error messages reference guide DIAG-POST_SKIPPED Message WARNING DIAG-POST_SKIPPED, 4, only. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL, replace the entire switch. Severity CRITICAL Fabric OS 3.x - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 106
internal use only. Recommended Action Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if necessary. If the problem persists: ■ For the SAN Switch 2/16, replace the motherboard FRU. ■ For the SAN Switch 2/8 EL, replace the entire switch. 106 Fabric OS 3.x Document Addendum - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 107
Severity CRITICAL Diagnostic and system error messages reference guide DIAG-STATS (FRX) Message CRITICAL DIAG-STATS (FRX . If the problem persists: ■ For the SAN Switch 2/16, replace the motherboard FRU. ■ For the SAN Switch 2/8 EL, replace the entire switch. Severity CRITICAL - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 108
Diagnostic and system error messages reference guide DIAG-STATS (FTX) Message CRITICAL DIAG-STATS (FTX), 1, - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 109
Diagnostic and system error messages reference guide Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL, replace the entire switch. Severity CRITICAL DIAG-TBRAM_INC_RWTEST Message CRITICAL DIAG-TBRAM_INC_RWTEST, 1, , pass < - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 110
system error messages reference guide DIAG-TBRAM_WTEST Message < For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL, replace the entire switch. Severity CRITICAL SFP. It can also indicate more serious problems in the motherboard or ASIC. The error code value is - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 111
error messages reference guide Recommended Action Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if necessary. If the problem persists: ■ For the SAN Switch 2/16, replace the motherboard FRU. ■ For the SAN Switch 2/8 EL, replace the entire switch. Severity CRITICAL DIAG - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 112
guide FABRIC-RECONFIG Message INFO FABRIC-RECONFIG, 4, fabric: Probable Cause The fabric has reconfigured due to an offline port. The reason can be one of the following: Fabric Merge Own ID Rcvd Merging two fabrics A subordinate switch went offline. Switch was not able - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 113
messages reference guide D-list conflict The principal switch received a domain list that contains more domains than what the principal switch has already assigned. Recommended Action If the reconfiguration was unplanned, check for problems with the specified port. Some troubleshooting tasks - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 114
Diagnostic and system error messages reference guide SEC-ACCT, Added Message INFO SEC-ACCT, 4, Added account with authorization Probable Cause The specified new account was created. Recommended Action No action is required. Severity INFO SEC-ACCT - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 115
Diagnostic and system error messages reference guide SEC-ACCT, Deleted Message INFO SEC-ACCT, 4, Deleted account Probable Cause An existing account was deleted. Recommended Action No action is required. Severity INFO SEC-ACCT, Recovered Message - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 116
any missing requirements, such as a missing zoning license, RCS capability, or the PID mode on the switch. Refer to the HP StorageWorks Secure Fabric OS Version 1.0 User Guide for more information on secure mode requirements. Severity ERROR SEC-PIDCHGERR, PID Change failed: Change Area failed - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 117
Diagnostic and system error messages reference guide SEC-PIDCHGERR, PID Change failed: Size check failed Message < Message ERROR SEC-PIDCHGERR, 2, Change failed: Switch is busy. Operation failed. Probable Cause The switch security daemon is busy. The status values can be defined - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 118
Change: Success Probable Cause The PID format of the switch was changed either to extended-edge PID or from extended-edge PID. If DCC policies existed, all area ID values either increased or decreased by 16. The values wrap around after a port value of 128. If a DCC policy contains an area of 127 - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 119
Diagnostic and system error messages reference guide SEC-SECCHANGE Message INFO SEC-SECCHANGE, 4, reset. ■ secfcsfailover: The primary FCS has failed over to a new switch. ■ All password changes: A, B, C account passwords were changed. (A, B, C are account names for which passwords - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 120
might be an internal resource issue; rejoin the switch to the fabric and the security data download retries. If the command fails consistently, copy the message, collect switch information using the supportshow command, and contact your switch service provider. Severity WARNING 120 Fabric OS - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 121
■ Low memory ■ Queue full ■ Failure to set password ■ Failure to set SNMP string ■ Failure to sign message ■ Primary FCS downloads security database ■ Nonprimary FCS switch receives security database download Recommended Action This is usually a transient problem. Retry the command that caused the - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 122
Diagnostic and system error messages reference guide SEC-SEC_STATS Message WARNING SEC-SEC_STATS, 3, Security counter fails. Recommended Action If the message is the result of a user command, retry the statistic command. Severity WARNING SEC-SECVIOL_API Message - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 123
Diagnostic and system error messages reference guide SEC-SECVIOL_HTTP Message INFO SEC-SECVIOL_HTTP, 4, Security violation: Unauthorized host with IP address tries to establish HTTP connection. Probable Cause An HTTP - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 124
guide SEC-SECVIOL_DCC Message INFO SEC-SECVIOL_DCC, 4, Security violation: Unauthorized device tries to flogin to port of switch Cause A login security violation was reported. An incorrect password was used while trying to log in through a console - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 125
Diagnostic and system error messages reference guide SEC-SECVIOL_MSaccess Message INFO SEC-SECVIOL_MSaccess, 4, Security violation , 4, Security violation: MS command is forwarded from non primary FCS switch. Probable Cause An MS forward security violation was reported. A management - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 126
guide SEC-SECVIOL_MSop Message INFO SEC-SECVIOL_MSop, 4, Security violation: MS device operates on non primary FCS switch . A management server device is operating on a nonprimary FCS switch. Recommended Action Check the management server policy and verify that the - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 127
and system error messages reference guide SEC-SECVIOL_SCC Message INFO SEC-SECVIOL_SCC, 4, Security violation: Unauthorized switch tries to join secure fabric. Probable Cause An SCC security violation was reported. The specified unauthorized switch attempts to join the - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 128
Diagnostic and system error messages reference guide SEC-SECVIOL_WSNMP Message INFO SEC-SECVIOL_WSNMP, 4, Security violation: Unauthorized host with IP fabric. Take appropriate action as defined by your enterprise security policy. Severity INFO 128 Fabric OS 3.x Document Addendum - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 129
5 This chapter contains updates to the HP StorageWorks Extended Fabric Version 3.1.x/4.1.x User Guide, part number AA-RTSDC-TE. On page 26, under the heading "VC Translation Mode," replace the following text: VC_Translation_Link_Init Specify 1 to activate long distance link - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 130
Extended fabric user guide 130 Fabric OS 3.x Document Addendum - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 131
Fabric OS, refer to the HP StorageWorks Secure Fabric OS Version 1.0 User Guide. Ensuring Network Security To ensure security, Fabric OS supports secure shell (SSH) encrypted sessions. SSH encrypts all messages, including the client's transmission of password during login. The SSH package contains - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 132
user guide Note: To maintain a secure network, avoid using telnet or any other unprotected application when you are working on the switch. For example, if you use telnet to connect to a machine and then start an SSH or secure telnet session from that machine to the switch supports System services (yes - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 133
allowed per logical switch is 15. You can change passwords on user-defined accounts as described in "Changing an Account Password." If the track changes feature is enabled, the system keeps track of account names and login attempts. For large enterprises, Fabric OS also supports RADIUS services, as - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 134
user guide ■ userConfig "--show -a" Shows all account information for a logical switch. ■ userConfig "--show -b" Shows all backup account information for a logical switch. HP (:). 3. In response to the prompt, enter a password for the account. Passwords can be from 8 to 40 characters long. They - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 135
user guide 2. Issue the following command: userConfig "--delete name" where name Specifies the account name. You cannot delete the default accounts accounts with lower permission on the logical switch. Accounts with the user role cannot. 1. Connect to the switch and log in as admin. 2. Enter - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 136
than the current account, you are prompted to enter the old password. Setting Up RADIUS AAA Service Fabric OS supports RADIUS authentication, authorization, and accounting service (AAA). When configured for RADIUS, the switch becomes a RADIUS client. In this configuration, authentication records are - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 137
v3.2.x, or earlier, the way a switch authenticates users depends on whether a RADIUS server is set up for that switch. For a switch with RADIUS support and configuration, authentication bypasses the local password database. For a switch without RADIUS support or configuration, authentication uses - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 138
configure on the proxy switch. Accounting Support The RADIUS service supports accounting request and response packets so that accounting records can be centralized on the RADIUS server. The login account name, assigned role, and password are stored on the RADIUS server for each user. Setting Up the - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 139
user guide 3. In the New RADIUS Client window: ■ In the Friendly name space, enter a name for the switch that allows you to identify it easily. ■ In the Client Address (IP or DNS) space, enter the IP address of the switch the policy name is listed (for example, HP User) and then click Next. 11. In - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 140
user guide Linux 14. In the Authentication tab: ■ Uncheck the following check boxes: - Microsoft® Encryption (MSCHAPv2) - Microsoft Encryption (MSCHAP) ■ Check the following check boxes: - Encrypted Authentication (CHAP) - Unencrypted Authentication (PAP, SPAP) 15. Select the Advanced tab. 16 HP - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 141
Local, User-Password == "johnPassword" HP-Auth-Role = "admin" 9. Save the user file. 10. Enter the following command to start the RADIUS server: /usr/local/sbin/radiusd 11. Log in to a client switch and issue the aaaconfig command to configure it as a client and enable RADIUS service, as described - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 142
user guide Setting Up the Switch The following procedures show how to use the aaaconfig command to set up a single switch for RADIUS service. You can also set up multiple switches simultaneously with the HP before the next server is contacted. The default is 3 seconds. Timeout values can range - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 143
Fabric OS procedures user guide To delete a RADIUS server from the configuration: 1. Issue the following the CHAP protocol for packets traveling between the switch and the server. To change the order in which RADIUS servers are contacted for service, issue the following command: aaaConfig "--move - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 144
with the legacy StorgeWorks SAN Switch Integrated/64 to provide detailed group information for a particular trap. For information on the specific commands used in these procedures, refer to online help or to the HP StorageWorks Fabric OS 3.1.x/4.1.x Reference Guide. 144 Fabric OS 3.x Document - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 145
user guide Configuring for SNMPv1 Use the following procedures to configure the SNMPv1 agent and traps. To display SNMP agent configuration information: Issue the agtCfgShow command, as in the following example: switch Switch sysLocation = End User Premise sysContact = Field Support 192.168.64.0 (rw - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 146
user guide To modify the SNMP configuration values, issue the agtCfgSet command, as in the following example: switch [FC Switch] sysLocation: [End User Premise] sysContact: [Field Support.] authTrapsEnabled host subnet area in dot notation: [0.0.0.0] 192.168.64.0 Read/Write? (true, t, false, f): [ - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 147
list configuration: Entry 0: Access host subnet area 192.168.64.0 (rw)] Entry 1: No access host configured yet reset to factory default Current SNMP Agent Configuration Customizable MIB-II system variables: sysDescr = Fibre Channel Switch sysLocation = End User Premise sysContact = Field Support - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 148
Fabric OS procedures user guide To modify the options for configuring SNMP MIB traps, issue the snmpmibcapset command, as in the following example: switch:admin> snmpmibcapset The SNMP Mib/Trap Capability has been set to support FE-MIB SW-MIB FA-MIB SW-TRAP FA-TRAP FA-MIB (yes, y, no, n): [yes] SW- - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 149
Fabric OS procedures user guide To view the SNMP MIB trap setup, issue the snmpmibcapshow command, as in the following example: switch:admin> snmpmibcapshow FE-MIB: YES SW-MIB: YES FA-MIB: YES SW-TRAP: YES swFCPortScn: NO swEventTrap: NO swFabricWatchTrap: NO swTrackChangesTrap: NO FA-TRAP: YES - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 150
Fabric OS procedures user guide 150 Fabric OS 3.x Document Addendum - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 151
modes. For information about these modes and Extended Fabrics in general, refer to the HP StorageWorks Extended Fabric Version 3.1.x/4.1.x User Guide. With this text: ISL Trunking is supported for normal E_Ports (referred to as L0 in the portcfglongdistance command) with LWL media - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 152
ISL trunking user guide Add the following section at the end of Chapter 1: Long-Distance Trunking This section provides information on long-distance trunking between Fabric OS v3.2 switches, including the SAN Switch 2/8 EL and SAN Switch 2/16. Long-distance ISL trunking is a new feature for Fabric - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 153
8 This chapter contains updates to the HP StorageWorks Fabric OS Version 3.1.x/4.1.x Reference Guide, part number AA-RS24C-TE. New and modified commands for Fabric OS v3.2.x: ■ aaaconfig (new for v3.2.x) ■ agtcfgshow ■ authutil ■ configdownload ■ configure ■ fabretryshow ■ fabricshow ■ fabstatsshow - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 154
Fabric OS reference guide ■ snmpmibcapshow ■ switchshow ■ switchstatusshow ■ tempshow ■ userconfig (new for v3.2.x) ■ zonecreate ■ zoneobjectcopy (new for v3.2.x) ■ zoneobjectexpunge (new for v3.2.x) ■ zoneobjectrename (new for v3.2.x) 154 Fabric OS 3.x Document Addendum - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 155
Fabric OS reference guide aaaconfig Syntax Availability required field is the IP address of the server. All other fields use defaults: port to 1812, timeout to 3 seconds, and protocol to CHAP. The and users are authenticated from the switch database. Fabric OS 3.x Document Addendum 155 - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 156
guide Example --switchdb [on | off] Enables or disables the switch users defined in the switch database from logging in to the switch. Service: RADIUS Secondary AAA Service: Switch database Auth-Protocol CHAP To add a RADIUS server with default values: switch:admin> aaaConfig "--add 10.64 - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 157
. sysLocation sysContact swEventTrapLevel The location of the system (switch) (in MIB-II definition). The default value is End User Premise. The contact information for this system (switch). The default value is Field Support. The event trap level with the event's severity level. When an event - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 158
:admin> agtcfgShow Current SNMP Agent Configuration Customizable MIB-II system variables: sysDescr = FC Switch sysLocation = End User Premise sysContact = Field Support. swEventTrapLevel = 3 authTrapsEnabled = true SNMPv1 community and trap recipient configuration: Community 1: Secret Code (rw) Trap - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 159
, dhchap is used. When no group is set, the default setting of *; for example, 0,1,2,3,4 is used. The new configuration is effective with the next authentication request. Use the --show option to display the current authentication configuration of the switch. Use the portshow command to display the - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 160
OS reference guide Operands only, and all to set FCAP and DH-CHAP (default). When authentication is set to all, implicit order is for instance, authentication negotiation FCAP is given priority over DH-CHAP on the local switch, but you can still select DH-CHAP. - -g value, which sets Diffie- - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 161
guide See Also To set all DH groups to be specified in authentication negotiate order of 0, 1, 2, 3, and 4: switch switch configuration from a host file. Syntax configdownload ["host", "user service 514). Both of these services together with instructions on how to that case the user is prompted for - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 162
Fabric OS reference guide The download can fail for any of the following reasons: ■ The switch has not been disabled. ■ The host name is not known to the switch. ■ The host IP address cannot be contacted. ■ The user does not have permission on the host. ■ The user runs a script that prints something - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 163
OS reference guide Note: Security parameters and the switch's identity cannot be changed by configdownload. Parameters such as the switch's name a forward slash ( / ). Relative path names search for the file in the user's home directory on UNIX hosts and in the directory where the FTP or RSHD server - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 164
Switch Fabric Settings" next ■ "Virtual Channel Settings" on page 167 ■ "Zoning Operation Parameter" on page 168 ■ "RSCN Transmission Mode" on page 169 ■ "Arbitrated Loop Settings" on page 169 ■ "System Services if appropriate), and a default value (shown in brackets). The default value is used with - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 165
Switch PID Format Per-Frame Route Priority Long-Distance Fabric Number Number Number Number Boolean Boolean Boolean Boolean Boolean Boolean Number Boolean Boolean Default 1 16 10000 2000 resolved before the timeout, the internal timeout clock resets and waits for the next error condition. E_D_TOV - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 166
reference guide WAN_TOV can be assigned to the other parameters. As a result, the user might not be able to set all the values within the range the switch's N_Port discovery process (PLOGI, PRLI, INQUIRY) causes some attached device to fail. Suppress Class F Traffic By default, the switch can send - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 167
2 Extended-edge PID format (16 based, 256 port format), used in mixed fabrics with legacy and new switches to avoid rebooting host systems when static PID binded is used If VC encoded address mode is not set, the default setting is 1. Note: The configdefault command does not change switch PID format - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 168
guide The default virtual channel settings have already been optimized for switch performance. Judiciously changing the default values might improve switch 6 VC Priority 7 Type Number Number Number Number Number Number Number Number Number Number Default 0 2 3 7 2 2 2 2 3 3 Range 0 to 1 2 to - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 169
mode values. Each field is described following the table. Table 16: RSCN Transmission Mode Field End-Device RSCN Transmission Mode Domain RSCN-to-End Device for Switch IP Address or Name Change Type Number Number Default 1 0 Range 0 to 2 0 to 1 End-Device RSCN Transmission Mode End-device - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 170
) 1 1 Open Deadlock Not fixed Not fixed Firmware fix Firmware fix Hardware fix Do Not Allow AL_PA 0x00? Some loop devices do not operate well with AL_PA 0 on the same loop. This option provides a workaround for such devices. By default, the switch can use a phantom AL_PA 0 for an embedded - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 171
Fabric OS reference guide Table 19: System Services Settings (Continued) Field rapid thad Disable RLS Probing Type Boolean Boolean Boolean Default 1 1 1 Range 0 or 1 0 or 1 0 or 1 rstatd Dynamically enables or disables a server that returns information through remote procedure calls (RPCs) - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 172
Fabric OS reference guide Operands Special Inputs Special inputs are: Carriage return Interrupt End-of-file When entered alone at a prompt without any preceding input, the command accepts the default value (if applicable) and moves to the next prompt. Aborts the command immediately and ignores - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 173
guide To configure: switch:admin> configure Configure... Fabric parameters (yes, y, no, n): [no] y Domain: (1..239) [1] BB credit: (1..27) [16] R_A_TOV: (4000..120000) [10000] E_D_TOV: (1000..5000) [2000 ?: (0..1) [0] Initialize All Looplets?: (0..1) [0] System services (yes, y, no, n): [no] y rstatd - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 174
Fabric OS reference guide See Also 174 Portlog events enable (yes, y, no, n): [no] y start(a switch start or re-start event ) disable(a port is disabled ) enable(a port is enabled ) ioctl(a port I/O control is executed) ) Tx(a frame is transmitted) ) Tx1(a frame is - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 175
Fabric OS reference guide switchenable uptime fabretryshow Syntax Availability Description Displays the retry count of the fabric commands. fabretryshow All users Use this command to display the retry count of various fabric commands. The first line of output displays SW_ISL, the ISL ports. - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 176
Fabric OS reference guide Example See Also To display the retry count of the fabric commands: switch:user> fabretryshow SW_ILS E_Ports 0 1 2 3 4 5 6 7 ELP 0 0 0 0 0 0 0 0 EMT 0 0 0 0 0 0 0 0 ETP 0 0 0 0 0 0 0 0 EFP 0 0 0 0 0 0 0 0 DIA 0 0 0 0 0 - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 177
.65.60 "sw60" 3: fffc43 10:00:00:60:69:10:60:1f 192.168.64.187 0.0.0.0 "sw187" 4: fffc40 10:00:00:60:69:00:06:56 192.168.64.59 192.168.65.59 "sw5" The Fabric has 4 switches Group ID Token 0: fffb01 40:05:00:00:10:00:00:60:69:00 - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 178
Fabric OS reference guide fabstatsshow Displays the fabric statistics information. Syntax fabstatsshow Availability All users Description Use this command to display the statistics information for the fabric. The following information is displayed: ■ Number of times a switch domain ID was - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 179
Example See Also Fabric OS reference guide To display the fabric statistics: switch:user> fabstatsshow Description Count Port Time Domain ID forcibly changed: . fwportdetailshow ["--p", "portNumber"] | ["--s", "portState"] All users Use this command to display the overall status of the - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 180
OS reference guide Operands Example all ports are displayed. The following operands are supported: --p portNumber Yields a port detail report information for specified ports: vxTarget:admin> fwportDetailShow Port Detail Report Switch Name: vxTarget IP address: 192.168.204.82 Port Exception - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 181
reference guide Sets parameters controlled by Fabric Watch. fwset ["--message", "mlevel"] | ["--port", "--persistence", "seconds"] All users Use before being actually recognized as such. To turn off console logging: switch:admin> fwSet "--message", "-1" Fabric OS 3.x Document Addendum 181 - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 182
OS reference guide To set the port persistence time to 18 seconds: switch:admin> fwSet "--port", "--persistence", "18" fwshow Syntax Availability Description Operands Examples 182 Displays the thresholds monitored by Fabric Watch. fwshow ["--message"] | ["--port", "--persistence"] All users If no - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 183
See Also Fabric OS reference guide To display valid thresholds named envTemp001: switch:admin> fwShow "envTemp001" Env Temperature 1: Monitored for: 1283 (21 mins) Last checked: 10:50:21 on 02/01/2000 Lower bound: Upper bound: Buffer Size: 0 C 75 C 10 Value history: 33 C Disabled? No - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 184
Admin Use this command to display detailed routing information from a source port (or area) on the local switch to a destination port (or area) on another switch. This routing information describes the exact path that a user data stream takes to go from the source to the destination. If the - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 185
guide over both a 1-second period and over a 64-second period. This gives an idea of both tracing of the reverse path is requested. The default value for the maximum hop count is 25. switches, or the reverse path might even involve different switches. The trace reverse path option allows the user - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 186
OS reference guide Operands Source route The source route option allows the user to specify a sequence of switches or ports area). The embedded port (-1) is used by default, or if the user specifies a destination port that is not active. For a switch with blades, the destination is specified as - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 187
hop. Note that if an output port (or area) to the next hop is specified, the user is not prompted for the domain of the next switch that is determined by the port (or area) specified. Default: no. Specifies that the source route must be followed strictly as indicated, skipping possible intermediate - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 188
Fabric OS reference guide To invoke pathinfo through the menu, including basic and extended statistics: switch:admin> pathInfo Max hops: (1..127) 0 E 9 (web226) 2 1G 1000 Port B/s (1s) B/s (64s) Txcrdz (1s) Txcrdz (64s) F/s (1s) F/s (64s) Words Frames Errors E 2 Tx Rx Tx Rx - - 0 - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 189
(64s) F/s (1s) F/s (64s) Words Frames Errors 14 E Tx Rx Tx Rx 0 0 - - 5 5 - - 0 - - - 0 - - - 0 0 - - 0 0 - - 20158695 1021842 - - 1665662 56849 - - - 4 - - portstatsshow switchshow Changes system passwords. passwd [ "login_name" ] All users Fabric - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 190
on the primary switch. The changed password database is distributed to all FCS switches. Non-FCS switches are updated if the password of the user account is changed. ■ The command is disabled until the user has changed all login passwords from the manufacturer's defaults or the switch was in secure - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 191
Also Fabric OS reference guide To change the admin password: switch:admin> passwd "admin" Old password: New password: Re-enter new password: Committing configuration...done. All error messages are preceded by the command name and followed by one of the following messages: "user" is not a valid - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 192
Fabric OS reference guide perfmonitorclear Syntax Description Operands Clears statistics counters of end-to-end, apply to ISL monitors. Examples To clear statistics counters for an end-to-end monitor: switch:admin> perfMonitorClear "EE", 2, 5 End-to-End monitor number 5 counters are cleared To - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 193
OS reference guide To clear statistics counters for an ISL monitor: switch:admin> perfMonitorClear port [, interval] Availability All users Description Use this command to display specified or 0 is specified, the command displays only the 64-bit frame in hexadecimal. When a nonzero interval is - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 194
Fabric OS reference guide Examples To display end-to-end monitors on port 3: switch:admin> perfMonitorShow "EE", 3 There are 2 end-to-end monitor(s) defined on port 3. KEY SID DID OWNER_APP OWNER_IP_ADDR TX_COUNT RX_COUNT CRC_COUNT 0 0xb1300 0xb23ef TELNET N/A 0x0000000000000000 - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 195
OS reference guide To display filter-based monitors on port 4 for every second (in this example, there are two monitors on port 4, 0 and 1): switch:admin> in this ISL; 16 domains are monitored because there are routes going to these domains by way of this ISL): switch:admin> perfmonitorshow "ISL - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 196
users Use this command to display previously defined end-to-end monitors on a port. When an interval is not specified or 0 is specified, the command displays the 64 operand is optional. Examples To display EE monitors on port 3: switch:admin> perfShowEEMonitor 3 There are 2 end-to-end monitor(s) - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 197
See Also Fabric OS reference guide To display all EE monitors on port 3 for every second (in this example, there are two monitors on port 3: 0, 1): switch:admin> perfShowEEMonitor 3, 1 Showing EE Monitors 3, 1: Tx/Rx are # of bytes and crc is # of crc errors 0 crc Tx Rx 0 0 1.2k 0 0 272 0 0 - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 198
Fabric OS reference guide Operands Example See Also The following operands are required: port_number The . When enabling ISL R_RDY mode and when the neighboring switch is of the same brand, the PID format between the switches must be the same. Note: The portcfgislmode and portcfglongdistance - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 199
command to allocate enough full-size frame buffers on a particular port to support a long-distance link up to 100 km. The port can be used persistent across switch reboots or power cycles. When this command is invoked without user-supplied operands, the operands are assigned default values. Fabric - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 200
guide The long-distance level string must be one of the following: L0 Reconfigure the port to be a regular switch port. The number of buffers reserved for the port supports reset protocol is used for long-distance links. When this parameter is not specified by the user, it is set to 1 by default. - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 201
to fabrics with long-distance links between StorageWorks 2 GB switches. Configurations with long-distance links between 2000- and 3000-series switches are not supported. To configure switch port 3 to support a 100 km link: switch:admin> portCfgLongDistance 3, "L2" Committing configuration...done - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 202
-duplex mode. portcfglport port_number, mode [,mode1] [,mode2] Admin Use this command to designate a port as an L_Port. The switch then attempts to initialize only that port as an FL_Port. By default, the L_Port is a public L_Port. It can be set as a private L_Port and the FLOGI is rejected. The - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 203
HD - - - YES - - - - Fairness To configure switch port 5: sw5:admin> portCfgLport 5, 0, 0, 2 Committing configuration...done portshow switchshow portshow Syntax Availability Displays port status. portshow port_number All users Fabric OS reference guide Fabric OS 3.x Document Addendum 203 - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 204
Fabric OS reference guide Description Use this command to display port status information. Some information varies with the switch model and port type. The output displays the following: portName A user-assigned name for the port. portHealth Authentication portFlags The current health of the - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 205
Fabric OS reference guide portData portId portWwn portWwn of devices connected Distance Address of the port's driver private data. The port's 24-bit D_ID. The port's World Wide Name. - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 206
Fabric OS reference guide The second column displays Link Error Status Block counters: Number of IUs with a nonzero status received. Lr_in Number of link reset requests received. Lr_out Number of link reset requests sent out. Ols_in Number of OLS Primitives received. Ols_out Number - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 207
Example See Also Fabric OS reference guide To display an E_Port: sw5:admin> portShow 3 portName: portHealth: HEALTHY Authentication: type DHCHAP, hash SHA1, group 0 portFlags: 0x28057 PRESENT ACTIVE E_PORT G_PORT U_PORT LOGIN LED - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 208
guide quietmode Sets or clears shell quiet mode. Syntax quietmode [newMode] Availability All users (display) Admin (set/clear) Description Use this command to affect the output displayed on the switch error log settings. By default, quiet mode is off and all switch tasks send output to the - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 209
Fabric OS reference guide secauthsecret Syntax Availability Description Operands Displays, sets, or . New data is effective with the next authentication request. The configuration applies to a switch instance only. Without any specified action, the command displays the usage. Specify action as - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 210
Fabric OS reference guide To set the shared secrets with a WWN, interactively: switch:admin> secAuthSecret "--set" This command authenticates peer. Press Enter to start setting up shared secrets > Enter WWN, Domain, or switch name (Leave blank when done): 10:00:00:60:69:80:05:14 Enter peer secret - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 211
switches in the fabric. ■ Resetting the root, factory, admin, and user account passwords on all FCS switches in the fabric. ■ Resetting the admin account password on all non-FCS switches issued, switches in the fabric with versions earlier than v4.4 and earlier than v3.2 firmware, reboots - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 212
using domain, WWN, or switch name. Specifying * defaults to all the switches currently in the fabric. --currentpwd Use the current passwords of the switch the command is run on (the primary FCS switch) for root, factory, admin, and user accounts. A non-FCS admin account password is set the same as - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 213
. If the FCS list of switches is not specified, the session becomes interactive and the user is prompted to enter FCS members. If the --currentpwd option is not used, the session becomes interactive and the user is prompted to enter new passwords for root, factory, admin, user, and non-FCS admin - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 214
: Warning: Access to the Root and Factory accounts may be required for proper support of the switch. Please ensure the Root and Factory passwords are documented in a secure location. Recovery of a lost Root or Factory password will result in fabric downtime. (continued on next page) 214 Fabric OS - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 215
guide Changing password for root New FCS switch root password: Re-type new password: Changing password for factory New FCS switch factory password: Re-type new password: Changing password for admin New FCS switch admin password: Re-type new password: Changing password for user New fabric wide user - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 216
Fabric OS reference guide See Also To use the current passwords option: fcsprimary:admin> secModeEnable "--currentpwd --fcs *" Your use of the certificate-based security features of the software installed on this equipment is subject to the End User License Agreement provided with the equipment - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 217
application can receive FA-TRAPS from the switch. The default value is yes. Users can also turn on or off default value is no. Note: The agtcfgdefault command also resets the SNMP MIB and trap capability to default along with other SNMP agent configuration. The values can be changed, if a user - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 218
Fabric OS reference guide Operands Example See Also None To set the SNMP MIB and trap capabilities of a switch: Cylon51:admin> snmpmibcapset The SNMP Mib/Trap Capability has been set to support FE-MIB SW-MIB FA-MIB SW-TRAP swFCPortScn swEventTrap swFabricWatchTrap swTrackChangesTrap FA-TRAP - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 219
application can receive FA-TRAPS from the switch. The default value is yes. Users can also turn on or off default value is no. Note: The agtcfgdefault command also resets the SNMP MIB and trap capability to default along with other SNMP agent configuration. The values can be changed, if a user - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 220
Fabric OS reference guide Operands Example See Also None To display the MIB and trap capabilities of a switch: Cylon51:admin> switch and port status. switchshow ["--option"] All users Use this command to display switch and port status information. Some information varies with the switch - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 221
Fabric OS reference guide switchState The switch's state: Online, Offline, Testing, or Faulty. switchMode The switch's mode: Interop or Native. switchRole The switch's role: Principal, Subordinate, or Disabled. switchDomain The switch's Domain ID: 0 through 31 or 1 through 239. switchId The - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 222
Fabric OS reference guide port state port distance comment more comments Disabled L_Port The port's only). - Loopback: The port is in loopback mode. - E_Port: Fabric port; displays WWN of attached switch. - F_Port: Point-to-point port; displays WWN of attached N_Port. - G_Port: Point-to-point but - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 223
Operand E_Port F_Port Fabric OS reference guide An E_Port displays one or more of the following: - WWN of the switch connected - Switch name of the switch connected - One or more interswitch link attributes - Trunk master: - The port is the master port in a group of trunking ports. - Trunk port, - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 224
Fabric OS reference guide Examples The following example displays a 16-port switch. Two ports are F_Ports (point-to-point connections to N_Ports), two ports are loop ports (one of which has eight private loop devices), and two ports are connected to another switch, sw6. If the optional -portcount - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 225
guide portcfgspeed portcfgtrunkport portdisable portenable switchdisable switchenable switchname switchstatusshow Syntax Availability Description Displays the overall status of the switch. switchstatusshow All users Use this command to display the overall status of the switch (enclosure - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 226
Report time: 07/22/2003 09:12:39 AM tempshow Syntax Availability Description Operands Displays temperature readings. tempshow All users Use this command to display the current temperature readings from each temperature sensor located on the switch's main printed circuit board (PCB - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 227
take on the permission or role of the default admin or user account. When the command completes, the account name and other attributes are saved persistently. On a platform supporting multiple domains, the affected accounts apply only to the switch domain from which the command was executed. In - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 228
Fabric OS reference guide --change username [options] --recover [options] Changes attributes for the account username. Recovers one or more accounts from backup; created by Secure Fabric OS operations. Note: The --show action is the only one available to accounts with user-level permission. All - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 229
guide Adds a new account named username to the switch, with the given authorization of rolename. The -d option gives a text description for the new account. This command also prompts for an initial password ASCII characters. - rolename must be either user, admin, or nonfcsadmin. The nonfcsadmin role - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 230
guide Examples --change username [-r rolename] [-d description] [-e yes | no] --recover Changes attributes for an existing account, named username, in the switch . Except the default root account, switch:admin> userConfig "--add joe -r admin -d Joe Smith" Enter new password: Re-type new password - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 231
Fabric OS reference guide To change account attributes: switch:admin> userConfig "--change joe -e no" beginning with a letter and followed by letters, numerals, and underscore characters) up to 64 characters. Names are case sensitive; for example, Zone_1 and zone_1 are different zones. Spaces - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 232
Fabric OS reference guide Zone alias names have the same format as zone names and are created with example, a zone defined with the members 2,12; 2,14; 10:00:00:60:69:00:00:8a contains devices connected to switch 2, ports 12 and 14, and the device with a World Wide Name of 10:00:00:60:69:00:00:8a - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 233
Fabric OS reference guide zoneobjectcopy Copies a zone object. Syntax zoneobjectcopy "objectName", "newName" . When security is enabled, this command can be issued only from the primary FCS switch. Operands Example This command has the following required operands: objectName The name of the - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 234
Fabric OS reference guide See Also cfgadd cfgclear cfgdelete cfgdisable cfgenable cfgremove cfgsave cfgshow and alias. This command changes the defined configuration. For the change to be preserved across switch reboots, it must be saved to nonvolatile memory, using the cfgsave command. For the - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 235
Example See Also Fabric OS reference guide To create a configuration containing three zones: switch:admin> cfgShow Defined configuration: cfg: USA_cfg Red_zone; White_zone; Blue_zone zone: Blue_zone 1,1; array1; 1,2; array2 zone: Red_zone 1,0; loop1 zone: White_zone 1,3; 1,4 alias: array1 21:00:00: - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 236
Fabric OS reference guide zoneobjectrename Renames a zone object. Syntax zoneobjectrename "objectName", "newName" When security is enabled, this command can be issued only from the primary FCS switch. Operands Example This command has the following required operands: objectName The name of the - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 237
See Also cfgadd cfgclear cfgdelete cfgdisable cfgenable cfgremove cfgsave cfgshow zoneobjectcopy Fabric OS reference guide Fabric OS 3.x Document Addendum 237 - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 238
Fabric OS reference guide 238 Fabric OS 3.x Document Addendum - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 239
to the HP StorageWorks Fabric Watch Version 3.1.x/4.1.x User Guide, part number AA-RTSGC-AA. On page 26, following the section "Activating with Web Tools," add the following: Fabric Watch Reports You can run reporting commands in Fabric Watch to get instant access to switch information. Although - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 240
Fabric Watch User Guide Fabric Watch threshold messages contain the following standard elements: severity, severity number, timestamp, message number, sequence number, severity, customer-assigned switch name, component name, message text, component state The following is a Fabric Watch threshold - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 241
Fabric Watch User Guide Table 21: Fabric Watch Message Elements (Continued) Format Element Description Component The element relevant to the message. Message Text Textual message containing up to eight - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 242
Fabric Watch User Guide Switch1_216:root> switchstatusshow Switch Health Report Switch Name: Switch1_216 IP address: 10.32.170.61 HEALTHY HEALTHY HEALTHY Report time: 09/17/2004 9:03:01 PM All ports are healthy value=0 Switch1_216:root> Figure 33: Switch Health Report The final portion - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 243
Fabric Watch User Guide >fwportdetailshow Port Detail Report Switch Name: swd21 IP address: 10.32.243.21 Port Exception report [by All] Report time: 01/16/2004 11:12:28 AM --------Port-Errors SFP-Errors---Port# Type State Dur(H:M) LFA LSY LSI PER INW CRC PSC STM SRX STX SCU SV0 - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 244
to an abnormal state. A port must remain in the abnormal state for a user-defined period of time before the port state affects the overall switch state. The monitor returns to a normal state when a problem is temporary. However, if the problem persists for 18 seconds or more, the state of the port - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 245
77 authorized reseller, HP 12 authutil command 159 B backing up config file 43 BB credit field 165 browsers supported by web tools 18 C camtest command 82 centralmemorytest command 84, 89 cfgenable command 232 cfgsave command 232 cfgshow command 232 changing account password - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 246
Index portcfgislmode 198 portcfglongdistance 151, 199 portcfglport 202 portcfgshow 200 portdisable 77 portenable 77 portloopbacktest 89, 104 portshow 113, 159 portstatsclear 192 qloopcreate 231 quietmode 208 ramtest 99 rsysinfo 171 rup 171 rusers 171 savecore 132 scsi inquiry 62 secauthsecret 78, 79 - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 247
81 firmware tab 28, 29 firmwaredownload command 132 fwportdetailshow command 179 fwset command 181 fwshow command 182 G gbicshow command 221 Fabric OS 3.x Document Addendum Index general tab 19 getting help 12 H help, obtaining 12 HP authorized reseller 12 storage web site 12 technical support 12 - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 248
127 SEC-SECVIOL_SERIAL 127 SEC-SECVIOL_TELNET 123 SEC-SECVIOL_WSNMP 128 modifying RADIUS server 51 modifying RADIUS server order 51 MS 167 perfshoweemonitor command 196 pkicert command 79 pkishow command 79 platforms supported by web tools 18 port detail report 242 port error persistence - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 249
139 RADIUS service, accounting support 139 RADIUS, use of 138 RAM requirements 18 ramtest command 99 rapid parameter 171 rebooting a switch 30 related 123 SEC-SECVIOL_WSNMP message 128 secure shell (SSH) 132 security features, configuring 131 sequence level switching field 166 severity level - HP StorageWorks MSA 2/8 | HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 250
69 firmware 28, 29 general 19 license admin 33 network configuration 27 port setting 35 routing (FSPF route) 44 routing (link cost) 46 routing (static route) 45 SNMP 31 switch information 26, 43 threshold configuration 54 trunk information 52 upload/download 29 zone 68 technical support, HP 12
document addendum
HP StorageWorks
Fabric OS 3.x
First Edition (January 2005)
Part Number:
AA–RW24A–TE
This document is an addendum for Fabric OS users to supplement the Fabric OS version 3.x documentation
set. This document is specific to Fabric OS version 3.x and all switches running Fabric OS version 3.x,
including the HP StorageWorks SAN Switch 2/8 EL, SAN Switch 2/16, and MSA SAN Switch 2/8.