HP StorageWorks MSA 2/8 HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 91
Diag-errstat Badeof, Diag-errstat Badord
View all HP StorageWorks MSA 2/8 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 91 highlights
Diagnostic and system error messages reference guide DIAG-ERRSTAT (BADEOF) Message CRITICAL DIAG-ERRSTAT (BADEOF), 1, , pass , Pt BadEOF Error Counter is sb 0, Err# Probable Cause The Port Error Statistics counter is nonzero, which means that a Bad end of file error was detected when receiving frames. This can be caused by a faulty cable or deteriorated SFP. It can also indicate more serious problems in the motherboard or ASIC. This message is generated by the portloopbacktest or spinsilk command. The error code value is for internal use only. Recommended Action Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if necessary. If the problem persists: ■ For the SAN Switch 2/16, replace the motherboard FRU. ■ For the SAN Switch 2/8 EL, replace the entire switch. Severity CRITICAL DIAG-ERRSTAT (BADORD) Message CRITICAL DIAG-ERRSTAT (BADORD), 1, , pass , Pt BadOrdSet Error Counter is sb 0, Err# Probable Cause The Port Error Statistics counter is nonzero, which means that a Bad symbol on fiber-optic cable error was detected when receiving frames. This can be caused by a faulty cable or deteriorated SFP. It can also indicate more serious problems in the motherboard or ASIC. This message is generated by the portloopbacktest or spinsilk command. The error code value is for internal use only. Fabric OS 3.x Document Addendum 91