HP StorageWorks MSA 2/8 HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 206
Operand, Number of OLS Primitives received.
View all HP StorageWorks MSA 2/8 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 206 highlights
Fabric OS reference guide The second column displays Link Error Status Block counters: Link_failure Number of times the port enters LF1 or LF2 state. Loss_of_sync Number of times the port enters a loss of sync state. Loss_of_sig Number of times the port enters a loss of signal state. Protocol_err Invalid_word Number of occurrences of the link failure condition in which either an LR or LRR primitive sequence was received while in OL3 (wait for OLS) state. Number of encoding/disparity errors inside of frames. Invalid_crc Number of CRC errors. Delim_err Number of SOF or EOF errors. Address_err Number of IUs with a nonzero status received. Lr_in Number of link reset requests received. Lr_out Number of link reset requests sent out. Ols_in Number of OLS Primitives received. Ols_out Number of OLS Primitives sent out. Operand The third column displays the number of F_RJTs and F_BSYs generated. For L_Ports, the third column also displays the number of LIPs received, the number of LIPs transmitted, and the last LIP received. Frjt Number of fabric reject messages sent out. Fbsy Number of fabric busy messages sent out. The following operand is required: port_number The port number to be displayed: 0 through 7 or 0 through 15. 206 Fabric OS 3.x Document Addendum