HP StorageWorks MSA 2/8 HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 102
Diag-portabsent, Diag-portdied
View all HP StorageWorks MSA 2/8 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 102 highlights
Diagnostic and system error messages reference guide Severity CRITICAL DIAG-PORTABSENT Message CRITICAL DIAG-PORTABSENT, 1, , pass , Pt is not present, cannot run test, Err# Probable Cause The port is not present. This can be caused by a faulty cable or deteriorated SFP. It can also indicate more serious problems in the motherboard or ASIC. This message is generated by the portloopbacktest or spinsilk command. The error code value is for internal use only. Recommended Action Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if necessary. If the problem persists: ■ For the SAN Switch 2/16, replace the motherboard FRU. ■ For the SAN Switch 2/8 EL, replace the entire switch. Severity CRITICAL DIAG-PORTDIED Message CRITICAL DIAG-PORTDIED, 1, DIAG-PORTDIED , pass , Pt Was Active but Went Inactive (Offline), Err# Probable Cause The port was in loopback mode and then went inactive. This can be caused by a faulty cable or deteriorated SFP. It can also indicate more serious problems in the motherboard or ASIC. This message is generated by the crossporttest, portloopbacktest, or spinsilk command. The error code value is for internal use only. 102 Fabric OS 3.x Document Addendum