HP StorageWorks MSA 2/8 HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 118
Sec-pidchginfo, Sec-rsendfail
View all HP StorageWorks MSA 2/8 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 118 highlights
Diagnostic and system error messages reference guide SEC-PIDCHGINFO Message INFO SEC-PIDCHGINFO, 4, PID Change: Success Probable Cause The PID format of the switch was changed either to extended-edge PID or from extended-edge PID. If DCC policies existed, all area ID values either increased or decreased by 16. The values wrap around after a port value of 128. If a DCC policy contains an area of 127 before changing to extended edge PID, the new area is 15 because of the wraparound. Recommended Action No action is required. Severity INFO SEC-RSENDFAIL Message ERROR SEC-RSENDFAIL, 2, RCS process fails: %s Probable Cause The Reliable Commit Service (RCS) process failed to complete. RCS is a reliable mechanism to transfer data from one switch to the other switches within the fabric. This mechanism guarantees that either all switches commit to the new database or none of them update to the new database. This process can fail if one switch in the fabric is busy or in an error state that can not accept the database. Recommended Action RCS is used when the security database is changed by a command issued by security (for example, secpolicysave, secpolicyactivate, and secversionreset). If the switch is busy, the command might fail the first time; retry the command. If the command fails consistently, copy the message, collect switch information using the supportshow command, and contact your switch service provider. Severity ERROR 118 Fabric OS 3.x Document Addendum