HP StorageWorks MSA 2/8 HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 89
Diag-cmnobuf, Diag-data
View all HP StorageWorks MSA 2/8 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 89 highlights
Diagnostic and system error messages reference guide DIAG-CMNOBUF Message CRITICAL DIAG-CMNOBUF, 1, , pass , Pt No More Buffers, Err# Probable Cause The port could not get any buffers. This usually indicates an ASIC failure. This message is generated by the centralmemorytest command. The error code value is for internal use only. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL, replace the entire switch. Severity CRITICAL DIAG-DATA Message CRITICAL DIAG-DATA, 1, , pass , Pt-Pt: RX Data is 0x sb 0x er 0x%, Err# Probable Cause The payload received by a port did not match the payload transmitted. This can be caused by a faulty cable or deteriorated SFP. It can also indicate more serious problems in the motherboard or ASIC. This message is generated by the crossporttest or portloopbacktest command. The error code value is for internal use only. Recommended Action Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if necessary. If the problem persists: ■ For the SAN Switch 2/16, replace the motherboard FRU. ■ For the SAN Switch 2/8 EL, replace the entire switch. Fabric OS 3.x Document Addendum 89