HP StorageWorks MSA 2/8 HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 106
Diag-regerr_unrst, Diag-stats C3frx - how to reset san switch
View all HP StorageWorks MSA 2/8 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 106 highlights
Diagnostic and system error messages reference guide DIAG-REGERR_UNRST Message CRITICAL DIAG-REGERR_UNRST, 1, , Pt failed to unreset despite retries, lli_ctl is sb 90000, port_config is sb 0, Err# Probable Cause The port failed to un-reset. This usually indicates an ASIC failure. This message is generated by the portregtest or the sramretentiontest command. The error code value is for internal use only. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL, replace the entire switch. Severity CRITICAL DIAG-STATS (C3FRX) Message CRITICAL DIAG-STATS (C3FRX), 1, , pass , Pt Cl3FrmRx Counter Wrong, is sb , Err# Probable Cause The port counter value did not match the number of frames actually transmitted. In this case, Cl3FrmRx equals the number of Class 3 frames received. This can be caused by a faulty cable or deteriorated SFP. It can also indicate more serious problems in the motherboard or ASIC. This message is generated by the portloopbacktest command. The error code value is for internal use only. Recommended Action Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if necessary. If the problem persists: ■ For the SAN Switch 2/16, replace the motherboard FRU. ■ For the SAN Switch 2/8 EL, replace the entire switch. 106 Fabric OS 3.x Document Addendum