HP StorageWorks MSA 2/8 HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 126
Sec-secviol_msop, Sec-secviol_rsnmp
View all HP StorageWorks MSA 2/8 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 126 highlights
Diagnostic and system error messages reference guide SEC-SECVIOL_MSop Message INFO SEC-SECVIOL_MSop, 4, Security violation: MS device operates on non primary FCS switch. Probable Cause An MS operation security violation was reported. A management server device is operating on a nonprimary FCS switch. Recommended Action Check the management server policy and verify that the connection is allowed. If the connection is allowed but not specified, enable the connection in the MS policy. If the MS policy does not allow the connection, this is a valid violation message and an unauthorized entity is trying to access your fabric. Take appropriate action as defined by your enterprise security policy. Severity INFO SEC-SECVIOL_RSNMP Message INFO SEC-SECVIOL_RSNMP, 4, Security violation: Unauthorized host with IP address tries to do SNMP read operation. Probable Cause An SNMP security violation was reported. The specified unauthorized host attempted to perform a read SNMP operation (RSNMP). Recommended Action Check RSNMP policy to verify that hosts allowed access to the fabric through SNMP read operations are included in the RSNMP policy. If the host is allowed access to the fabric but is not included in the RSNMP policy, add the host to the policy. If the host is not allowed access to the fabric, this is a valid violation message and an unauthorized entity is trying to access your fabric. Take appropriate action as defined by your enterprise security policy. Severity INFO 126 Fabric OS 3.x Document Addendum