HP StorageWorks MSA 2/8 HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 81

Diag-camfltr, Diag-caminit

Page 81 highlights

Diagnostic and system error messages reference guide DIAG-CAMFLTR Message CRITICAL DIAG-CAMFLTR, 1, , pass , Pt Failed Filter Test (test=, match:), filter on (sb:) action type: (sb:) Err# Probable Cause The ASIC internal logic failed. This usually indicates an ASIC failure. This message is generated by the filtertest command. The error code value is for internal use only. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8 EL, replace the entire switch. Severity CRITICAL DIAG-CAMINIT Message CRITICAL DIAG-CAMINIT, 1, , pass , Pt Failed to Init: , Err# Probable Cause A port failed to initialize due to one of the following reasons: ■ Switch is not disabled. ■ Diagnostic queue is absent. ■ Malloc failed. ■ Chip is not present. ■ Port is not in loopback mode. ■ Port is not active. ■ There was a software operational setup error or motherboard failure. ■ There occurred a retry, reboot, or replacement of motherboard assembly. Fabric OS 3.x Document Addendum 81

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250

Diagnostic and system error messages reference guide
81
Fabric OS 3.x Document Addendum
DIAG-CAMFLTR
Message
Probable Cause
The ASIC internal logic failed. This usually indicates an ASIC failure. This message is
generated by the
filtertest
command. The
error code
value is for internal use only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
DIAG-CAMINIT
Message
Probable Cause
A port failed to initialize due to one of the following reasons:
Switch is not disabled.
Diagnostic queue is absent.
Malloc failed.
Chip is not present.
Port is not in loopback mode.
Port is not active.
There was a software operational setup error or motherboard failure.
There occurred a retry, reboot, or replacement of motherboard assembly.
<timestamp>
CRITICAL DIAG-CAMFLTR, 1, <test name>, pass <number>,
Pt<port info> Failed Filter Test (test=<test number>, match:<cam type>),
filter <hit | nhit> on <actual filter number>(sb:<expected filter number>)
action type: <actual action>(sb:<expected action>)
Err# <error code>
<timestamp>
CRITICAL DIAG-CAMINIT, 1, <test name>, pass <number>,
Pt<port information> Failed to Init: <additional message>,
Err# <error code>