HP StorageWorks MSA 2/8 HP StorageWorks Fabric OS 3.X Document Addendum (AA-RW - Page 108
Diag-stats Ftx, Diag-tbram_dec_rwtest
View all HP StorageWorks MSA 2/8 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 108 highlights
Diagnostic and system error messages reference guide DIAG-STATS (FTX) Message CRITICAL DIAG-STATS (FTX), 1, , pass , Pt FramesTx Counter Wrong, is sb , Err# Probable Cause The port counter value did not match the number of frames actually transmitted. In this case, FramesTx equals the number of frames transmitted. This can be caused by a faulty cable or deteriorated SFP. It can also indicate more serious problems in the motherboard or ASIC. This message is generated by the portloopbacktest command. The error code value is for internal use only. Recommended Action Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if necessary. If the problem persists: ■ For the SAN Switch 2/16, replace the motherboard FRU. ■ For the SAN Switch 2/8 EL, replace the entire switch. Severity CRITICAL DIAG-TBRAM_DEC_RWTEST Message CRITICAL DIAG-TBRAM_DEC_RWTEST, 1, , pass , Pt Failed Turbo RAM dec r/w test: phy=0x wrd cnt= inc size= bytes rpt=0x wpt=0x msk=0x Err# Probable Cause The ASIC internal registers failed the read-modify-write operation. This usually indicates an ASIC failure. This message is generated by the turboramtest command. The error code value is for internal use only. 108 Fabric OS 3.x Document Addendum