HP StorageWorks MSA 2/8 HP StorageWorks Secure Fabric OS V1.0 User Guide (AA-R - Page 56

Failing over the Primary FCS Switch, In addition to failing over the Primary FCS role

Page 56 highlights

Creating Secure Fabric OS Policies Example, moving a Backup FCS switch from position 2 to position 3 in the FCS list using interactive mode: primaryfcs:admin> secpolicyfcsmove Pos Primary WWN DId swName. 1 Yes 10:00:00:60:69:10:02:18 1 switch5. 2 No 10:00:00:60:69:00:00:5a 2 switch60. 3 No 10:00:00:60:69:00:00:13 3 switch73. Please enter position you'd like to move from : (1..3) [1] 2 Please enter position you'd like to move to : (1..3) [1] 3 DEFINED POLICY SET FCS_POLICY Pos Primary WWN DId swName. 1 Yes 10:00:00:60:69:10:02:18 1 switch5. 2 No 10:00:00:60:69:00:00:13 3 switch73. 3 No 10:00:00:60:69:00:00:5a 2 switch60. primaryfcs:admin> 4. Enter the secpolicyactivate command. Failing over the Primary FCS Switch The secfcsfailover command is used to fail over the Primary FCS role to the Backup FCS switch from which you enter the command. This can be used to recover from events such as a lost Ethernet connection to the Primary FCS switch. In addition to failing over the Primary FCS role, this command moves the new Primary FCS switch to the top of the list in the FCS policy. Note: Disabling a switch or removing it from the fabric does not change the order of the FCS policy. During FCS failover, all transactions in process on the current Primary FCS are aborted. 56 Secure Fabric OS Version 1.0 User Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129

Creating Secure Fabric OS Policies
56
Secure Fabric OS Version 1.0 User Guide
Example, moving a Backup FCS switch from position 2 to position 3 in the
FCS list using interactive mode:
4.
Enter the
secpolicyactivate
command.
Failing over the Primary FCS Switch
The
secfcsfailover
command is used to fail over the Primary FCS role to
the Backup FCS switch from which you enter the command. This can be used to
recover from events such as a lost Ethernet connection to the Primary FCS switch.
In addition to failing over the Primary FCS role, this command moves the new
Primary FCS switch to the top of the list in the FCS policy.
Note:
Disabling a switch or removing it from the fabric does not change the order of
the FCS policy.
During FCS failover, all transactions in process on the current Primary FCS are
aborted.
primaryfcs:admin> secpolicyfcsmove
Pos Primary WWN
DId swName.
=================================================
1
Yes
10:00:00:60:69:10:02:18 1
switch5.
2
No
10:00:00:60:69:00:00:5a 2
switch60.
3
No
10:00:00:60:69:00:00:13 3
switch73.
Please enter position you’d like to move from : (1..3) [1] 2
Please enter position you’d like to move to : (1..3) [1] 3
____________________________________________________
DEFINED POLICY SET
FCS_POLICY
Pos Primary WWN
DId swName.
__________________________________________________
1
Yes
10:00:00:60:69:10:02:18 1
switch5.
2
No
10:00:00:60:69:00:00:13 3
switch73.
3
No
10:00:00:60:69:00:00:5a 2
switch60.
____________________________________________________
primaryfcs:admin>