Yamaha 2.0 Owner's Manual - Page 128

GrvCheck, single, Break TB, T=0 B=0

Page 128 highlights

Feature Reference - Utility Mode 37 GrvCheck (groove check) This sets the Groove Check mode from the following two types: Rotate the Data Scroll Wheel or use the +1/YES and -1/NO buttons to set the parameter. The following two types are available. single The DTX shows how loose the data received from a pad or drum is from the beat in clock units. This is convenient to check the timing of a snare or kick. The minimum unit value of the groove check function depends on the quantization setting of the click. average ......... The LCD diaplays the average percentage of the beat timing against the precise beat of the groove check. 100% stands for 1/ 16th note quantization. This enables you to check the groove of the entire drum set. GrvCheck = single MISC. CYMBAL SNARE KICK Settings: single, average ARefer to P.97 for further details on the groove check function. 124 38 Break TB (break top/bottom) This function enables you to insert a break into the rhythm in Pattern Play mode. (Only the rhythm of the specified measure(s) will be muted.) Set the length of the break by selecting the number of measures. ! First select the pattern in Pattern Play mode and enter this page. " Move the cursor to T (TOP) and B (BOTTOM) using the Q cursor buttons and set the number of the measure to break (mute) by rotating the Data Scroll Wheel or using the +1/YES and -1/NO buttons. T and B have the following functions: T (TOP Mutes the selected measures of the rhythm part from the beginning of the pattern. B (BOTTOM) ...... Mute the selected measures of the rhythm part from the end of the pattern. For example, if you want to mute the rhythm part of the 1st and 4th measures of a 4-measure pattern, set the number in the T and B focus areas to "1". 4-measure pattern 1 2 3 4 mute T=1 mute B=1 ASet the T and B focus areas to "0" if you are not muting any of the measures in this pattern. # Press the START/STOP button to exit this function and the mute settings will be effective on the currently selected pattern. A This function will affect all patterns, and therefore the result may not be what you intend if you apply the same setting to a pattern with a different number of measures. Break TB T (TOP) B (BOTTOM) T=0 B=0 MISC. CYMBAL SNARE KICK Settings: T (TOP): 0 to 8 B (BOTTOM): 0 to 8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174

124
Feature Reference
Utility Mode
37
GrvCheck (groove check)
This sets the Groove Check mode from the
following two types:
Rotate the Data Scroll Wheel or use the +1/YES
and -1/NO buttons to set the parameter.
The
following two types are available.
single
............
The DTX shows how loose the data
received from a pad or drum is from the
beat in clock units.
This is convenient to
check the timing of a snare or kick.
The
minimum unit value of the groove check
function depends on the quantization
setting of the click.
average
.........
The LCD diaplays the average percentage
of the beat timing against the precise beat
of the groove check.
100% stands for 1/
16th note quantization.
This enables you
to check the groove of the entire drum set.
MISC.
SNARE
KICK
CYMBAL
GrvCheck
= single
Settings:
single, average
A
Refer to
P.97 for further details on the groove check
function.
38
Break TB (break top/bottom)
This function enables you to insert a break into
the rhythm in Pattern Play mode.
(Only the
rhythm of the specified measure(s) will be
muted.)
Set the length of the break by selecting
the number of measures.
!
First select the pattern in Pattern Play mode
and enter this page.
"
Move the cursor to T (TOP) and B
(BOTTOM) using the
Q
cursor
buttons and set the number of the measure
to break (mute) by rotating the Data Scroll
Wheel or using the +1/YES and -1/NO
buttons.
T and B have the following
functions:
T (TOP)
..............
Mutes the selected measures of the
rhythm part from the beginning of the
pattern.
B (BOTTOM)
......
Mute the selected measures of the
rhythm part from the end of the
pattern.
For example, if you want to mute the rhythm
part of the 1st and 4th measures of a 4-measure
pattern, set the number in the T and B focus
areas to
1
.
4-measure pattern
mute
mute
T=1
B=1
1
2
3
4
A
Set the T and B focus areas to
0
if you are not muting
any of the measures in this pattern.
#
Press the START/STOP button to exit this
function and the mute settings will be
effective on the currently selected pattern.
A
This function will affect all patterns, and therefore the
result may not be what you intend if you apply the same setting
to a pattern with a different number of measures.
MISC.
SNARE
KICK
CYMBAL
Break TB
T=0 B=0
B (BOTTOM)
T (TOP)
Settings:
T (TOP):
0 to 8
B (BOTTOM)
: 0 to 8