Dell PowerConnect J-8216 Hardware Guide

Dell PowerConnect J-8216 Manual

Dell PowerConnect J-8216 manual content summary:

  • Dell PowerConnect J-8216 | Hardware Guide - Page 1
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Published: 2010-10-05
  • Dell PowerConnect J-8216 | Hardware Guide - Page 2
    routing protocol. Development of GateD has been supported in part by the National Science Foundation trademarks, service marks, registered trademarks, or registered service marks ,186, and 6,590,785. Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide © Copyright Dell, Inc. , 2010. All
  • Dell PowerConnect J-8216 | Hardware Guide - Page 3
    , please see the Juniper Networks Web site at www.juniper.net/techpubs. END USER LICENSE AGREEMENT READ THIS END USER LICENSE AGREEMENT Enterprise Edition of the Steel-Belted Radius software to support any commercial network access services. The foregoing license is not transferable or assignable by
  • Dell PowerConnect J-8216 | Hardware Guide - Page 4
    to support the Software. Support services may be purchased separately. Any such support shall be governed by a separate, written support services agreement. revoked or modified. All payments made by Customer shall be net of any applicable withholding tax. Customer will provide reasonable assistance
  • Dell PowerConnect J-8216 | Hardware Guide - Page 5
    . Any licensor of Juniper whose software is embedded in the Software and any supplier of Juniper whose products or technology are embedded in (or services are accessed by) the Software shall be a third party beneficiary with respect to this Agreement, and such licensor or vendor shall have the right
  • Dell PowerConnect J-8216 | Hardware Guide - Page 6
    vi
  • Dell PowerConnect J-8216 | Hardware Guide - Page 7
    Chapter 1 Chapter 2 About This Guide xiii How to Use This Guide xiii Downloading Software xiv Documentation Conventions xiv Repair and Warranty xv Requesting Technical Support xv Switch and Components Overview and Specifications Dell PowerConnect J-Series J-EX8216 Switch Overview 3 J-EX8216
  • Dell PowerConnect J-8216 | Hardware Guide - Page 8
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Chapter 3 Part 2 Chapter 4 Chapter 5 Chapter 6 Chapter 7 48-port RJ- Port Connector Pinout Information for a J-EX8200 Switch 50 Optical Interface Support in J-EX8200 Switches 51 Grounding Cable and Lug Specifications for J-EX8200
  • Dell PowerConnect J-8216 | Hardware Guide - Page 9
    Table of Contents Part 3 Chapter 8 Chapter 9 Chapter 10 Chapter 11 Part 4 Chapter 12 Calculating the Number of Power Supplies Required for Your J-EX8216 Switch Configuration 88 Calculating the J-EX8200 Switch Fiber-Optic Cable Power Budget 91 Calculating the J-EX8200 Switch Fiber-Optic Cable
  • Dell PowerConnect J-8216 | Hardware Guide - Page 10
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Chapter 13 Part 5 Chapter 14 Part 6 Chapter 15 Removing Switch Components 183 Online Services 184 Automated Order-Status Service 185 Support Service 185 Dell Enterprise Training and Certification 185 Problems With Your Order
  • Dell PowerConnect J-8216 | Hardware Guide - Page 11
    Warning 208 Radiation from Open Port Apertures Warning for J-EX Series Switches 210 Installation and Maintenance Safety Information 213 Installation Instructions Warning for J-EX Series Switches 213 Chassis Lifting Guidelines for J-EX8200 Switches 214 Ramp Warning for J-EX Series Switches 214
  • Dell PowerConnect J-8216 | Hardware Guide - Page 12
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Part 9 Non-Regulatory Environmental Standards 242 Compliance Statements for Acoustic Noise for J-EX Series Switches 242 Declarations of Conformity for J-EX8216 Switches 243 Index Index 247 xii
  • Dell PowerConnect J-8216 | Hardware Guide - Page 13
    following Dell support website: http://www.support.dell.com/manuals Table 1: List of J-EX Series Guides Title Description Dell PowerConnect EX Series and all other PowerConnect J-Series products, see the following Juniper Networks support website: http://www.juniper.net/techpubs/ . If the
  • Dell PowerConnect J-8216 | Hardware Guide - Page 14
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Downloading Software You can download Junos OS for J-EX Series switches from the Download Software area at http://www.support.dell.com/ . To download the software, you must have a Juniper Networks user account. For information
  • Dell PowerConnect J-8216 | Hardware Guide - Page 15
    About This Guide Table troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
  • Dell PowerConnect J-8216 | Hardware Guide - Page 16
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide xvi
  • Dell PowerConnect J-8216 | Hardware Guide - Page 17
    PART 1 Switch and Components Overview and Specifications • Dell PowerConnect J-Series J-EX8216 Switch Overview on page 3 • Component Descriptions on page 19 • Component Specifications on page 49 1
  • Dell PowerConnect J-8216 | Hardware Guide - Page 18
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide 2
  • Dell PowerConnect J-8216 | Hardware Guide - Page 19
    (SF) modules, fan trays (with redundant fans), and load-sharing 2000 W AC and 3000 W AC power supplies. Like other Dell PowerConnect J-EX8200 Series Ethernet Switches, J-EX8216 switches provide high performance, scalable connectivity, and carrier-class reliability. You can manage J-EX8216 switches
  • Dell PowerConnect J-8216 | Hardware Guide - Page 20
    J-Series J-EX8216 Ethernet Switch Hardware Guide OS, which provides Layer 2 and Layer 3 switching, routing, and security services. The same Junos OS code base that runs on J-EX Series switches also runs on Dell PowerConnect J-SRX Series Services Gateways. Chassis Physical Specifications, LCD
  • Dell PowerConnect J-8216 | Hardware Guide - Page 21
    Chapter 1: Dell PowerConnect J-Series J-EX8216 Switch Overview Figure 2: J-EX8216 Switch Rear The J-EX8216 switch has a chassis-level LCD panel that displays Routing Engine and switch fabric status as well as chassis components' alarm information for rapid problem identification. The LCD panel
  • Dell PowerConnect J-8216 | Hardware Guide - Page 22
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Line Cards Cooling System installed in the front Switch" on page 29. The J-EX8216 switch features 16 horizontal line card slots and supports wire-rate performance for all packet sizes for the installed line cards. The line cards
  • Dell PowerConnect J-8216 | Hardware Guide - Page 23
    Chapter 1: Dell PowerConnect J-Series J-EX8216 Switch Overview Power Supplies Power supplies for can hold up to six 2000 W AC or six 3000 W AC power supplies. The 2000 W AC power supplies support both low-line (100-120 VAC) and high-line (200-240 VAC) AC power configurations on a J-EX8216 switch
  • Dell PowerConnect J-8216 | Hardware Guide - Page 24
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Table 4: J-EX8216 Switch Hardware Configurations (continued) Switch Configuration Configuration Components Redundant configuration (AC with 3000 W AC power supplies) • Chassis with midplane • Two fan trays • Two
  • Dell PowerConnect J-8216 | Hardware Guide - Page 25
    Chapter 1: Dell PowerConnect J-Series J-EX8216 Switch Overview • 48-port RJ-45 Line Card in a J-EX8200 Switch on page 34 • Cooling System and Airflow in a J-EX8216 Switch on page
  • Dell PowerConnect J-8216 | Hardware Guide - Page 26
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Figure 3: J-EX8216 Switch Front Figure 4 on page 11 shows the rear of a J-EX8216 switch. 10
  • Dell PowerConnect J-8216 | Hardware Guide - Page 27
    Chapter 1: Dell PowerConnect J-Series J-EX8216 Switch Overview Figure 4: J-EX8216 Switch Rear You can handles to lift the chassis manually. Failure to heed this warning can result in injury. See "Mounting a J-EX8216 Switch on a Rack or Cabinet" on page 108 for instructions for lifting a chassis.
  • Dell PowerConnect J-8216 | Hardware Guide - Page 28
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide • Installing and Removing J-EX8216 Switch Hardware Components on page 113 Understanding J-EX8216 Switch Component and Functionality Redundancy The J-EX8216 Ethernet Switch is available as a fully
  • Dell PowerConnect J-8216 | Hardware Guide - Page 29
    Chapter 1: Dell PowerConnect J-Series J-EX8216 Switch Overview Each fan tray continues to SF) modules. We recommend that you install all eight SF modules in a J-EX8216 switch to support maximum midplane performance for the installed line cards. All SF modules are fully connected to all installed
  • Dell PowerConnect J-8216 | Hardware Guide - Page 30
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Slot Numbering for a J-EX8216 Switch A J-EX8216 chassis accepts 16 line cards, two Routing Engine (RE) modules, eight Switch Fabric (SF) modules, two fan trays, and
  • Dell PowerConnect J-8216 | Hardware Guide - Page 31
    Chapter 1: Dell PowerConnect J-Series J-EX8216 Switch Overview Figure 5: Slot Numbering on the Fan Trays on a J-EX8216 Switch Chassis Front Slots RE0 and RE1 accept only the RE modules.
  • Dell PowerConnect J-8216 | Hardware Guide - Page 32
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Slot Numbering for the Power Supply 39. CAUTION: Mixing different types of power supplies in the same chassis is not a supported configuration. Table 9: Slot Numbering for Power Supply Slots on a J-EX8216 Switch Chassis Front
  • Dell PowerConnect J-8216 | Hardware Guide - Page 33
    Chapter 1: Dell PowerConnect J-Series J-EX8216 Switch Overview Slot Numbering for the SF Module Slots Table 10 on page 17 lists the slot numbers on the J-EX8216 chassis rear
  • Dell PowerConnect J-8216 | Hardware Guide - Page 34
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Slots SF7 through SF0 (from left to right) accept SF modules. See "Switch Fabric (SF) Modules in a J-EX8216 Switch" on page 29. We recommend you
  • Dell PowerConnect J-8216 | Hardware Guide - Page 35
    CHAPTER 2 Component Descriptions • LCD Panel in a J-EX8200 Switch on page 19 • Chassis Status LEDs in a J-EX8200 Switch on page 24 • Field-Replaceable Units in a J-EX8216 Switch on page 25 • Routing Engine (RE) Module in a J-EX8216 Switch on page 26 • RE Module LEDs in a J-EX8216 Switch on page 27 •
  • Dell PowerConnect J-8216 | Hardware Guide - Page 36
    to display a custom message, the Menu button and the Enter button are disabled. For instructions, see the Dell PowerConnect J-Series Ethernet Switch Complete Software Guide for Junos OS at http://www.support.dell.com/manuals. The LCD panel has a backlight. If the LCD panel is idle for 60 seconds
  • Dell PowerConnect J-8216 | Hardware Guide - Page 37
    tray(s) and chassis temperature • Junos OS version installed The maintenance mode allows you to cycle through options for configuring and troubleshooting the switch: • System halt • Reboot system • Load rescue configuration • Revert to factory configuration • EZSetup LCD Panel Menus The LCD has
  • Dell PowerConnect J-8216 | Hardware Guide - Page 38
    the Switch fabric status option. If you do not want users to use Status menu options, disable the entire menu or individual menu options. For instructions, see the Dell PowerConnect J-Series Ethernet Switch Complete Software Guide for Junos OS at http://www.support.dell.com/manuals. 22
  • Dell PowerConnect J-8216 | Hardware Guide - Page 39
    use Maintenance menu options, disable the entire menu or individual menu options. For instructions, see the Dell PowerConnect J-Series Ethernet Switch Complete Software Guide for Junos OS at http://www.support.dell.com/manuals. You can view the information about the LCD panel in J-EX8200 switches
  • Dell PowerConnect J-8216 | Hardware Guide - Page 40
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Chassis Status LEDs in a J-EX8200 Switch The top monitoring or maintenance. A minor alarm that is left unchecked might cause interruption in service or performance degradation. All three LEDs can be lit simultaneously. Related • LCD
  • Dell PowerConnect J-8216 | Hardware Guide - Page 41
    Chapter 2: Component Descriptions Field-Replaceable Units in a J-EX8216 Switch Field-replaceable units (FRUs) are switch components that you can replace at your site. The J-EX8216 FRUs are hot-insertable and hot-removable: You can remove and replace them without powering off the switch or
  • Dell PowerConnect J-8216 | Hardware Guide - Page 42
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide • Removing a Transceiver from a J-EX Series Switch on page 168 Routing Engine (RE) Module in a J-EX8216 Switch The Routing Engine (RE) module performs system control, system
  • Dell PowerConnect J-8216 | Hardware Guide - Page 43
    27. • Recessed reset button-Power cycles the RE module when pressed. • USB port-Provides an interface through which you can install the Junos OS manually. See "USB Port Specifications for a J-EX Series Switch" on page 49. • Auxiliary port-This port is not enabled on J-EX8200 switches. It is reserved
  • Dell PowerConnect J-8216 | Hardware Guide - Page 44
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Figure 11: RE Module LEDs in a J-EX8216 Switch Table 14 on page 28 describes these LEDs, their colors and states, and the status they indicate.
  • Dell PowerConnect J-8216 | Hardware Guide - Page 45
    Chapter 2: Component Descriptions Management Port LEDs in J-EX8200 Switches The management port on J-EX8200 switches has two LEDs that indicate link/activity and port status (see Figure 12 on page 29). The management port is set to full-duplex and the speed is set to 100 Mbps. Figure 12: LEDs on the
  • Dell PowerConnect J-8216 | Hardware Guide - Page 46
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide A J-EX8216 switch can have up to eight SF modules. We recommend that you install all eight SF modules in a J-EX8216 switch to support maximum midplane performance for the installed line cards. All shipping configurations of a J-
  • Dell PowerConnect J-8216 | Hardware Guide - Page 47
    Chapter 2: Component Descriptions The SF modules contain logic that determines which RE module is the master. The master RE module controls many internal functions of the SF modules. The SF modules provide these functions: • Provide data path connectivity for the switch (switch data between line
  • Dell PowerConnect J-8216 | Hardware Guide - Page 48
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Table 17: SF Module LEDs in a J-EX8216 Switch LED (Description) Color State and Description ST (Status) Green Yellow • On steadily-SF module is operating normally. •
  • Dell PowerConnect J-8216 | Hardware Guide - Page 49
    -port SFP Line Card in a J-EX8200 Switch on page 33 Documentation • 48-port RJ-45 Line Card in a J-EX8200 Switch on page 34 • Optical Interface Support in J-EX8200 Switches on page 51 • Installing a Line Card in a J-EX8200 Switch on page 123 • Handling and Storing Line Cards in J-EX8200 Switches on
  • Dell PowerConnect J-8216 | Hardware Guide - Page 50
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Figure 16: 48-port SFP Line Card page 32 Documentation • 48-port RJ-45 Line Card in a J-EX8200 Switch on page 34 • Optical Interface Support in J-EX8200 Switches on page 51 • Installing a Line Card in a J-EX8200 Switch on page 123 •
  • Dell PowerConnect J-8216 | Hardware Guide - Page 51
    Figure 17: 48-port RJ-45 Line Card Chapter 2: Component Descriptions The line card has two status LEDs labeled ON and ST on the faceplate that indicate the online and status information for the line card. See "Line Card LEDs in a J-EX8200 Switch" on page 35. Related • 8-port SFP+ Line Card in a J-
  • Dell PowerConnect J-8216 | Hardware Guide - Page 52
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Figure 20: Status LEDs on 48-port RJ-45 Line Card Table 18 on page 36 describes the status LEDs on line cards for the J-
  • Dell PowerConnect J-8216 | Hardware Guide - Page 53
    Chapter 2: Component Descriptions Figure 21: Network Port LEDs on an 8-port SFP+ Line Card Figure 22 on page 37 shows the network port LEDs on a 48-port SFP line card. The LEDs point toward the port to which the LEDs belong. Figure 22: Network Port LEDs on a 48-port SFP Line Card Figure 23 on page
  • Dell PowerConnect J-8216 | Hardware Guide - Page 54
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Table 19: Network Port LEDs on Line Cards in a J-EX8200 Switch-Link/Activity LED LED Color State and Description Link/Activity Green • On steadily-The
  • Dell PowerConnect J-8216 | Hardware Guide - Page 55
    Chapter 2: Component Descriptions • Line Card LEDs in a J-EX8200 Switch on page 35 • LCD Panel in a J-EX8200 Switch on page 19 AC Power Supply in a J-EX8200 Switch This topic describes the AC power supplies in J-EX8200 switches: • AC Power Supply Description on page 39 • N+1 Redundancy Configuration
  • Dell PowerConnect J-8216 | Hardware Guide - Page 56
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide the power cord in the correct position. For instructions for installing the power retainer, see "Connecting AC switch supports both 2000 W AC power supplies and 3000 W AC power supplies. The 2000 W AC power supply supports both
  • Dell PowerConnect J-8216 | Hardware Guide - Page 57
    100-120 VAC) 2 3 Fully loaded with 8-port SFP+ line cards High line (200-240 VAC) 5 Low line (100-120 VAC) Not supported 6 Not supported Table 22: N+1 Power Redundancy Configurations for J-EX8216 Switch Configurations Using 3000 W AC Power Supplies Switch Configuration Input Voltage Power
  • Dell PowerConnect J-8216 | Hardware Guide - Page 58
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide redundancy configuration. For details about different switch (200-240 VAC) Low line (100-120 VAC) 5 Not supported Not supported Not supported Table 24: N+N Power Supply Requirements for J-EX8216 Switch Configurations Using 3000
  • Dell PowerConnect J-8216 | Hardware Guide - Page 59
    Chapter 2: Component Descriptions Figure 26: AC Power Supply LEDs on a J-EX8200 Switch Table 25 on page 43 describes the LEDs on an AC power supply in a J-EX8200 switch. Table 25: Power Supply LEDs on J-EX8200 Switches LED State Description INPUT OK Unlit Green Indicates one of the following
  • Dell PowerConnect J-8216 | Hardware Guide - Page 60
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide NOTE: If the INPUT OK LED and the OUTPUT OK LED are unlit, the AC power cord is not installed properly or the power supply
  • Dell PowerConnect J-8216 | Hardware Guide - Page 61
    Chapter 2: Component Descriptions Figure 27: Fan Tray for a J-EX8216 Switch The top and bottom fan trays are identical and interchangeable. Both fan trays can be removed and replaced from the front of the chassis. The switch continues to operate for a limited time (2 minutes) after a fan tray has
  • Dell PowerConnect J-8216 | Hardware Guide - Page 62
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Figure 28: Airflow Through the J-EX8216 Switch Chassis The air intake to cool the power supplies is located in the front of each power supply
  • Dell PowerConnect J-8216 | Hardware Guide - Page 63
    Chapter 2: Component Descriptions Figure 29: Airflow for the J-EX8216 Switch Chassis Rear NOTE: Do not block the air intake below the power supply slots. The Routing Engine (RE) module monitors the temperature of switch components. Under normal operating conditions, the fans in the fan trays run at
  • Dell PowerConnect J-8216 | Hardware Guide - Page 64
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide The fan trays continue to operate indefinitely and or any component connected to the midplane with any metallic object while you are servicing components installed in the switch. Related • Field-Replaceable Units in a J-EX8216
  • Dell PowerConnect J-8216 | Hardware Guide - Page 65
    the switch from a software package installed on a USB flash drive, see the the Dell PowerConnect J-Series Ethernet Switch Complete Software Guide for Junos OS at http://www.support.dell.com/manuals. Console Port Connector Pinout Information for a J-EX Series Switch The console port on a J-EX
  • Dell PowerConnect J-8216 | Hardware Guide - Page 66
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide NOTE: If your laptop or PC does not have management device for out-of-band management. The port uses an autosensing RJ-45 connector to support a 10/100/1000Base-T connection. Two LEDs on the port indicate link/activity on the port
  • Dell PowerConnect J-8216 | Hardware Guide - Page 67
    command does not give any output for copper transceivers, Fast Ethernet transceivers, or transceivers not purchased from Dell. The two tables in this topic describe the optical interface support over single-mode fiber-optic (SMF) and multimode fiber-optic (MMF) cables for SFP and SFP+ transceivers
  • Dell PowerConnect J-8216 | Hardware Guide - Page 68
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Table 28: Optical Interface Support for SFP+ Transceivers in 8-port SFP+ Line Cards Used in J-EX8200 Switches Ethernet Standard Specifications 10GBase-SR Model Number EX-SFP-10GE-SR Rate 10
  • Dell PowerConnect J-8216 | Hardware Guide - Page 69
    Chapter 3: Component Specifications Table 28: Optical Interface Support for SFP+ Transceivers in 8-port SFP+ Line Cards Used in J-EX8200 Switches (continued /km Distance 220 m (722 ft) 220 m (722 ft) 220 m (722 ft) DOM Support Available Software required Junos OS for J-EX Series switches 53
  • Dell PowerConnect J-8216 | Hardware Guide - Page 70
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Table 28: Optical Interface Support for SFP+ Transceivers in 8-port SFP+ Line Cards Used in J-EX8200 Switches (continued) Ethernet Standard Specifications 10GBase-LR Model Number EX-SFP-10GE-LR Rate
  • Dell PowerConnect J-8216 | Hardware Guide - Page 71
    Wavelength - Minimum Launch Power - Maximum Launch Power - Minimum Receiver Sensitivity - Maximum Input Power - Fiber Type Copper Core Size - Modal Bandwidth - Distance 100 m (328 ft) DOM Support Not available Software required Junos OS for J-EX Series switches 55
  • Dell PowerConnect J-8216 | Hardware Guide - Page 72
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Table 29: Optical Interface Support and Copper Interface Support for SFP Transceivers in 48-port SFP Line Cards Used in J-EX8200 Switches (continued) Ethernet Standard Specifications 1000Base-SX Model Number EX-SFP-1GE-SX
  • Dell PowerConnect J-8216 | Hardware Guide - Page 73
    Chapter 3: Component Specifications Table 29: Optical Interface Support and Copper Interface Support for SFP Transceivers in 48-port SFP Line MMF Core Size 62.5 µm Modal Bandwidth - Distance 2 km (1.2 miles) DOM Support Not available Software required Junos OS for J-EX Series switches 57
  • Dell PowerConnect J-8216 | Hardware Guide - Page 74
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Table 29: Optical Interface Support and Copper Interface Support for SFP Transceivers in 48-port SFP Line Cards Used in J-EX8200 Switches (continued) Ethernet Standard Specifications 1000Base-LX Model Number EX-SFP-1GE-LX
  • Dell PowerConnect J-8216 | Hardware Guide - Page 75
    Switch on page 34 • For show interfaces diagnostics optics command syntax, see the Dell PowerConnect J-Series Ethernet Switch Complete Software Guide for Junos OS at http://www.support.dell.com/manuals. • Installing a Transceiver in a J-EX Series Switch on page 126 • Removing a Transceiver from
  • Dell PowerConnect J-8216 | Hardware Guide - Page 76
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide J-EX8200 switch, connect a grounding cable to earth ground and then attach it to the chassis grounding points. CAUTION: For installations that require a separate grounding conductor
  • Dell PowerConnect J-8216 | Hardware Guide - Page 77
    PART 2 Planning for Switch Installation • Site Preparation on page 63 • Rack and Cabinet Requirements on page 69 • Cable Requirements on page 77 • Planning Power Requirements on page 81 61
  • Dell PowerConnect J-8216 | Hardware Guide - Page 78
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide 62
  • Dell PowerConnect J-8216 | Hardware Guide - Page 79
    CHAPTER 4 Site Preparation • Site Preparation Checklist for a J-EX8200 Switch on page 63 • General Site Guidelines for J-EX Series Switches on page 64 • Site Electrical Wiring Guidelines for J-EX Series Switches on page 65 • Environmental Requirements and Specifications for J-EX Series Switches on
  • Dell PowerConnect J-8216 | Hardware Guide - Page 80
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Table 30: Site Preparation Checklist (continued) Item or Task For More Information Performed By Date Rack or Cabinet Select the type of rack or cabinet
  • Dell PowerConnect J-8216 | Hardware Guide - Page 81
    Guidelines Site Wiring Factor Signaling limitations Radio frequency interference Guidelines If your site experiences any of the following problems, consult experts in electrical surge suppression and shielding: • Improperly installed wires cause radio frequency interference (RFI). • Damage from
  • Dell PowerConnect J-8216 | Hardware Guide - Page 82
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Table 31: Site Electrical Wiring Guidelines (continued) Site Wiring Factor Guidelines Electromagnetic compatibility If your site is susceptible to problems with electromagnetic compatibility (EMC), particularly from lightning or
  • Dell PowerConnect J-8216 | Hardware Guide - Page 83
    Chapter 4: Site Preparation Table 32: J-EX Series Switch Environmental Tolerances (continued) Description Tolerance Seismic Complies with Zone 4 earthquake requirements as per GR-63, Issue 3. NOTE: Install J-EX Series switches only in restricted areas, such as dedicated equipment rooms and
  • Dell PowerConnect J-8216 | Hardware Guide - Page 84
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide 68
  • Dell PowerConnect J-8216 | Hardware Guide - Page 85
    on page 73 Rack Requirements for a J-EX8216 Switch You can mount J-EX8216 switches on four-post racks. Two-post rack installation is not supported. Rack requirements consist of: • Rack type • Mounting bracket hole spacing • Rack size and strength • Rack connection to the building structure Table 33
  • Dell PowerConnect J-8216 | Hardware Guide - Page 86
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Table 33: Rack Requirements and of 44 U are required. In all cases, the rack must meet the strength requirements to support the weight of the switch. Rack size and strength Rack connection to the building structure • Ensure
  • Dell PowerConnect J-8216 | Hardware Guide - Page 87
    Chapter 5: Rack and Cabinet Requirements Figure 30: Installing a J-EX8216 Switch in a Four-Post Rack Related • Rack-Mounting and Cabinet-Mounting Warnings for J-EX Series Switches on page 215 Documentation • Cabinet Requirements and Specifications for a J-EX8216 Switch on page 71 • Chassis Physical
  • Dell PowerConnect J-8216 | Hardware Guide - Page 88
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Table 34: Cabinet Requirements and Specifications be installed only on a four-post rack or cabinet. Installation on a two-post rack is not supported. • The minimum cabinet size for accommodating a J-EX8216 switch is 23.62 in. (60 cm
  • Dell PowerConnect J-8216 | Hardware Guide - Page 89
    Chapter 5: Rack and Cabinet Requirements • Rack Requirements for a J-EX8216 Switch on page 69 • Chassis Physical Specifications of a J-EX8216 Switch on page 9 Clearance Requirements for Airflow and Hardware Maintenance for a J-EX8216 Switch When planning the site for installing a J-EX8216 switch,
  • Dell PowerConnect J-8216 | Hardware Guide - Page 90
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Figure 32: Airflow for the J-EX8216 on each side of the chassis. Leave adequate space at the front of the switch for service personnel to remove and install hardware components. NEBS GR-63 recommends that you allow at least 30
  • Dell PowerConnect J-8216 | Hardware Guide - Page 91
    Chapter 5: Rack and Cabinet Requirements Figure 33: Clearance Requirements for Airflow and Hardware Maintenance for a J-EX8216 Switch Chassis Related • Cooling System and Airflow in a J-EX8216 Switch on page 44 Documentation • Cabinet Requirements and Specifications for a J-EX8216 Switch on page 71
  • Dell PowerConnect J-8216 | Hardware Guide - Page 92
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide 76
  • Dell PowerConnect J-8216 | Hardware Guide - Page 93
    CHAPTER 6 Cable Requirements • Cables Connecting the J-EX8200 Switch to Management Devices on page 77 • Understanding J-EX8200 Switch Fiber-Optic Cable Signal Loss, Attenuation, and Dispersion on page 78 Cables Connecting the J-EX8200 Switch to Management Devices Table 35 on page 77 lists the
  • Dell PowerConnect J-8216 | Hardware Guide - Page 94
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Understanding J-EX8200 Switch Fiber-Optic Cable It is consequently more expensive. For information about the maximum transmission distance and supported wavelength range for the types of single-mode and multimode fiber-optic cables
  • Dell PowerConnect J-8216 | Hardware Guide - Page 95
    J-EX8200 Switch Fiber-Optic Cable Power Budget on page 91 Documentation • Calculating the J-EX8200 Switch Fiber-Optic Cable Power Margin on page 92 • Optical Interface Support in J-EX8200 Switches on page 51 79
  • Dell PowerConnect J-8216 | Hardware Guide - Page 96
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide 80
  • Dell PowerConnect J-8216 | Hardware Guide - Page 97
    CHAPTER 7 Planning Power Requirements • AC Power Specifications for J-EX8200 Switches on page 81 • Power Requirements for J-EX8216 Switch Components on page 82 • AC Power Cord Specifications for a J-EX8200 Switch on page 83 • Calculating Power Requirements for a J-EX8216 Switch on page 85 •
  • Dell PowerConnect J-8216 | Hardware Guide - Page 98
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Table 37: Power Specifications for a 3000 W AC Power Supply in a J-EX8216 Switch Item Specifications AC input voltage Operating range: • High line-200-240 VAC NOTE: Low-line input is not supported for 3000 W AC power supplies on
  • Dell PowerConnect J-8216 | Hardware Guide - Page 99
    Chapter 7: Planning Power Requirements AC Power Cord Specifications for a J-EX8200 Switch Each AC power supply has a single AC appliance inlet located on the power supply that requires a dedicated AC power feed. Sites can distribute power through a main conduit that leads to frame-mounted power
  • Dell PowerConnect J-8216 | Hardware Guide - Page 100
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Table 39: AC Power Cord Specifications for a J-EX8200 Switch (continued) Country/Region Electrical Specifications Plug Standards Israel 250 VAC, 16 A, 50 Hz IL/3, SI 32/
  • Dell PowerConnect J-8216 | Hardware Guide - Page 101
    Chapter 7: Planning Power Requirements CAUTION: AC power cords for J-EX8200 switches are intended for use with this switch only and not for any other use. Power Cable Warning (Japanese) WARNING: The attached power cable is only for this product. Do not use the cable for another product. CAUTION:
  • Dell PowerConnect J-8216 | Hardware Guide - Page 102
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide • Ensure that you know the power requirements of different switch components. See "Power Requirements for J-EX8216 Switch Components" on page 82. This topic describes these
  • Dell PowerConnect J-8216 | Hardware Guide - Page 103
    Chapter 7: Planning Power Requirements Table 41: Chassis Power Consumption for N+N Configurations Chassis Component Redundant Configuration Two fan trays 1000 W RE module 100 W Second RE module 100 W Eight SF modules 600 W Total 1800 W 2. Calculate the maximum internal power
  • Dell PowerConnect J-8216 | Hardware Guide - Page 104
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide To calculate the system thermal output: 1. Determine the maximum system power consumption of your switch in watts. See "Calculating the Power Consumption of Your J-EX8216
  • Dell PowerConnect J-8216 | Hardware Guide - Page 105
    Chapter 7: Planning Power Requirements To calculate the number of power supplies required for your switch configuration: 1. Determine the power requirement of the chassis-with the fan trays, RE modules, and SF modules, but no line cards-by consulting Table 42 on page 89. The watt values shown in
  • Dell PowerConnect J-8216 | Hardware Guide - Page 106
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide 3. Calculate the required number of power supplies (N) needed to meet the total power requirement by dividing the total power requirement by the output wattage of
  • Dell PowerConnect J-8216 | Hardware Guide - Page 107
    if the number of online power supplies in your switch is less than the number required to maintain the configured power redundancy (N+1 or N+N). If the problem is not corrected in 5 minutes, a major alarm is issued. Power management raises a major alarm if the number of online power supplies in your
  • Dell PowerConnect J-8216 | Hardware Guide - Page 108
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide -15 dBm - (-28 dBm) = 13 dBm Related • Calculating the J-EX8200 Switch Fiber-Optic Cable Power Margin on page 92 Documentation • Optical Interface Support in J-EX8200 Switches on page 51 • Understanding J-EX8200 Switch Fiber-Optic
  • Dell PowerConnect J-8216 | Hardware Guide - Page 109
    the maximum receiver input power. Related • Calculating the J-EX8200 Switch Fiber-Optic Cable Power Budget on page 91 Documentation • Optical Interface Support in J-EX8200 Switches on page 51 • Understanding J-EX8200 Switch Fiber-Optic Cable Signal Loss, Attenuation, and Dispersion on page 78 93
  • Dell PowerConnect J-8216 | Hardware Guide - Page 110
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide 94
  • Dell PowerConnect J-8216 | Hardware Guide - Page 111
    PART 3 Installing and Connecting the Switch and Switch Components • Installing the Switch on page 97 • Installing Switch Components on page 113 • Connecting the Switch on page 129 • Performing Initial Configuration on page 143 95
  • Dell PowerConnect J-8216 | Hardware Guide - Page 112
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide 96
  • Dell PowerConnect J-8216 | Hardware Guide - Page 113
    "Connecting and Configuring a J-EX Series Switch (J-Web Procedure)" on page 146. To connect the switch to a network for out-of-band management, follow instructions in "Connecting a J-EX Series Switch to a Network for Out-of-Band Management" on page 135. To connect the switch to a management console
  • Dell PowerConnect J-8216 | Hardware Guide - Page 114
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Related • Rack Requirements for a J-EX8216 Switch on page 69 Documentation • Cabinet Requirements and Specifications for a J-EX8216 Switch on page 71 • Clearance Requirements for Airflow and
  • Dell PowerConnect J-8216 | Hardware Guide - Page 115
    Figure 35: Pallet Fastener Chapter 8: Installing the Switch 4. Carefully slice open the tape that holds the top of the cardboard box closed and open the top of the box. 5. Remove the cardboard accessory box from the center of the foam padding. 6. Remove the foam padding from the top of the box. 7.
  • Dell PowerConnect J-8216 | Hardware Guide - Page 116
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Figure 36: Unpacking a J-EX8216 Switch Shipping box Packing material, power cords, and accessories Switch Shipping pallet Pallet fasteners (4) Related • Mounting a J-EX8216 Switch on a Rack or
  • Dell PowerConnect J-8216 | Hardware Guide - Page 117
    page 7 for more information. If you have a problem with your order, such as missing parts, wrong parts, or incorrect billing, contact Dell for customer assistance. Have your invoice or packing slip , accessories contents Accessory kit box Quick Start installation instructions Quantity 1 1 1 101
  • Dell PowerConnect J-8216 | Hardware Guide - Page 118
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Table 45: Accessory Box Parts List (continued) Component License Agreement 1 DellPowerConnect Warranty and Support Information 1 Registration and Software Updates for Your Dell PowerConnect J-Series Product 1 Open Source Code
  • Dell PowerConnect J-8216 | Hardware Guide - Page 119
    of this topic uses "rack" to mean "rack or cabinet.") The J-EX8200 switch comes with a four-piece set of adjustable mounting brackets that supports the chassis in the rack. The four adjustable mounting bracket pieces are: • 1 left front adjustable mounting bracket. The bracket is labeled "LEFT FRONT
  • Dell PowerConnect J-8216 | Hardware Guide - Page 120
    g040637 Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide When you install the adjustable mounting brackets, the "arms" of the brackets overlap. The overlap area adjusts the total bracket length to fit three standard
  • Dell PowerConnect J-8216 | Hardware Guide - Page 121
    Chapter 8: Installing the Switch 8. Connect left front and rear brackets (see Figure 39 on page 105): a. Insert 6 of the screws provided with the mounting brackets into the overlapping bracket holes. b. Hand tighten the screws fully (to 12-16 in.-lb torque) using a number 2 Phillips screwdriver.
  • Dell PowerConnect J-8216 | Hardware Guide - Page 122
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide 13. Use 4 mounting screws appropriate for your rack-plus in a four-post rack. Installation in a two-post rack is not supported. The power cord tray provides a place to organize and tie down the power cords for the power supplies. 106
  • Dell PowerConnect J-8216 | Hardware Guide - Page 123
    69 and "Cabinet Requirements and Specifications for a J-EX8216 Switch" on page 71. NOTE: Installation of a J-EX8216 switch in a two-post rack is not supported. 3. If your rack has unthreaded round or square holes, install 4 cage nuts in the appropriate holes on the right and left front rack posts
  • Dell PowerConnect J-8216 | Hardware Guide - Page 124
    g040639 Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Figure 42: Installing a Square-Hole uses "rack" to mean "rack or cabinet.") The switch also comes with adjustable mounting brackets to support it in the rack. In a four-post rack, the switch consumes 21 U without the optional
  • Dell PowerConnect J-8216 | Hardware Guide - Page 125
    Chapter 8: Installing the Switch WARNING: Because of the switch's size and weight, we require the use of a mechanical lift to install the switch. CAUTION: If you are installing more than one switch in a rack, install the first switch at the bottom of the rack. CAUTION: Do not install line cards in
  • Dell PowerConnect J-8216 | Hardware Guide - Page 126
    g040637 Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide 1. Install the adjustable mounting brackets at the desired position in a four-post rack (see "Installing Adjustable Mounting Brackets in a Rack or Cabinet for a J-EX8200 Switch"
  • Dell PowerConnect J-8216 | Hardware Guide - Page 127
    chassis in the rack as close as possible to resting on the support that the mounting brackets provide. 6. Carefully slide the switch onto the posts, using the handles on the lower side of the chassis to help guide it into position. The adjustable mounting brackets installed in the rack ensure that
  • Dell PowerConnect J-8216 | Hardware Guide - Page 128
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide 10. Visually inspect the alignment two protective earthing terminals on the switch chassis to connect to the earth ground. For instructions on connecting a J-EX8200 switch to ground using a separate grounding conductor, see "
  • Dell PowerConnect J-8216 | Hardware Guide - Page 129
    CHAPTER 9 Installing Switch Components • Installing and Removing J-EX8216 Switch Hardware Components on page 113 • Installing an AC Power Supply in a J-EX8200 Switch on page 114 • Installing a Fan Tray in a J-EX8216 Switch on page 116 • Installing an RE Module in a J-EX8216 Switch on page 118 •
  • Dell PowerConnect J-8216 | Hardware Guide - Page 130
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide To install an RE module in a J-EX8216 switch, follow instructions in "Installing an RE Module in a J-EX8216 Switch" on page 118. To remove an RE module, follow instructions in "Removing an RE Module from a J-EX8216 Switch" on page
  • Dell PowerConnect J-8216 | Hardware Guide - Page 131
    Chapter 9: Installing Switch Components To install an AC power supply in a J-EX8200 switch (see Figure 48 on page 116): 1. Attach the electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to the ESD point on the chassis. 2. If the power supply slot has a cover panel
  • Dell PowerConnect J-8216 | Hardware Guide - Page 132
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Figure 48: Installing an AC Power Supply in a J-EX8200 Switch Related • Removing an AC Power Supply from a J-EX8200 Switch on page 157 Documentation • Calculating Power
  • Dell PowerConnect J-8216 | Hardware Guide - Page 133
    the ESD point on the chassis. 2. Hold the handle of the fan tray with one hand and support the weight of the tray with the other hand. Align the tray with the fan tray guides on the fan tray slot. Slide in the fan tray until it is fully seated in the
  • Dell PowerConnect J-8216 | Hardware Guide - Page 134
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide NOTE: Both fan trays must be installed in the chassis CAUTION: Do not lift the RE module by holding the ejector levers. The levers cannot support the weight of the module. Lifting the modules by the levers might bend the levers, and
  • Dell PowerConnect J-8216 | Hardware Guide - Page 135
    Chapter 9: Installing Switch Components 5. Carefully align the sides of the RE module with the guides inside the chassis. 6. Ensuring that the RE module is correctly aligned, carefully slide it into the chassis until you feel resistance. 7. Push both the ejector
  • Dell PowerConnect J-8216 | Hardware Guide - Page 136
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Installing an SF Module in a J-EX8216 Switch You can install NOTE: Do not lift the SF module by holding the ejector levers. The levers cannot support the weight of the module. Lifting the module by the levers might bend the levers.
  • Dell PowerConnect J-8216 | Hardware Guide - Page 137
    Chapter 9: Installing Switch Components Ensure the ejector levers are engaged in the horizontal ejector rail. If the levers are not engaged, push the module's faceplate just inside the hinges of the levers till the ejectors are engaged in the ejector rail. 6. Push both the ejector levers
  • Dell PowerConnect J-8216 | Hardware Guide - Page 138
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Figure 51: Installing an SF Module in a J-EX8216 Switch Related • Switch Fabric (SF) Modules in a J-EX8216 Switch on page 29 Documentation • SF Module LEDs in a J-
  • Dell PowerConnect J-8216 | Hardware Guide - Page 139
    Chapter 9: Installing Switch Components • Ensure that you know how to handle and store the line card (see "Handling and Storing Line Cards in J-EX8200 Switches" on page 175). To unpack a line card (see Figure 52 on page 123): 1. Move the shipping carton to a staging area as close to the installation
  • Dell PowerConnect J-8216 | Hardware Guide - Page 140
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide card, remove them before you install the line card. For instructions on removing transceivers, see "Removing a Transceiver from a faceplate or the edge connectors. The levers cannot support the weight of the line card. Lifting the
  • Dell PowerConnect J-8216 | Hardware Guide - Page 141
    the faceplate of the line card and the other hand under the line card to support it. CAUTION: The line cards in J-EX8200 switches weigh more than 10 lb the faceplate facing you and the sides of the line card aligned with the guides in the line card slot on the switch chassis. 7. Using both hands,
  • Dell PowerConnect J-8216 | Hardware Guide - Page 142
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Related • Removing a Line Card from a J-EX8200 Switch on disrupting switch functions. Use only optical transceivers and optical connectors purchased from Dell for your J-EX Series switch. Before you begin installing a transceiver in
  • Dell PowerConnect J-8216 | Hardware Guide - Page 143
    from a J-EX Series Switch on page 168 Documentation • Connecting a Fiber-Optic Cable to a J-EX Series Switch on page 127 • Optical Interface Support in J-EX8200 Switches on page 51 Connecting a Fiber-Optic Cable to a J-EX Series Switch J-EX Series switches have field-replaceable unit (FRU) optical
  • Dell PowerConnect J-8216 | Hardware Guide - Page 144
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide cable 4. Secure the cables so that they are not supporting their own weight. Place excess cable out of the way a few inches in diameter can damage the cables and cause problems that are difficult to diagnose. Do not let fiber-optic
  • Dell PowerConnect J-8216 | Hardware Guide - Page 145
    CHAPTER 10 Connecting the Switch • Connecting Earth Ground to a J-EX Series Switch on page 129 • Connecting AC Power to a J-EX8200 Switch on page 131 • Powering On a J-EX8200 Switch on page 133 • Connecting a J-EX Series Switch to a Network for Out-of-Band Management on page 135 • Connecting a J-EX
  • Dell PowerConnect J-8216 | Hardware Guide - Page 146
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide CAUTION: Using a grounding cable with an incorrectly attached lug can damage the switch. Follow the procedure that applies to your switch: • Connecting Earth Ground to a J-
  • Dell PowerConnect J-8216 | Hardware Guide - Page 147
    Mixing different types of power supplies in the same chassis is not a supported configuration. NOTE: Each power supply must be connected to a dedicated AC the J-EX8200 switch chassis to connect to the earth ground. For instructions on connecting a J-EX8200 switch to ground using a separate grounding
  • Dell PowerConnect J-8216 | Hardware Guide - Page 148
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide WARNING: Ensure that the power cords do not block access to switch components or drape where people can trip on them. To connect AC power
  • Dell PowerConnect J-8216 | Hardware Guide - Page 149
    on the switch, ensure that: • You have installed all required switch components. • You have installed the required number of power supplies to support redundant operation for the switch configuration (see "Calculating Power Requirements for a J-EX8216 Switch" on page 85). • You understand how to
  • Dell PowerConnect J-8216 | Hardware Guide - Page 150
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide For connecting a management device to the console port, see "Connecting a J-EX Series Switch to a Management Console" on page 136. For connecting a management device to the
  • Dell PowerConnect J-8216 | Hardware Guide - Page 151
    Chapter 10: Connecting the Switch NOTE: After you power on a power supply, wait for at least 60 seconds before you turn it off. After you power off a power supply, wait for at least 60 seconds before you turn it back on. If the system is completely powered off when you switch on a power supply, the
  • Dell PowerConnect J-8216 | Hardware Guide - Page 152
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Figure 62: Connecting a J-EX Series Switch to a Network for Out-of-Band Management Related • Connecting a J-EX Series Switch to a Management Console on page 136 Documentation •
  • Dell PowerConnect J-8216 | Hardware Guide - Page 153
    Chapter 10: Connecting the Switch To connect a J-EX Series switch to a management console (see Figure 64 on page 137 and Figure 65 on page 137): 1. Connect one end of the Ethernet cable into the console port (labeled CON or CONSOLE) on the J-EX Series switch. For the location of the CON/CONSOLE port
  • Dell PowerConnect J-8216 | Hardware Guide - Page 154
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide • A modem (not provided) • A desktop or notebook computer (not provided) • An RJ-45 to DB-9 adapter and an Ethernet cable (provided) • A phone cable (not provided) • If
  • Dell PowerConnect J-8216 | Hardware Guide - Page 155
    Chapter 10: Connecting the Switch Press Enter. The serial console speed is now set to 115200 baud. 6. Boot the software: loader> boot The boot process proceeds as normal and ends with a login prompt. Configuring the Modem Before you connect the modem, you must configure the modem with required port
  • Dell PowerConnect J-8216 | Hardware Guide - Page 156
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide 8. To disable flow control on the modem, type at&k0 at the prompt. Press Enter. 9. To set the fixed serial port speed on the modem,
  • Dell PowerConnect J-8216 | Hardware Guide - Page 157
    Chapter 10: Connecting the Switch 5. Connect the serial port adapter to the DB-9 female to DB-25 male adapter or other adapter appropriate for your modem. 6. Plug the modem adapter into the DB-25 connector on the modem. 7. Connect one end of the phone cable to the modem and the other end to your
  • Dell PowerConnect J-8216 | Hardware Guide - Page 158
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide 142
  • Dell PowerConnect J-8216 | Hardware Guide - Page 159
    can always revert to the factory default configuration. For instructions for reverting to the factory configuration, see the Dell PowerConnect J-Series Ethernet Switch Complete Software Guide for Junos OS at http://www.support.dell.com/manuals. This topic shows the factory default configuration file
  • Dell PowerConnect J-8216 | Hardware Guide - Page 160
    about J-EX Series switch configuration files and interfaces and instructions for reverting to the factory default configuration, see the Dell PowerConnect J-Series Ethernet Switch Complete Software Guide for Junos OS at http://www.support.dell.com/manuals. • J-EX8216 Switch Hardware Overview on page
  • Dell PowerConnect J-8216 | Hardware Guide - Page 161
    . You are prompted to re-enter the root password. 5. Enter yes to enable services like Telnet and SSH. By default, Telnet is not enabled and SSH is enabled . If the connection cannot be made, the J-Web interface displays instructions for starting a J-Web session. Related • Connecting and Configuring
  • Dell PowerConnect J-8216 | Hardware Guide - Page 162
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Connecting and Configuring a J-EX Series Switch (J-Web Procedure) There are two ways to connect and configure a J-EX Series switch: one method is through the console
  • Dell PowerConnect J-8216 | Hardware Guide - Page 163
    switch with the management PC or set them manually by selecting the appropriate option button. This select options to enable Telnet, SSH, and SNMP services. For SNMP, you can configure the read community, cannot be made, the J-Web interface displays instructions for starting a J-Web session. NOTE:
  • Dell PowerConnect J-8216 | Hardware Guide - Page 164
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide 148
  • Dell PowerConnect J-8216 | Hardware Guide - Page 165
    PART 4 Removing the Switch and Switch Components • Removing the Switch on page 151 • Removing Switch Components on page 157 149
  • Dell PowerConnect J-8216 | Hardware Guide - Page 166
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide 150
  • Dell PowerConnect J-8216 | Hardware Guide - Page 167
    CHAPTER 12 Removing the Switch • Powering Off a J-EX8200 Switch on page 151 • Removing a J-EX8216 Switch from a Rack or Cabinet on page 152 Powering Off a J-EX8200 Switch Before you power off the switch: • Ensure that you understand how to prevent electrostatic discharge damage. See "Prevention of
  • Dell PowerConnect J-8216 | Hardware Guide - Page 168
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide the switch gracefully and preserves system to reboot" message. Wait at least 60 seconds after first seeing this message before following the instructions in Step 5 to power off the switch. 4. Attach the ESD grounding strap to your
  • Dell PowerConnect J-8216 | Hardware Guide - Page 169
    Chapter 12: Removing the Switch WARNING: Because of the switch's size and weight, we require the use of a mechanical lift to remove the switch. NOTE: If you are removing more than one switch in a rack, remove the first switch from the top of the rack. Before removing a J-EX8216 switch from a rack: •
  • Dell PowerConnect J-8216 | Hardware Guide - Page 170
    g040638 g040635 Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Use Figure 68 on page 154 or Figure 69 on page 154 to help you with cage-nut removal. Figure 68: Removing a Round-Hole Cage
  • Dell PowerConnect J-8216 | Hardware Guide - Page 171
    Chapter 12: Removing the Switch Figure 70: Removing a Switch Chassis Using a Mechanical Lift Related • Mounting a J-EX8216 Switch on a Rack or Cabinet on page 108 Documentation 155
  • Dell PowerConnect J-8216 | Hardware Guide - Page 172
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide 156
  • Dell PowerConnect J-8216 | Hardware Guide - Page 173
    CHAPTER 13 Removing Switch Components • Removing an AC Power Supply from a J-EX8200 Switch on page 157 • Removing a Fan Tray from a J-EX8216 Switch on page 159 • Taking the RE Module Offline in a J-EX8216 Switch on page 161 • Removing an RE Module from a J-EX8216 Switch on page 163 • Taking the SF
  • Dell PowerConnect J-8216 | Hardware Guide - Page 174
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide CAUTION: Do not leave the power supply supply components, pins, leads, or solder connections, place one hand under the power supply to support it. Grasp the power supply handle with your other hand and pull the power supply completely
  • Dell PowerConnect J-8216 | Hardware Guide - Page 175
    Chapter 13: Removing Switch Components Figure 71: Removing an AC Power Supply from a J-EX8200 Switch Related • Installing an AC Power Supply in a J-EX8200 Switch on page 114 Documentation • AC Power Supply in a J-EX8200 Switch on page 39 Removing a Fan Tray from a J-EX8216 Switch A J-EX8216 switch
  • Dell PowerConnect J-8216 | Hardware Guide - Page 176
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide CAUTION: The fan trays can be removed and replaced while the switch is the fans to stop spinning. 5. Release the latch and use that hand to support the weight of the fan tray. Slide the fan tray completely out of the chassis. 160
  • Dell PowerConnect J-8216 | Hardware Guide - Page 177
    Chapter 13: Removing Switch Components Figure 72: Removing a Fan Tray from a J-EX8216 Switch Related • Installing a Fan Tray in a J-EX8216 Switch on page 116 Documentation • Cooling System and Airflow in a J-EX8216 Switch on page 44 • Field-Replaceable Units in a J-EX8216 Switch on page 25 Taking
  • Dell PowerConnect J-8216 | Hardware Guide - Page 178
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide 1. Determine whether the RE module is the master or backup using one of these methods: • Look at the MS (master) LED on the RE module
  • Dell PowerConnect J-8216 | Hardware Guide - Page 179
    lift the RE module by holding the ejector levers. The levers cannot support the weight of the module. Lifting the module by the levers might leads, pins, or solder connections, place one hand underneath the RE module to support it and slide it completely out of the chassis. 8. Place the RE module
  • Dell PowerConnect J-8216 | Hardware Guide - Page 180
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Figure 73: Removing an RE Module from a J-EX8216 Switch Related • Installing an RE Module in a J-EX8216 Switch on page 118 Documentation • Routing Engine (RE) Module
  • Dell PowerConnect J-8216 | Hardware Guide - Page 181
    SF modules be installed in the chassis at all times. NOTE: Do not lift the SF module by holding the ejector levers. The levers cannot support the weight of the module. Lifting the modules by the levers might bend the levers. Bent levers will prevent the SF module from being properly
  • Dell PowerConnect J-8216 | Hardware Guide - Page 182
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide 6. Grasp the handle on the faceplate of the SF module with one hand and pull the SF module to about halfway out. 7. Taking care not
  • Dell PowerConnect J-8216 | Hardware Guide - Page 183
    of the chassis. CAUTION: Do not lift the line card by holding the ejector levers on the faceplate or the edge connectors. The levers cannot support the weight of the line card. Lifting the line cards by the levers might bend them. Bent levers prevent the line cards from being properly
  • Dell PowerConnect J-8216 | Hardware Guide - Page 184
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide CAUTION: Do not stack line cards on top one hand around the faceplate of the line card and the other hand under the line card to support it. Taking care not to touch line card components, pins, leads, or solder connections, gently
  • Dell PowerConnect J-8216 | Hardware Guide - Page 185
    bend fiber-optic cables beyond their minimum bend radius. An arc smaller than a few inches in diameter can damage the cables and cause problems that are difficult to diagnose. 3. Remove the cable connected to the transceiver (see "Disconnecting a Fiber-Optic Cable from a J-EX Series Switch" on page
  • Dell PowerConnect J-8216 | Hardware Guide - Page 186
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide 6. Grasp the transceiver ejector lever and gently slide the a Transceiver in a J-EX Series Switch on page 126 Documentation • Optical Interface Support in J-EX8200 Switches on page 51 Disconnecting a Fiber-Optic Cable from a J-EX
  • Dell PowerConnect J-8216 | Hardware Guide - Page 187
    "rack" to mean "rack or cabinet.") NOTE: The J-EX8216 switch can be installed only in a four-post rack. Installation in a two-post rack is not supported. Before you begin to remove the power cord tray: • Ensure no power cables are resting on or threaded through the power cord tray. Ensure that
  • Dell PowerConnect J-8216 | Hardware Guide - Page 188
    g040638 Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide • If you installed the power cord tray with square-hole cage nuts, a flat-blade (-) screwdriver to remove the cage nuts To remove the power cord
  • Dell PowerConnect J-8216 | Hardware Guide - Page 189
    PART 5 Switch and Component Maintenance • Routine Maintenance on page 175 173
  • Dell PowerConnect J-8216 | Hardware Guide - Page 190
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide 174
  • Dell PowerConnect J-8216 | Hardware Guide - Page 191
    CHAPTER 14 Routine Maintenance • Handling and Storing Line Cards in J-EX8200 Switches on page 175 • Maintaining Line Card Cables in J-EX8200 Switches on page 178 • Maintaining Fiber-Optic Cables in J-EX Series Switches on page 179 Handling and Storing Line Cards in J-EX8200 Switches Components in
  • Dell PowerConnect J-8216 | Hardware Guide - Page 192
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Holding a Line Card You must hold a line card horizontally when installing it in the chassis. You may hold a line card vertically or horizontally when carrying
  • Dell PowerConnect J-8216 | Hardware Guide - Page 193
    Chapter 14: Routine Maintenance Figure 81: Do Not Grasp the Connector Edge Never carry the line card while holding the faceplate with only one hand. Do not rest any edge of a line card directly against a hard surface (see Figure 82 on page 177). Figure 82: Do Not Rest the Edge of a Line Card on a
  • Dell PowerConnect J-8216 | Hardware Guide - Page 194
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Do not stack line cards on top of one another or on . To extend the lives of your line card cables and to avoid problems that can result from cable damage, follow these procedures: To maintain line card cables in J-EX8200 switches:
  • Dell PowerConnect J-8216 | Hardware Guide - Page 195
    a transceiver, be sure to secure the fiber-optic cable so that it is not supporting its own weight as it hangs to the floor. Never let a fiber-optic cable than a few inches in diameter can damage the cables and cause problems that are difficult to diagnose. • Frequent plugging and unplugging of
  • Dell PowerConnect J-8216 | Hardware Guide - Page 196
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Related • Handling and Storing Line Cards in J-EX8200 Switches on page 175 Documentation • Safety Guidelines and Warnings for J-EX Series Switches on page 207 • Optical Interface Support in J-EX8200 Switches on page 51 180
  • Dell PowerConnect J-8216 | Hardware Guide - Page 197
    PART 6 Returning Hardware • Getting Help on page 183 181
  • Dell PowerConnect J-8216 | Hardware Guide - Page 198
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide 182
  • Dell PowerConnect J-8216 | Hardware Guide - Page 199
    of online services available at Dell Support (http://www.support.dell.com) for help with installation and troubleshooting procedures. See "Online Services" on page 184 for a more extensive list of Dell Support 3. If the preceding steps have not resolved the problem, see "Contacting Dell" on page
  • Dell PowerConnect J-8216 | Hardware Guide - Page 200
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Online Services When prompted by Dell's automated telephone system, enter your Express Service Code to route the call directly to the proper support personnel. For instructions on using the Dell Support, see "Support Service" on
  • Dell PowerConnect J-8216 | Hardware Guide - Page 201
    Dell" on page 187. Support Service Dell's support service is available 24 hours a day, 7 days a week, to answer your questions about Dell hardware. Our support by the Dell Diagnostics. 4. Include any accessories that belong with the item(s) being returned (such as power cables and guides) if the
  • Dell PowerConnect J-8216 | Hardware Guide - Page 202
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Before You Call You are responsible for paying shipping expenses. You are also responsible for insuring any product returned, and you assume the risk of loss during shipment to Dell. Collect On Delivery (C.O.D.) packages are not
  • Dell PowerConnect J-8216 | Hardware Guide - Page 203
    each file. Otherwise, record the contents of each file before calling Dell. Error message, beep code, or diagnostic code: Description of problem and troubleshooting procedures you performed: For customers in the United States, call 800-WWW.DELL (800.999.3355). NOTE: If you do not have an active
  • Dell PowerConnect J-8216 | Hardware Guide - Page 204
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Locating the Serial Number on a J-EX8200 Switch or Component To list BG0709251729 BG0709251737 CX1209110149 CX1209110149 CX1209110121 CX1209110121 CE0109020194 Description DELL J-EX8216 EX8216-MP EX8216-RE320 RE-EX8216 EX8216
  • Dell PowerConnect J-8216 | Hardware Guide - Page 205
    Chapter 15: Getting Help Figure 83: Location of the Serial Number ID Label on J-EX8216 Switch Chassis Locating the Serial Number ID Labels on FRUs in a J-EX8200 Switch The power supplies, fan tray, SRE modules, RE modules, SF module, and line cards installed in a J-EX8200 switch are field-
  • Dell PowerConnect J-8216 | Hardware Guide - Page 206
    g020535 Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide • 2000 W AC power supply-The serial number ID label is on the left side of the power supply (see Figure 84 on page 190). See "
  • Dell PowerConnect J-8216 | Hardware Guide - Page 207
    Chapter 15: Getting Help • Fan trays in a J-EX8216 switch-The serial number ID label is on the rear of each fan tray (see Figure 86 on page 191). See "Removing a Fan Tray from a J-EX8216 Switch" on page 159. Figure 86: Location of the Serial Number ID label on the Fan Tray Used in a J-EX8216 Switch
  • Dell PowerConnect J-8216 | Hardware Guide - Page 208
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Figure 88: Location of the Serial Number ID Label on the SF Module Used in a J-EX8216 Switch • 8-port SFP+ line card-See Figure 89 on
  • Dell PowerConnect J-8216 | Hardware Guide - Page 209
    or component, ensure that you: • Have retrieved the original shipping carton and packing materials. If you do not have these materials, contact Dell to learn about approved packing materials. See "Returning Items for Warranty Repair or Credit" on page 185. • Ensure you understand how to prevent
  • Dell PowerConnect J-8216 | Hardware Guide - Page 210
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide This topic describes: • Packing a J-EX8216 Switch for Shipping on page 194 • Packing J-EX8216 Switch Components for Shipping on page 196 • Packing a Line Card Used in a J-
  • Dell PowerConnect J-8216 | Hardware Guide - Page 211
    the pallet so that the front of the switch is facing the silkscreened "front" mark on the pallet. The pallet also has crop marks to guide you in positioning the chassis. 3. Use the 7/16-in. or 11-mm open-end or socket wrench to install the four sets of brackets and
  • Dell PowerConnect J-8216 | Hardware Guide - Page 212
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide See "Returning Items for Warranty Repair or Credit" on page 185. Figure 93: Packing a J-EX8200 Switch Packing J-EX8216 Switch Components for Shipping To pack J-EX8200 switch components, follow the instructions here. For instructions
  • Dell PowerConnect J-8216 | Hardware Guide - Page 213
    during transit. The packing material you use must be able to support the weight of the component. • Ensure that the components are carton and packing materials. If you do not have these materials, contact Dell to learn about approved packing materials. See "Returning Items for Warranty Repair
  • Dell PowerConnect J-8216 | Hardware Guide - Page 214
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide To pack a line card: 1. Place the line card in Card from a J-EX8200 Switch on page 166 Dell Support If you need assistance while troubleshooting a switch, please go to the Dell Support website at http://www.support.dell.com. 198
  • Dell PowerConnect J-8216 | Hardware Guide - Page 215
    PART 7 Safety Information • General Safety Information on page 201 • Radiation and Laser Warnings on page 207 • Installation and Maintenance Safety Information on page 213 • Power and Electrical Safety Information on page 229 199
  • Dell PowerConnect J-8216 | Hardware Guide - Page 216
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide 200
  • Dell PowerConnect J-8216 | Hardware Guide - Page 217
    times. • Perform only the procedures explicitly described in the hardware documentation for this product. Make sure that only authorized service personnel perform other system services. • Keep the area around the chassis clear and free from dust before, during, and after installation. • Keep tools
  • Dell PowerConnect J-8216 | Hardware Guide - Page 218
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide • Replace fuses only with fuses of the same type and rating. • Do not open or remove chassis covers or sheet-metal parts unless instructions are provided in the hardware documentation for this product. Such an action could cause
  • Dell PowerConnect J-8216 | Hardware Guide - Page 219
    infortuni alle persone. Prima di lavorare su qualsiasi apparecchiatura, occorre conoscere i pericoli relativi ai circuiti elettrici ed essere al corrente delle pratiche standard per la prevenzione di incidenti. WARNING: Advarsel Dette varselsymbolet betyr fare. Du befinner deg i en situasjon som kan
  • Dell PowerConnect J-8216 | Hardware Guide - Page 220
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide WARNING: Aviso Este símbolo de aviso indica perigo. Safety Guidelines and Warnings for J-EX Series Switches on page 201 • Installation Instructions Warning for J-EX Series Switches on page 213 • Maintenance and Operational Safety
  • Dell PowerConnect J-8216 | Hardware Guide - Page 221
    or near a switch running Junos OS. If a dry chemical fire extinguisher is used, the unit is no longer eligible for coverage under a service agreement. We recommend that you dispose of any irreparably damaged equipment in an environmentally responsible manner. Related • General Safety Guidelines and
  • Dell PowerConnect J-8216 | Hardware Guide - Page 222
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Attention Tout installation ou remplacement de l'appareil doit être réalisé par du personnel qualifié et compétent. Warnung Gerät nur von geschultem, qualifiziertem Personal installieren
  • Dell PowerConnect J-8216 | Hardware Guide - Page 223
    • Class 1 LED Product Warning on page 208 • Laser Beam Warning on page 208 General Laser Safety Guidelines When working around ports that support optical transceivers, observe the following safety guidelines to prevent eye injury: • Do not look into unterminated ports or at fibers that connect to
  • Dell PowerConnect J-8216 | Hardware Guide - Page 224
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Waarschuwing Klasse-1 laser produkt. Varoitus Luokan 1 lasertuote. Attention Produit laser de classe I. Warnung Laserprodukt der Klasse 1. WARNING: Avvertenza Prodotto laser di Classe 1. Advarsel Laserprodukt av
  • Dell PowerConnect J-8216 | Hardware Guide - Page 225
    Warnings for J-EX Series Switches on page 201 Documentation • Radiation from Open Port Apertures Warning for J-EX Series Switches on page 210 • Installation Instructions Warning for J-EX Series Switches on page 213 • Grounded Equipment Warning for J-EX Series Switches on page 219 • Optical Interface
  • Dell PowerConnect J-8216 | Hardware Guide - Page 226
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Radiation from Open Port Apertures Warning for J-EX Series Switches WARNING: Because invisible radiation might be emitted from the aperture of the port when no
  • Dell PowerConnect J-8216 | Hardware Guide - Page 227
    and Warnings for J-EX Series Switches on page 201 Documentation • Laser and LED Safety Guidelines and Warnings for J-EX Series Switches on page 207 • Installation Instructions Warning for J-EX Series Switches on page 213 • Grounded Equipment Warning for J-EX Series Switches on page 219 211
  • Dell PowerConnect J-8216 | Hardware Guide - Page 228
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide 212
  • Dell PowerConnect J-8216 | Hardware Guide - Page 229
    and Operational Safety Guidelines and Warnings for J-EX Series Switches on page 220 Installation Instructions Warning for J-EX Series Switches WARNING: Read the installation instructions before you connect the switch to a power source. Waarschuwing Raadpleeg de installatie-aanwijzingen voordat
  • Dell PowerConnect J-8216 | Hardware Guide - Page 230
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Varning! Läs installationsanvisningarna innan du Safety Guidelines and Warnings for J-EX Series Switches on page 201 Documentation • Installation Instructions Warning for J-EX Series Switches on page 213 • Mounting a J-EX8216 Switch
  • Dell PowerConnect J-8216 | Hardware Guide - Page 231
    and Warnings for J-EX Series Switches on page 207 • Installation Instructions Warning for J-EX Series Switches on page 213 • Grounded Equipment securely supported. Uneven mechanical loading could lead to a hazardous condition. WARNING: To prevent bodily injury when mounting or servicing the switch
  • Dell PowerConnect J-8216 | Hardware Guide - Page 232
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide • De switch moet in een stellage worden geïnstalleerd die aan een bouwsel is verankerd. • Dit toestel dient onderaan in het rek gemonteerd te worden
  • Dell PowerConnect J-8216 | Hardware Guide - Page 233
    fondo del supporto. • Se il supporto è dotato di dispositivi stabilizzanti, installare tali dispositivi prima di montare o di procedere alla manutenzione dell'unità nel supporto. WARNING: Advarsel Unngå fysiske skader under montering eller reparasjonsarbeid på denne enheten når den befinner seg i et
  • Dell PowerConnect J-8216 | Hardware Guide - Page 234
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide • Ved montering av denne enheten i et kabinett som er delvis fylt, skal kabinettet lastes fra bunnen og opp med den tyngste komponenten nederst i kabinettet. • Hvis
  • Dell PowerConnect J-8216 | Hardware Guide - Page 235
    eller underhålls på ställningen. Related • General Safety Guidelines and Warnings for J-EX Series Switches on page 201 Documentation • Installation Instructions Warning for J-EX Series Switches on page 213 • Grounded Equipment Warning for J-EX Series Switches on page 219 • Mounting a J-EX8216
  • Dell PowerConnect J-8216 | Hardware Guide - Page 236
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide ¡Atención! Este equipo debe conectarse a tierra. Asegurarse de manufacturer. Dispose of used batteries according to the manufacturer's instructions. WARNING: Waarschuwing Er is ontploffingsgevaar als de batterij verkeerd vervangen
  • Dell PowerConnect J-8216 | Hardware Guide - Page 237
    18: Installation and Maintenance Safety Information équivalent, recommandée par le fabricant. Jeter les piles usagées conformément aux instructions du fabricant. WARNING: Warnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur durch den gleichen oder
  • Dell PowerConnect J-8216 | Hardware Guide - Page 238
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide WARNING: Waarschuwing Alvorens aan apparatuur te werken die met elektrische leidingen is verbonden, sieraden (inclusief ringen, kettingen en horloges) verwijderen. Metalen voorwerpen worden warm wanneer
  • Dell PowerConnect J-8216 | Hardware Guide - Page 239
    Chapter 18: Installation and Maintenance Safety Information e em contacto com a ligação à terra, podendo causar queimaduras graves ou ficarem soldados aos terminais. WARNING: ¡Atención! Antes de operar sobre equipos conectados a líneas de alimentación, quitarse las joyas (incluidos anillos, collares
  • Dell PowerConnect J-8216 | Hardware Guide - Page 240
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide WARNING: Advarsel Utfør aldri arbeid på systemet, eller koble kabler til eller fra systemet når det tordner eller lyner. WARNING: Aviso Não trabalhe no sistema ou ligue e desligue
  • Dell PowerConnect J-8216 | Hardware Guide - Page 241
    un locale che ecceda la temperatura ambientale massima di 40° C. Per evitare che la circolazione dell'aria sia impedita, lasciate uno spazio di almeno 15.2 cm di fronte alle aperture delle ventole. WARNING: Advarsel Unngå overoppheting av eventuelle rutere i switch Disse skal ikke brukes på steder
  • Dell PowerConnect J-8216 | Hardware Guide - Page 242
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide WARNING: Waarschuwing Dit produkt dient volgens alle landelijke wetten en voorschriften te Guidelines and Warnings for J-EX Series Switches on page 207 • Installation Instructions Warning for J-EX Series Switches on page 213 226
  • Dell PowerConnect J-8216 | Hardware Guide - Page 243
    Chapter 18: Installation and Maintenance Safety Information • Grounded Equipment Warning for J-EX Series Switches on page 219 227
  • Dell PowerConnect J-8216 | Hardware Guide - Page 244
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide 228
  • Dell PowerConnect J-8216 | Hardware Guide - Page 245
    CHAPTER 19 Power and Electrical Safety Information • General Electrical Safety Guidelines and Warnings for J-EX Series Switches on page 229 • Prevention of Electrostatic Discharge Damage on J-EX Series Switches on page 230 • AC Power Electrical Safety Guidelines for J-EX Series Switches on page 232
  • Dell PowerConnect J-8216 | Hardware Guide - Page 246
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide • Evaluated to the TN power system. • Canada-Canadian Operate the J-EX Series switch within marked electrical ratings and product usage instructions. • To ensure that the J-EX Series switch and peripheral equipment function
  • Dell PowerConnect J-8216 | Hardware Guide - Page 247
    Chapter 19: Power and Electrical Safety Information • Always use an ESD grounding strap when you are handling components that are subject to ESD damage, and make sure that it is in direct contact with your skin. If a grounding strap is not available, hold the component in its antistatic bag (see
  • Dell PowerConnect J-8216 | Hardware Guide - Page 248
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide AC Power Electrical Safety Guidelines for J-EX UNIT HAS MORE THAN ONE POWER SUPPLY CORD. DISCONNECT ALL POWER SUPPLY CORDS BEFORE SERVICING TO AVOID ELECTRIC SHOCK." "ATTENTION: CET APPAREIL COMPORTE PLUS D'UN CORDON D'ALIMENTATION.
  • Dell PowerConnect J-8216 | Hardware Guide - Page 249
    Chapter 19: Power and Electrical Safety Information AC Power Disconnection Warning for J-EX Series Switches WARNING: Before working on the switch or near power supplies, unplug all the power cords from an AC switch. Waarschuwing Voordat u aan een frame of in de nabijheid van voedingen werkt, dient u
  • Dell PowerConnect J-8216 | Hardware Guide - Page 250
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Multiple Power Supplies Disconnection Warning for J-EX Series Switches WARNING: For J-EX Series switches that have more than one power supply connection, you must ensure
  • Dell PowerConnect J-8216 | Hardware Guide - Page 251
    Chapter 19: Power and Electrical Safety Information In Case of Electrical Accident: Action to Take on a J-EX Series Switch If an electrical accident results in an injury, take the following actions in this order: 1. Use caution. Be aware of potentially hazardous conditions that could cause further
  • Dell PowerConnect J-8216 | Hardware Guide - Page 252
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide 236
  • Dell PowerConnect J-8216 | Hardware Guide - Page 253
    PART 8 Compliance Information • Compliance Information on page 239 237
  • Dell PowerConnect J-8216 | Hardware Guide - Page 254
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide 238
  • Dell PowerConnect J-8216 | Hardware Guide - Page 255
    • EN 60950-1:2001. Safety of Information Technology Equipment • EN 60825-1 Safety of Laser Products - Part 1: Equipment Classification, Requirements and User's Guide • EMC • FCC 47CFR Part 15 Class A (USA) • EN 55022 Class A Emissions (Europe) • ICES-003 Class A • VCCI Class A (Japan) • AS/NZS
  • Dell PowerConnect J-8216 | Hardware Guide - Page 256
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide • EN 61000-4-2 ESD • EN 61000-4-3 Radiated Immunity • EN connection. In some cases, the inside wiring associated with a single line individual service may be extended by means of a certified connector assembly. The customer should
  • Dell PowerConnect J-8216 | Hardware Guide - Page 257
    . This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference
  • Dell PowerConnect J-8216 | Hardware Guide - Page 258
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user
  • Dell PowerConnect J-8216 | Hardware Guide - Page 259
    Chapter 20: Compliance Information Declarations of Conformity for J-EX8216 Switches 243
  • Dell PowerConnect J-8216 | Hardware Guide - Page 260
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide Related • Agency Approvals for J-EX Series Switches on page 239 Documentation • Compliance Statements for EMC Requirements for J-EX Series Switches on page 240 • Compliance Statements
  • Dell PowerConnect J-8216 | Hardware Guide - Page 261
    PART 9 Index • Index on page 247 245
  • Dell PowerConnect J-8216 | Hardware Guide - Page 262
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide 246
  • Dell PowerConnect J-8216 | Hardware Guide - Page 263
    171 reducing radio frequency interference (RFI 65 cage nuts installing 104, 110 removing 154 calculating power consumption 85 Canadian EMC compliance 240 certification and training, Dell 185 247
  • Dell PowerConnect J-8216 | Hardware Guide - Page 264
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide chassis component serial Dell automated order-status service 185 Dell Enterprise Training and Certification 185 Dell online services 184 Dell product information 185 Dell Support 183 Dell support service, contacting 185 Dell
  • Dell PowerConnect J-8216 | Hardware Guide - Page 265
    switch 152 requirements 69 FRUs (field-replaceable units 25 FTP site, Dell 184 G grounding cable and lug attachment 129 connecting the switch to 129 specifications 59 H hardware configurations 7 hardware information, Dell support service 185 hardware overview 3 height, chassis 9 humidity
  • Dell PowerConnect J-8216 | Hardware Guide - Page 266
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide cable maintenance 178 handling 175 holding 176 161 RE module, redundant modules 161 SF module 164 online services, Dell 184 optical interface support 51 See also transceivers order status, checking 185 P packing
  • Dell PowerConnect J-8216 | Hardware Guide - Page 267
    190 slot numbers 16 powering off the switch 151 powering on the switch 133 problems with your order 185 product disposal 225 protective earthing terminal, connecting 130 R rack 225 rack-mounting 215 ramps 214 read installation instructions 213 TN power system 234 safety standards 239 251
  • Dell PowerConnect J-8216 | Hardware Guide - Page 268
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide sample hardware 7 seismic (earthquake), tested 185 storage, line cards 178 support customer, getting help 183 technical, requesting xv troubleshooting, requesting 198 support service, Dell, contacting 185 Switch Fabric (SF
  • Dell PowerConnect J-8216 | Hardware Guide - Page 269
    product disposal 225 rack-mounting requirements 215 ramp angle 214 read installation instructions 213 TN power system 234 warranty and repair limitations xv return procedure 185 websites, Dell 184 weight, chassis 9 width, chassis 9 wiring guidelines radio frequency interference (RFI 65
  • Dell PowerConnect J-8216 | Hardware Guide - Page 270
    Dell PowerConnect J-Series J-EX8216 Ethernet Switch Hardware Guide 254
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270

Dell PowerConnect J-Series
J-EX8216 Ethernet Switch
Hardware Guide
Published: 2010-10-05