Dell PowerConnect J-8216 Hardware Guide - Page 137
Calculating Power Requirements for a J-EX8216 Switch on If more power, LED is unlit
View all Dell PowerConnect J-8216 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 137 highlights
Chapter 9: Installing Switch Components Ensure the ejector levers are engaged in the horizontal ejector rail. If the levers are not engaged, push the module's faceplate just inside the hinges of the levers till the ejectors are engaged in the ejector rail. 6. Push both the ejector levers simultaneously towards the faceplate of the SF module until the levers are flush against the faceplate and are fully engaged. 7. Tighten the screws on each side of the SF module by turning them clockwise using the Phillips (+) screwdriver, number 2. Ensure that the SF module is fully seated in the chassis. 8. Verify that the SF module is installed correctly and functioning normally by checking the LEDs on the faceplate of the SF module. The ST LED and SF LED should be lit steady green a few minutes after the SF module is installed. If the ST LED is unlit, check whether there are enough power supplies installed. See "Calculating Power Requirements for a J-EX8216 Switch" on page 85. If more power supplies are needed, install additional power supplies. See "Installing an AC Power Supply in a J-EX8200 Switch" on page 114. If there are enough power supplies in the switch, remove and install the SF module again. See "Removing an SF Module from a J-EX8216 Switch" on page 165. If the ST LED or the SF LED is lit steady yellow, the SF module has failed. Remove the SF module and install a new one. See "Removing an SF Module from a J-EX8216 Switch" on page 165. 121