F.6 Mellanox Memory Free PCI-Express HCA (SDR) Specifications

Page 129 highlights

Safety: Environmental: IEC/EN 60950-1:2001 ETSI EN 300 019-2-2 IEC 60068-2- 64, 29, 32 F.6 Mellanox Memory Free PCI-Express HCA (SDR) Specifications The specifications listed below cover the Mellanox Mem-Free PCI-Express HCA (SDR). Physical Power and Environmental Protocol Support Regulatory Size: Air Flow: 10 Gb/s Connector: Voltage: Maximum Power: Temperature: InfiniBand: QoS: RDMA Support: EMC: Safety: 54mm x 102mm (2.13 in. x 4 in.) 200 LFM @55°C Amphenol InfiniBand MicroGigaCN 3.3V 4.2W 0° to 55° Celsius Auto-Negotiation (10 Gb/s, 2.5 Gb/s) 4 InfiniBand Virtual Lanes for the 4X port Yes FCC (47 CFR par 15, subpart B); ICES-003; VCCI; IEC/EN 55022; IEC/EN 55024; IEC/EN 61000 IEC/EN 60950 F.7 Mellanox Memory Free PCI-Express HCA (DDR) Specifications The specifications listed below cover the Mellanox Mem-Free PCI-Express HCA (DDR). Physical Power and Environmental Protocol Support Regulatory Size: Air Flow: 20 Gb/s Connector: Voltage: Maximum Power: Temperature: InfiniBand: QoS: RDMA Support: EMC: Safety: 54mm x 102mm (2.13 in. x 4 in.) 200 LFM @55°C Amphenol InfiniBand MicroGigaCN 3.3V 4.2W 0° to 55° Celsius Auto-Negotiation (10 Gb/s, 2.5 Gb/s) or (20 Gb/s, 5 Gb/s) 4 InfiniBand Virtual Lanes for the 4X port Yes FCC (47 CFR par 15, subpart B); ICES-003; VCCI; IEC/EN 55022; IEC/EN 55024; IEC/EN 61000 IEC/EN 60950 F.6 Mellanox Memory Free PCI-Express HCA (SDR) Specifications 129

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140

IEC/EN 60950-1:2001
Safety:
ETSI EN 300 019-2-2
IEC 60068-2- 64, 29, 32
Environmental:
F.6 Mellanox Memory Free PCI-Express HCA (SDR) Specifications
The specifications listed below cover the Mellanox Mem-Free PCI-Express HCA (SDR).
54mm x 102mm (2.13 in. x 4 in.)
Size:
Physical
200 LFM @55°C
Air Flow:
Amphenol InfiniBand MicroGigaCN
10 Gb/s Connector:
3.3V
Voltage:
Power and Environmental
4.2W
Maximum Power:
0° to 55° Celsius
Temperature:
Auto-Negotiation (10 Gb/s, 2.5 Gb/s)
InfiniBand:
Protocol Support
4 InfiniBand Virtual Lanes for the 4X port
QoS:
Yes
RDMA Support:
FCC (47 CFR par 15, subpart B); ICES-003;
EMC:
Regulatory
VCCI; IEC/EN 55022; IEC/EN 55024;
IEC/EN 61000
IEC/EN 60950
Safety:
F.7 Mellanox Memory Free PCI-Express HCA (DDR) Specifications
The specifications listed below cover the Mellanox Mem-Free PCI-Express HCA (DDR).
54mm x 102mm (2.13 in. x 4 in.)
Size:
Physical
200 LFM @55°C
Air Flow:
Amphenol InfiniBand MicroGigaCN
20 Gb/s Connector:
3.3V
Voltage:
Power and Environmental
4.2W
Maximum Power:
0° to 55° Celsius
Temperature:
Auto-Negotiation (10 Gb/s, 2.5 Gb/s) or
(20 Gb/s, 5 Gb/s)
InfiniBand:
Protocol Support
4 InfiniBand Virtual Lanes for the 4X port
QoS:
Yes
RDMA Support:
FCC (47 CFR par 15, subpart B); ICES-003;
EMC:
Regulatory
VCCI; IEC/EN 55022; IEC/EN 55024;
IEC/EN 61000
IEC/EN 60950
Safety:
F.6 Mellanox Memory Free PCI-Express HCA (SDR) Specifications