HP ProLiant DL170e HP ProLiant DL170e G6 Server Maintenance and Service Guide - Page 176

Table 23, Components, Description, Auxiliary power indicators

Page 176 highlights

Table 23 Hardware Specifications Item Status LED indicators Front panel Rear panel System board Power supply unit (PSU) Thermal solution Components • Power/system health status • UID status • NIC activity • LAN activity • LAN link status • Power/system health status • UID status • Auxiliary power indicators 1200 W redundant, power supply Four system fans Table 24 Physical Dimensions Item System board platform System board dimension Server dimensions (H x W x D) (with bezel) Server weight (approximate) Description ATX (Advanced Technology Extended) 17.935x6.5 in. 3.44 x 17.64 x 28.91 in. (8.74 x 44.81 x 73.43 cm) Maximum (all hard drives, power supplies, and processors installed) 82.00 lb (37.19 kg) Minimum (one hard drive, power supply, and processor installed) 40.00 lb (18.14 kg) Table 25 Environmental Specifications Item Thermal output (maximum operating) System inlet temperature Operating System inlet temperature Non-operating Relative humidity (non-condensing) Operating Description 392 W/hr 50° to 95° F (10° to 35° C) at sea level with an altitude derating of 1.8°F per every 1000 ft (1.0°C per every 305 m) above sea level to a maximum of 10,000 ft (3050 m), no direct sustained sunlight. Maximum rate of change is 18°F/hr (10°C/hr). The upper limit may be limited by the type and number of options installed. System performance may be reduced if operating with a fan fault or above 86°F (30°C). 40° to 140° F (-40° to 60° C) Maximum rate of change is 36°F/hr (20°C/hr). 10% to 85% relative humidity (Rh), 82.4°F (28°C) maximum wet bulb temperature, non-condensing. Physical and operating specifications 176

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180

Physical and operating specifications
176
Table 23
Hardware Specifications
Item
Components
Status LED indicators
Front panel
Rear panel
System board
Power/system health status
UID status
NIC activity
LAN activity
LAN link status
Power/system health status
UID status
Auxiliary power indicators
Power supply unit (PSU)
1200 W redundant, power supply
Thermal solution
Four system fans
Table 24
Physical Dimensions
Item
Description
System board platform
ATX (Advanced Technology Extended)
System board dimension
17.935x6.5 in.
Server dimensions (H x W x D)
(with bezel)
3.44 x 17.64 x 28.91 in. (8.74 x 44.81 x 73.43 cm)
Server weight (approximate)
Maximum (all hard drives, power supplies, and processors installed)
82.00 lb (37.19 kg)
Minimum (one hard drive, power supply, and processor installed)
40.00 lb (18.14 kg)
Table 25
Environmental Specifications
Item
Description
Thermal output (maximum operating)
392 W/hr
System inlet temperature
Operating
50° to 95° F (10° to 35° C) at sea level with an altitude derating of
1.8°F per every 1000 ft (1.0°C per every 305 m) above sea level to
a maximum of 10,000 ft (3050 m), no direct sustained sunlight.
Maximum rate of change is 18°F/hr (10°C/hr). The upper limit may
be limited by the type and number of options installed.
System
performance may be reduced if operating with a fan fault or above
86°F (30°C).
System inlet temperature
Non-operating
40° to 140° F (-40° to 60° C)
Maximum rate of change is 36°F/hr (20°C/hr).
Relative humidity (non-condensing)
Operating
10% to 85% relative humidity (Rh), 82.4°F (28°C) maximum wet
bulb temperature, non-condensing.