HP ProLiant DL170e HP ProLiant DL170e G6 Server Maintenance and Service Guide - Page 84
Reinstalling the PCIe riser cards, Removal and replacement procedures, Removing the 2U Riser Card
![]() |
View all HP ProLiant DL170e manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 84 highlights
Figure 51 Removing the 2U Riser Card Reinstalling the PCIe riser cards To install the 1U riser card on a 1U PCIe cage: 1. Align the two riser card mounting holes to the corresponding screw stand-offs on the PCIe cage. 2. Tighten the 2 screws that secure the riser card to the PCIe cage. Figure 52 Installing the 1U Riser Card on the 1U PCIe Cage To install the 2U riser card on a 2U PCIe cage: The following installing procedure uses the 3 x8-slot 2U riser card as example. 1. Align the four riser card mounting holes to the corresponding screw stand-offs on the 2U PCIe cage. 2. Tighten the 4 screws that secure the riser card to the 2U PCIe cage. Removal and replacement procedures 84
![](/manual_guide/products/hewlettpackard-proliant-dl170e-hp-proliant-dl170e-g6-server-maintenance-service-guide-4b5be1d/84.png)
Removal and replacement procedures
84
Figure 51
Removing the 2U Riser Card
Reinstalling the PCIe riser cards
To install the 1U riser card on a 1U PCIe cage:
1.
Align the two riser card mounting holes to the corresponding screw stand-offs on the PCIe cage.
2.
Tighten the 2 screws that secure the riser card to the PCIe cage.
Figure 52
Installing the 1U Riser Card on the 1U PCIe Cage
To install the 2U riser card on a 2U PCIe cage:
The following installing procedure uses the 3 x8-slot 2U riser card as example.
1.
Align the four riser card mounting holes to the corresponding screw stand-offs on the 2U PCIe
cage.
2.
Tighten the 4 screws that secure the riser card to the 2U PCIe cage.