HP ProLiant DL170e HP ProLiant DL170e G6 Server Maintenance and Service Guide - Page 64
System fan
![]() |
View all HP ProLiant DL170e manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 64 highlights
System fan The server has four system fans located in the fan cage. The figure below identifies the system fans by their device number and shows their corresponding cable connections. For more detailed information about system fan cable connections, see "Cable connections". The figure below identifies the system fans by their device numbers. Figure 23 System Fan Device Number Device number System Fan 1 System Fan 2 System Fan 3 System Fan 4 Connector System fan power cable P1 connector System fan power cable P2 connector System fan power cable P3 connector System fan power cable P4 connector System fans 1 to 4 are for the memory modules, processors, the PCIe slots and system chipsets. A new system fan can be installed to allow the server to operate properly in case a default system fan becomes defective. To remove the system fan: 1. Power down the server. 2. Disconnect the power cord(s). 3. Unlock the server if necessary and remove the top cover as described in the section "System covers". 4. Disconnect the fan cable from the corresponding fan power cable connector attached on the fan cage. 5. Lift the system fan away from the fan cage. Removal and replacement procedures 64
![](/manual_guide/products/hewlettpackard-proliant-dl170e-hp-proliant-dl170e-g6-server-maintenance-service-guide-4b5be1d/64.png)