Statement 2: CAUTION: When replacing the lithium battery, use only IBM Part Number 33F8354 or an equivalent type battery recommended by the manufacturer. If your system has a module containing a lithium battery, replace it only with the same module type made by the same manufacturer. The battery contains lithium and can explode if not properly used, handled, or disposed of. Do not: v Throw or immerse into water v Heat to more than 100°C (212°F) v Repair or disassemble Dispose of the battery as required by local ordinances or regulations. Complete the following steps to replace the battery: 1. Read the safety information beginning on page 197 and "Installation guidelines" on page 77. Follow any special handling and installation instructions supplied with the replacement battery. 2. Turn off the server and peripheral devices, and disconnect the power cords and all external cables from the server; then, open the cover (see "Opening the cover" on page 88 for details). 3. Remove fans 3 and 4 from the server (see "Replacing fan 3 or 4" on page 108 for details). 4. Remove the battery: a. Use one finger to press the top of the battery clip away from the battery. b. Lift and remove the battery from the socket. 5. Insert the new battery: a. Use one finger to press the top of the battery clip away from the battery. b. Press the battery into the socket until it clicks into place. Make sure that the battery clip holds the battery securely. 110 IBM xSeries 450 Type 8688: Hardware Maintenance Manual and Troubleshooting Guide