IBM 86884RX Maintenance Manual - Page 166
microprocessor
View all IBM 86884RX manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 166 highlights
Service Processor message 12V H Bus Fault 5V Fault Cable: Control Panel Not Present Cable: SCSI I2C cable not detected Cable: Service Processor Not Present Center Card Power Fault CPU 1-4 Over Temperature Failure reading I2C device. Check devices on bus x. Fan 1-4 Failure Fan 1-4 not detected Fan 1-4 Outside Recommended Speed Invalid Fan configuration Hard Drive 1-2 Fault Hard Drive 1-2 removal detected Integrated Systems Management Processor encountered failures upon starting Invalid CPU configuration CPU Card Machine Check TOR_MCK FRU/action 1. Disk drives 2. Disk drive backplane 3. I/O board 4. Power backplane 5. Power cables 6. Midplane board 1. Remove PCI adapters, and see if the problem remains. 2. I/O board. Cable to Light Path panel Cable to SCSI backplane 1. Remote Supervisor Adapter 2. I/O board 1. Midplane VRM 2. Midplane board 1. Check airflow blockage 2. Check fans 3. Microprocessor 1-4 1. Restart the server 2. I/O board 1. Check fan connection. 2. Fan. 1. Check fan connection. 2. Fan. 1. Check fan connection. 2. Fan. 1. Check fan connections. 2. Fans. Run diagnostics. 1. Hard disk drive 2. Run diagnostics 1. Remove ac power for 20 seconds, reconnect and reboot, and run diagnostics. 2. I/O board. Ensure microprocessor 1 is properly installed. 1. Run diagnostics. 2. Microprocessors. 3. Processor board. 4. Memory board. 5. I/O board. 6. Midplane board. 156 IBM xSeries 450 Type 8688: Hardware Maintenance Manual and Troubleshooting Guide